Summary: Dell PowerEdge R750 and R7525 servers that are configured with a rear 4x2.5" hard drive backplane may report fan errors in the system event and lifecycle logs.

This article applies to   This article does not apply to 

Symptoms

Dell PowerEdge R750 and R7525 servers that are configured with rear 4x2.5" hard drive backplane are equipped with three additional rear system fans (7,8,9). Under normal system operation, these fans may repeatedly report that they have been removed and reinserted into the server. These error events are recorded in both the System Event Logs (SEL) and iDRAC9 Lifecycle Logs. 

Onsite end users can visually identify when the rear 4x2.5" hard drive backplane is present by checking the back of the server for the 2.5" drive slots in the upper left third of server. Seer the image below to identify the 4x2.5" backplane cage. 
R750-Rear-Image.png
Remote end users can identify when the rear 4x2.5" hard drive backplane is present through the iDRAC9 web user interface. Go to Storage > Overview > Enclosures. Expand available enclosure details and check for the Enclosure Location = Rear. 
 
Storage-RearBP.png

Systems exhibiting this issue may cycle through events indicating that the rear fans 7-9 are missing and approximately five seconds later are inserted. These FAN0029 and FAN0028 events are recorded in the SEL and Lifecycle Log like the examples below. 

System event log example:
 
2022-02-15 01:32:10        3076        Fan 7A is either removed, incorrectly installed, or not present.
2022-02-15 01:32:10        3077        Fan 8A is either removed, incorrectly installed, or not present.
2022-02-15 01:32:10        3078        Fan 9A is either removed, incorrectly installed, or not present.

2022-02-1501:32:15        3079        Fan 7A inserted.
2022-02-1501:32:15        3080        Fan 8A inserted.
2022-02-1501:32:15        3081        Fan 9A inserted.
 
Lifecycle log example:
 
2022-02-15 01:32:15        3324        FAN0029        Fan 7A is either removed, incorrectly installed, or not present.
2022-02-15 01:32:28        3325        FAN0029        Fan 8A is either removed, incorrectly installed, or not present.
2022-02-15 01:32:29        3326        FAN0029        Fan 9A is either removed, incorrectly installed, or not present.

2022-02-1501:32:30        3327        FAN0028        Fan 7A is inserted.
2022-02-1501:32:31        3328        FAN0028        Fan 8A is inserted.
2022-02-1501:32:32        3329        FAN0028        Fan 9A is inserted.

Also, the lifecycle logs may contain Fan RPM events (FAN0000, FAN0005) and Fan Redundancy events (RDU0001, RDU0002).
 
2022-02-1501:38:55        3413        RDU0001        The fans are redundant.
2022-02-1501:38:54        3412        FAN0005        Fan 9A RPM is within range.
2022-02-15 01:38:54        3411        FAN0000        Fan 9A RPM is less than the lower warning threshold.
2022-02-1501:38:53        3410        FAN0005        Fan 8A RPM is within range.
2022-02-15 01:38:52        3409        FAN0000        Fan 8A RPM is less than the lower warning threshold.
2022-02-1501:38:52        3408        FAN0005        Fan 7A RPM is within range.
2022-02-15 01:38:51        3407        FAN0000        Fan 7A RPM is less than the lower warning threshold.
2022-02-15 01:38:51        3406        RDU0002        Fan redundancy is lost.

Cause

The iDRAC9 queries the system fans for RPM readings every five seconds. When these cycles of events occur in rapid succession, the iDRAC is misinterpreting some returned data bytes as errors leading to the false "removed" error messages. On the following query from the iDRAC, the fan and iDRAC correctly sync leading to the "inserted" messages within logs.

Resolution

Dell iDRAC9 firmware version 5.10.10.52 (April 2022) addresses mishandling of these returned RPM responses. An upgrade to this version should address the issue.

Affected Products

iDRAC9, iDRAC9 - 4.xx Series, iDRAC9 - 5.xx Series, PowerEdge R750, PowerEdge R7525
Article Properties
Article Number: 000197000
Article Type: Solution
Last Modified: 05 Sept 2022
Version:  5
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.
Article Properties
Article Number: 000197000
Article Type: Solution
Last Modified: 05 Sept 2022
Version:  5
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.