Alert ID | XMS_SSD_DIEH_ACTION_STATE_MARKED_FAIL |
Alert Text | Drive in bus enclosure slot has failed. |
Error Code | 0x00307302 |
Description | |
Resolution | Cause The drive has failed due to exceeding error thresholds. Solution The drive needs to be replaced. It is recommended to contact Technical Support so they can review the underlying cause of the error to determine the best course of action. |
Alert ID | XMS_SSD_DIEH_ACTION_STATE_DATA_TRACED |
Alert Text | Drive in bus enclosure slot associated data have been resulted. |
Error Code | 0x00307303 |
Description | |
Resolution | Cause A drive event has occurred that triggered the collection of vendor specific information from the affected drive. Solution A Data Collect should be taken from the system to assist in the resolution of this issue. To perform data collection using "PowerStore Manager go to Settings -> Support: Support Materials -> Start Collection." After the data collection completes, contact Technical Support so they can review the underlying cause of the error to determine the best course of action. |
Alert ID | XMS_SSD_DIEH_ACTION_STATE_REPLACE |
Alert Text | Drive in bus enclosure slot needs replacement. |
Error Code | 0x00307304 |
Description | The drive has failed due to exceeding error thresholds. |
Resolution | The drive needs to be replaced. It is recommended to contact Technical Support so they can review the underlying cause of the error to determine the best course of action. |
Alert ID | XMS_SSD_LINK1_HEALTH_LEVEL_5_MAJOR XMS_SSD_LINK2_HEALTH_LEVEL_5_MAJOR |
Alert Text | Cluster diagnostics detected a major problem in link 1 of drive in bus enclosure slot. Cluster diagnostics detected a major problem in link 2 of drive in bus enclosure slot. |
Error Code | 0x00306E05 0x00306F05 |
Description | As long as the other Node link is working as expected or other link is functional the impact on cluster is minimal. |
Resolution | Cause Each Drive has a Link per Node/LCC. This event signifies that one of the Links is down. Solution Cluster performance may be degraded. This problem could be caused by the Drive or one of the Nodes/LCC's. The recommendation is to replace the Drive to see if that resolves the issue. It is recommended to contact Technical Support so they can review the underlying cause of the error to determine the best course of action. |
Alert ID | XMS_SSD_DIAGNOSTIC_HEALTH_LEVEL_3_WARNING |
Alert Text | Diagnostics detected a minor problem for drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot). |
Error Code | 0x00306d03 |
Description | Indicates that a SMART warning was detected, or IO error detected. |
Resolution | As long as all other drives are healthy, and there is still free space to rebuild if another drive fails the immediate impact on the cluster is minimal. It is recommended to contact Technical Support so they can review the underlying cause of the error to determine the best course of action. |
Alert ID | XMS_SSD_DIAGNOSTIC_HEALTH_LEVEL_4_MINOR |
Alert Text | Diagnostics detected a problem for drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot). |
Error Code | 0x00306d04 |
Description | A SMART 5D error has been detected. |
Resolution | As long as all other drives are healthy, and there is still free space to rebuild if another drive fails the immediate impact on the cluster is minimal. The drive needs to be replaced. Follow the relevant Replace a faulted drive procedure in the Dell PowerStore Installation and Service Guide. |
Alert ID | XMS_SSD_LINK1_HEALTH_LEVEL_3_WARNING XMS_SSD_LINK2_HEALTH_LEVEL_3_WARNING |
Alert Text | Cluster diagnostics detected a minor problem in link 1 of drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot). Cluster diagnostics detected a minor problem in link 2 of drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot). |
Error Code | 0x00306e03 0x00306f03 |
Description | As long as the other Node link is working as expected or the other link is functional the impact on cluster is minimal. Cluster performance may be degraded. |
Resolution | It is recommended to contact Technical Support so they can review the underlying cause of the error to determine the best course of action. |
Alert ID | XMS_SSD_LINK1_HEALTH_LEVEL_4_MINOR XMS_SSD_LINK2_HEALTH_LEVEL_4_MINOR |
Alert Text | Cluster diagnostics detected a problem in link 1 of drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot). Cluster diagnostics detected a problem in link 2 of drive in bus %(bus_num) enclosure %(encl_num) slot %(enclosure_slot). |
Error Code | 0x00306e04 0x00306f04 |
Description | As long as the other Node link is working as expected or the other link is functional the impact on cluster is minimal. Cluster performance may be degraded. |
Resolution | It is recommended to contact Technical Support so they can review the underlying cause of the error to determine the best course of action. |