ECS: xDoctor: RAP163: Kritisches Systemspeicherereignis

Summary: Es ist ein kritisches Systemspeicherereignis aufgetreten, das überprüft und ausgetauscht werden muss.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

xDoctor meldet ein kritisches Systemspeicherereignis, das überprüft werden muss.
------------------------------------
ERROR - Critical System Memory Event
------------------------------------
Node      = Nodes
Extra     = {'Nodes': {'169.254.1.1': ['Memory #0x02 - Uncorrectable ECC (UnCorrectable ECC |  DIMMB1) (06/10/2023 08:45:16)', 'Memory #0x03 - Uncorrectable ECC (UnCorrectable ECC |  DIMMB1) (06/10/2023 08:45:16)', 'Memory Mmry ECC Sensor - Correctable ECC (11/26/2015 12:38:51)']}}
RAP       = RAP163
Solution  = KB 215723
Timestamp = 2023-07-10_170539
PSNT      = CKMXXXXXXXXXXX @ 4.8-92.0

Cause

HINWEIS: Wenn eines der DIMMs fehlt oder ein nicht korrigierbares Ereignis in den Systemereignisprotokollen (SEL) angezeigt wird, müssen die DIMMs ausgetauscht werden.
  1. Überprüfen Sie die SEL-Protokolle, um zu bestätigen, dass nicht korrigierbare Fehler auf dem Node vorhanden sind.

Befehl: (Remote-Befehl)

# sudo ipmitool -H <iDrac IP> -U root -P passwd -I lanplus sel elist

Befehl: (Lokaler Node)

# sudo ipmitool sel elist

Beispiel:

admin@node1:~> sudo ipmitool -H 192.XXX.2XX.107 -U root -P passwd -I lanplus sel elist
   1 | 12/04/2021 | 07:29:19 | Event Logging Disabled SEL | Log area reset/cleared | Asserted
   2 | 12/29/2021 | 23:00:29 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted
   3 | 01/26/2022 | 11:44:08 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted
   4 | 08/03/2022 | 18:31:45 | Power Supply PS Redundancy | Redundancy Lost | Asserted
   5 | 08/03/2022 | 18:31:48 | Power Supply Status | Power Supply AC lost | Asserted
   6 | 08/03/2022 | 18:43:14 | Power Supply Status | Power Supply AC lost | Deasserted
   7 | 08/03/2022 | 18:43:22 | Power Supply PS Redundancy | Fully Redundant | Asserted
   8 | 08/03/2022 | 18:51:27 | Power Supply PS Redundancy | Redundancy Lost | Asserted
   9 | 08/03/2022 | 18:51:27 | Power Supply Status | Power Supply AC lost | Asserted
   a | 08/03/2022 | 19:02:03 | Power Supply Status | Power Supply AC lost | Deasserted
   b | 08/03/2022 | 19:02:14 | Power Supply PS Redundancy | Fully Redundant | Asserted
   c | 01/19/2023 | 05:38:27 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted
   d | 02/06/2023 | 02:10:25 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted
   e | 03/02/2023 | 17:12:15 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted
   f | 05/09/2023 | 15:56:41 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC |  DIMMA1) | Asserted
  10 | 05/09/2023 | 17:16:16 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted
  11 | 05/09/2023 | 20:57:41 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC |  DIMMA1) | Asserted
  12 | 05/09/2023 | 20:59:25 | Unknown #0x2e |  | Asserted
  13 | 05/09/2023 | 20:59:25 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC |  DIMMB1) | Asserted
  14 | 05/11/2023 | 05:43:34 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted
  15 | 06/10/2023 | 08:43:26 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC |  DIMMA1) | Asserted
  16 | 06/10/2023 | 08:45:16 | Unknown #0x2e |  | Asserted
  17 | 06/10/2023 | 08:45:16 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC |  DIMMA1) | Asserted
  18 | 06/10/2023 | 08:45:16 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC |  DIMMB1) | Asserted
  1. Überprüfen Sie, ob DIMMs aufgrund des Ereignisses fehlen.

Befehl:

# sudo dmidecode -t memory | grep "Locator\|Size" | grep -v "Cache\|Volatile\|Cache\|Logical\|Bank"

Beispiel:

admin@node1:~> sudo dmidecode -t memory | grep "Locator\|Size" | grep -v "Cache\|Volatile\|Cache\|Logical\|Bank"
        Size: No Module Installed <-- DIMM is missing
        Locator: A1
        Size: 16384 MB
        Locator: A2
        Size: No Module Installed
        Locator: A3
        Size: No Module Installed
        Locator: A4
        Size: No Module Installed
        Locator: A5
        Size: No Module Installed
        Locator: A6
        Size: No Module Installed
        Locator: A7
        Size: No Module Installed
        Locator: A8
        Size: 16384 MB
        Locator: B1
        Size: 16384 MB
        Locator: B2
        Size: No Module Installed
        Locator: B3
        Size: No Module Installed
        Locator: B4

Resolution

Erfassen Sie die Ausgaben aus den obigen Befehlen und öffnen Sie einen Service-Request mit Verweis auf KB 215723, um das Server-DIMM für den Austausch zu überprüfen. 


Wenn das DIMM erfolgreich ersetzt wurde, erfordert xDoctor-Version 4.8.92.0 oder höher das Löschen des SEL auf dem betroffenen Node. Es werden keine weiteren Warnmeldungen zu diesem Protokolleintrag angezeigt.


Beispiel – Löschen des Systemereignisprotokolls (SEL):

Fragen Sie den iDRAC ab, um das Systemereignisprotokoll abzurufen, und bestätigen Sie, dass der Fehler in der Ausgabe vorhanden ist. 

Denken Sie daran, bevor Sie das SEL löschen, nach anderen Fehlern zu suchen, die behoben werden müssen. Speichern Sie das Protokoll auch unter /var/log/hardware wie beschrieben in KB 49569.

In diesem Beispiel entspricht 192.168.219.101 der iDRAC-IP von Node 1:

admin@provo~> ipmitool -I lanplus -H 192.168.219.101 -U root -P passwd sel list
   1 | 01/06/2022 | 04:34:58 | Event Logging Disabled #0x72 | Log area reset/cleared | Asserted
   2 | 02/03/2022 | 17:15:21 | Physical Security #0x73 | General Chassis intrusion () | Asserted
   3 | 02/03/2022 | 17:15:28 | Physical Security #0x73 | General Chassis intrusion () | Deasserted
   4 | 08/18/2023 | 01:44:01 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC |  DIMMA1) | Asserted


  Löschen Sie das SEL: 

admin@provo:~> ipmitool -I lanplus -H 192.168.219.101 -U root -P passwd sel clear
Clearing SEL.  Please allow a few seconds to erase.


Überprüfen Sie, ob die Liste gelöscht wurde:

admin@provo~> ipmitool -I lanplus -H 192.168.219.101 -U root -P passwd sel list
   1 | 08/30/2023 | 12:56:55 | Event Logging Disabled #0x72 | Log area reset/cleared | Asserted
 

Affected Products

ECS Appliance Gen 3

Products

ECS Appliance
Article Properties
Article Number: 000215723
Article Type: Solution
Last Modified: 30 May 2024
Version:  7
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.