Kun Dell EMC -ratkaisu Microsoft Azure Stack HCI -ratkaisulle on otettu käyttöön ja määritetty, verkkokytkimien DCBX:n toimintatila saattaa näkyä laskussa. Tämä voidaan tarkistaa komennolla
show interfaces tengigabitethernet x/y pfc detail. TOR1#show interfaces tengigabitethernet 1/5 pfc detail Interface TenGigabitEthernet 1/5 Admin mode is on Admin is enabled, Priority list is 3 Remote is disabled Local is enabled, Priority list is 3 Oper status is init PFC DCBX Oper status is Down Reason: Waiting for Peer State Machine Type is Symmetric TLV Tx Status is enabled PFC Link Delay 65535 pause quntams Application Priority TLV Parameters : -------------------------------------- FCOE TLV Tx Status is enabled ISCSI TLV Tx Status is disabled Local FCOE PriorityMap is 0x8 Local ISCSI PriorityMap is 0x0 1581 Input TLV pkts, 8649 Output TLV pkts, 121 Error pkts, 4495543 Pause Tx pkts, 374345 Pause Rx pkts 0 Input Appln Priority TLV pkts, 0 Output Appln Priority TLV pkts, 0 Error Appln Priority TLV Pkts
Osana Dell EMC Storage Spaces Direct Ready Nodes -käyttöönotto-ohjeita suosittelemme poistamaan DCBX halukkaat maailmanlaajuisesti käytöstä isäntäkäyttöjärjestelmässä ja määrittämään DCBXModen vastuuisännäksi infrastruktuurin, joka käyttää RoCE v2:ta RDMA:lle Mellanox CX4 LX -sovittimien avulla. Tämän määrityksen avulla mikään ketjun loppupään taho ei vaihda DCBX-tietoja Dell EMC -verkkokytkimen kanssa, joten DCBX:n toimintatila näkyy alaspäin palvelimeen päin olevissa porteissa.