ECS: xDoctor: RAP163: Kritisk systemminnehendelse

Summary: Det har oppstått en kritisk systemminnehendelse som må gjennomgås og byttes ut DIMM.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

xDoctor rapporterer en kritisk systemminnehendelse som trenger gjennomgang.
------------------------------------
ERROR - Critical System Memory Event
------------------------------------
Node      = Nodes
Extra     = {'Nodes': {'169.254.1.1': ['Memory #0x02 - Uncorrectable ECC (UnCorrectable ECC |  DIMMB1) (06/10/2023 08:45:16)', 'Memory #0x03 - Uncorrectable ECC (UnCorrectable ECC |  DIMMB1) (06/10/2023 08:45:16)', 'Memory Mmry ECC Sensor - Correctable ECC (11/26/2015 12:38:51)']}}
RAP       = RAP163
Solution  = KB 215723
Timestamp = 2023-07-10_170539
PSNT      = CKMXXXXXXXXXXX @ 4.8-92.0

Cause

MERK: Hvis noen av DIMM-ene mangler eller en ikke-korrigerbar hendelse vises i systemhendelsesloggene (SEL), må DIMM-ene byttes ut.
  1. Kontroller SEL-logger for å bekrefte at det er feil som ikke kan rettes opp på noden.

Kommando: (Ekstern kommando)

# sudo ipmitool -H <iDrac IP> -U root -P passwd -I lanplus sel elist

Kommando: (Lokal node)

# sudo ipmitool sel elist

Eksempel:

admin@node1:~> sudo ipmitool -H 192.XXX.2XX.107 -U root -P passwd -I lanplus sel elist
   1 | 12/04/2021 | 07:29:19 | Event Logging Disabled SEL | Log area reset/cleared | Asserted
   2 | 12/29/2021 | 23:00:29 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted
   3 | 01/26/2022 | 11:44:08 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted
   4 | 08/03/2022 | 18:31:45 | Power Supply PS Redundancy | Redundancy Lost | Asserted
   5 | 08/03/2022 | 18:31:48 | Power Supply Status | Power Supply AC lost | Asserted
   6 | 08/03/2022 | 18:43:14 | Power Supply Status | Power Supply AC lost | Deasserted
   7 | 08/03/2022 | 18:43:22 | Power Supply PS Redundancy | Fully Redundant | Asserted
   8 | 08/03/2022 | 18:51:27 | Power Supply PS Redundancy | Redundancy Lost | Asserted
   9 | 08/03/2022 | 18:51:27 | Power Supply Status | Power Supply AC lost | Asserted
   a | 08/03/2022 | 19:02:03 | Power Supply Status | Power Supply AC lost | Deasserted
   b | 08/03/2022 | 19:02:14 | Power Supply PS Redundancy | Fully Redundant | Asserted
   c | 01/19/2023 | 05:38:27 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted
   d | 02/06/2023 | 02:10:25 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted
   e | 03/02/2023 | 17:12:15 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted
   f | 05/09/2023 | 15:56:41 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC |  DIMMA1) | Asserted
  10 | 05/09/2023 | 17:16:16 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted
  11 | 05/09/2023 | 20:57:41 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC |  DIMMA1) | Asserted
  12 | 05/09/2023 | 20:59:25 | Unknown #0x2e |  | Asserted
  13 | 05/09/2023 | 20:59:25 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC |  DIMMB1) | Asserted
  14 | 05/11/2023 | 05:43:34 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted
  15 | 06/10/2023 | 08:43:26 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC |  DIMMA1) | Asserted
  16 | 06/10/2023 | 08:45:16 | Unknown #0x2e |  | Asserted
  17 | 06/10/2023 | 08:45:16 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC |  DIMMA1) | Asserted
  18 | 06/10/2023 | 08:45:16 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC |  DIMMB1) | Asserted
  1. Bekreft om det mangler DIMM-er på grunn av hendelsen.

Kommando:

# sudo dmidecode -t memory | grep "Locator\|Size" | grep -v "Cache\|Volatile\|Cache\|Logical\|Bank"

Eksempel:

admin@node1:~> sudo dmidecode -t memory | grep "Locator\|Size" | grep -v "Cache\|Volatile\|Cache\|Logical\|Bank"
        Size: No Module Installed <-- DIMM is missing
        Locator: A1
        Size: 16384 MB
        Locator: A2
        Size: No Module Installed
        Locator: A3
        Size: No Module Installed
        Locator: A4
        Size: No Module Installed
        Locator: A5
        Size: No Module Installed
        Locator: A6
        Size: No Module Installed
        Locator: A7
        Size: No Module Installed
        Locator: A8
        Size: 16384 MB
        Locator: B1
        Size: 16384 MB
        Locator: B2
        Size: No Module Installed
        Locator: B3
        Size: No Module Installed
        Locator: B4

Resolution

Samle utdataene fra kommandoene ovenfor, og åpne en serviceforespørsel med referanse til KB 215723 for å gjennomgå DIMM-en for serveren som må byttes ut. 


Hvis DIMM-en har blitt erstattet, krever xDoctor versjon 4.8.92.0 eller nyere at du sletter SEL på den berørte noden. Den stopper ytterligere varsler på denne loggoppføringen.


Eksempel – tømme systemhendelsesloggen (SEL):

Spør iDRAC for å hente systemhendelsesloggen, og kontroller at feilen finnes i utdataene. 

Husk at før du fjerner SEL, må du se etter andre feil som må løses. Lagre også loggen på /var/log/hardware Som beskrevet i KB 49569.

I dette eksemplet tilsvarer 192.168.219.101 iDRAC-IP-adressen til node 1:

admin@provo~> ipmitool -I lanplus -H 192.168.219.101 -U root -P passwd sel list
   1 | 01/06/2022 | 04:34:58 | Event Logging Disabled #0x72 | Log area reset/cleared | Asserted
   2 | 02/03/2022 | 17:15:21 | Physical Security #0x73 | General Chassis intrusion () | Asserted
   3 | 02/03/2022 | 17:15:28 | Physical Security #0x73 | General Chassis intrusion () | Deasserted
   4 | 08/18/2023 | 01:44:01 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC |  DIMMA1) | Asserted


  Tøm SEL: 

admin@provo:~> ipmitool -I lanplus -H 192.168.219.101 -U root -P passwd sel clear
Clearing SEL.  Please allow a few seconds to erase.


Kontroller at listen er fjernet:

admin@provo~> ipmitool -I lanplus -H 192.168.219.101 -U root -P passwd sel list
   1 | 08/30/2023 | 12:56:55 | Event Logging Disabled #0x72 | Log area reset/cleared | Asserted
 

Affected Products

ECS Appliance Gen 3

Products

ECS Appliance
Article Properties
Article Number: 000215723
Article Type: Solution
Last Modified: 30 May 2024
Version:  7
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.