Microsoft Azure Stack HCI용 Dell EMC 솔루션을 배포 및 구성한 후 네트워크 스위치의 DCBX 작동 상태가 다운된 것으로 표시될 수 있습니다. 이는 다음을 실행하여 확인할 수 있습니다.
show interfaces tengigabitethernet x/y pfc detail. TOR1#show interfaces tengigabitethernet 1/5 pfc detail Interface TenGigabitEthernet 1/5 Admin mode is on Admin is enabled, Priority list is 3 Remote is disabled Local is enabled, Priority list is 3 Oper status is init PFC DCBX Oper status is Down Reason: Waiting for Peer State Machine Type is Symmetric TLV Tx Status is enabled PFC Link Delay 65535 pause quntams Application Priority TLV Parameters : -------------------------------------- FCOE TLV Tx Status is enabled ISCSI TLV Tx Status is disabled Local FCOE PriorityMap is 0x8 Local ISCSI PriorityMap is 0x0 1581 Input TLV pkts, 8649 Output TLV pkts, 121 Error pkts, 4495543 Pause Tx pkts, 374345 Pause Rx pkts 0 Input Appln Priority TLV pkts, 0 Output Appln Priority TLV pkts, 0 Error Appln Priority TLV Pkts
Dell EMC Storage Spaces Direct Ready Node에 대한 배포 지침의 일환으로 Mellanox CX4 LX 어댑터를 사용하여 RDMA용 RoCE v2를 사용하는 인프라스트럭처의 경우 호스트 OS에서 DCBX willing을 전역적으로 비활성화하고 네트워크 어댑터 DCBXMode를 Host in charge로 설정하는 것이 좋습니다. 이 구성에서는 DCBX 정보를 Dell EMC 네트워킹 스위치와 교환하는 다운스트림 엔터티가 없으므로 DCBX 작동 상태가 서버 측 포트에서 다운된 것으로 표시됩니다.