------------------------------------ ERROR - Critical System Memory Event ------------------------------------ Node = Nodes Extra = {'Nodes': {'169.254.1.1': ['Memory #0x02 - Uncorrectable ECC (UnCorrectable ECC | DIMMB1) (06/10/2023 08:45:16)', 'Memory #0x03 - Uncorrectable ECC (UnCorrectable ECC | DIMMB1) (06/10/2023 08:45:16)', 'Memory Mmry ECC Sensor - Correctable ECC (11/26/2015 12:38:51)']}} RAP = RAP163 Solution = KB 215723 Timestamp = 2023-07-10_170539 PSNT = CKMXXXXXXXXXXX @ 4.8-92.0
Befehl: (Remote-Befehl)
# sudo ipmitool -H <iDrac IP> -U root -P passwd -I lanplus sel elist
Befehl: (Lokaler Node)
# sudo ipmitool sel elist
Beispiel:
admin@node1:~> sudo ipmitool -H 192.XXX.2XX.107 -U root -P passwd -I lanplus sel elist 1 | 12/04/2021 | 07:29:19 | Event Logging Disabled SEL | Log area reset/cleared | Asserted 2 | 12/29/2021 | 23:00:29 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted 3 | 01/26/2022 | 11:44:08 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted 4 | 08/03/2022 | 18:31:45 | Power Supply PS Redundancy | Redundancy Lost | Asserted 5 | 08/03/2022 | 18:31:48 | Power Supply Status | Power Supply AC lost | Asserted 6 | 08/03/2022 | 18:43:14 | Power Supply Status | Power Supply AC lost | Deasserted 7 | 08/03/2022 | 18:43:22 | Power Supply PS Redundancy | Fully Redundant | Asserted 8 | 08/03/2022 | 18:51:27 | Power Supply PS Redundancy | Redundancy Lost | Asserted 9 | 08/03/2022 | 18:51:27 | Power Supply Status | Power Supply AC lost | Asserted a | 08/03/2022 | 19:02:03 | Power Supply Status | Power Supply AC lost | Deasserted b | 08/03/2022 | 19:02:14 | Power Supply PS Redundancy | Fully Redundant | Asserted c | 01/19/2023 | 05:38:27 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted d | 02/06/2023 | 02:10:25 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted e | 03/02/2023 | 17:12:15 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted f | 05/09/2023 | 15:56:41 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC | DIMMA1) | Asserted 10 | 05/09/2023 | 17:16:16 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted 11 | 05/09/2023 | 20:57:41 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC | DIMMA1) | Asserted 12 | 05/09/2023 | 20:59:25 | Unknown #0x2e | | Asserted 13 | 05/09/2023 | 20:59:25 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC | DIMMB1) | Asserted 14 | 05/11/2023 | 05:43:34 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted 15 | 06/10/2023 | 08:43:26 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC | DIMMA1) | Asserted 16 | 06/10/2023 | 08:45:16 | Unknown #0x2e | | Asserted 17 | 06/10/2023 | 08:45:16 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC | DIMMA1) | Asserted 18 | 06/10/2023 | 08:45:16 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC | DIMMB1) | Asserted
Befehl:
# sudo dmidecode -t memory | grep "Locator\|Size" | grep -v "Cache\|Volatile\|Cache\|Logical\|Bank"
Beispiel:
admin@node1:~> sudo dmidecode -t memory | grep "Locator\|Size" | grep -v "Cache\|Volatile\|Cache\|Logical\|Bank" Size: No Module Installed <-- DIMM is missing Locator: A1 Size: 16384 MB Locator: A2 Size: No Module Installed Locator: A3 Size: No Module Installed Locator: A4 Size: No Module Installed Locator: A5 Size: No Module Installed Locator: A6 Size: No Module Installed Locator: A7 Size: No Module Installed Locator: A8 Size: 16384 MB Locator: B1 Size: 16384 MB Locator: B2 Size: No Module Installed Locator: B3 Size: No Module Installed Locator: B4
Beispiel – Löschen des Systemereignisprotokolls (SEL):
Fragen Sie den iDRAC ab, um das Systemereignisprotokoll abzurufen, und bestätigen Sie, dass der Fehler in der Ausgabe vorhanden ist.
Denken Sie daran, bevor Sie das SEL löschen, nach anderen Fehlern zu suchen, die behoben werden müssen. Speichern Sie das Protokoll auch unter /var/log/hardware
wie beschrieben in KB 49569
.
In diesem Beispiel entspricht 192.168.219.101 der iDRAC-IP von Node 1:
admin@provo~> ipmitool -I lanplus -H 192.168.219.101 -U root -P passwd sel list 1 | 01/06/2022 | 04:34:58 | Event Logging Disabled #0x72 | Log area reset/cleared | Asserted 2 | 02/03/2022 | 17:15:21 | Physical Security #0x73 | General Chassis intrusion () | Asserted 3 | 02/03/2022 | 17:15:28 | Physical Security #0x73 | General Chassis intrusion () | Deasserted 4 | 08/18/2023 | 01:44:01 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC | DIMMA1) | Asserted
Löschen Sie das SEL:
admin@provo:~> ipmitool -I lanplus -H 192.168.219.101 -U root -P passwd sel clear Clearing SEL. Please allow a few seconds to erase.
Überprüfen Sie, ob die Liste gelöscht wurde:
admin@provo~> ipmitool -I lanplus -H 192.168.219.101 -U root -P passwd sel list 1 | 08/30/2023 | 12:56:55 | Event Logging Disabled #0x72 | Log area reset/cleared | Asserted