Dell PowerEdge : iDRAC9 | RAC0182 - The iDRAC firmware was rebooted

摘要: This article will provide guidance on resolving the following error message displayed in iDRAC logs: "RAC0182 The iDRAC firmware was rebooted with the following reason: watchdog."

本文章適用於   本文章不適用於 

症狀

The following PowerEdge Servers and Dell Scalable Solutions (DSS) products may report a high frequency of Watchdog Timer Reset occurring on iDRAC9.

 

  • Dell Scalable Solutions (DSS)
    • DSS9600
    • DSS9620
    • DSS9630
    • DCS9650
    • DCS9750
  • PowerEdge-C
    • C6420
  • PowerEdge Modular
    • FC640 for FX2
    • M640 for M1000e
    • M640 for VRTX


 

The iDRAC9 will reboot and will be temporarily unavailable after this condition.  End-user environments that are utilizing remote monitoring software may receive alerts regarding iDRAC after the condition has occurred. The iDRAC Lifecycle Controller Log will record event RAC0182. During iDRAC reboot due to this condition, there is a possibility that the iDRAC may hang while re-initializing. This will lead to iDRAC and HOST becoming unresponsive and may require removing AC power to recover. 

 

SLN309655_en_US__1icon How to reset the Server is explained in this article .

 


The error message displayed is:
 

RAC0182 The iDRAC firmware was rebooted with the following reason: watchdog.


SLN309655_en_US__2iDRAC9-M640-WDT

 

 

原因

-

解析度

Solution

Dell EMC Engineering is aware of this issue and has released the iDRAC firmware 3.21.21.21.22 to solve this issue.
Download link of the latest iDRAC firmware version is available on this page. 

Systems require a reboot of the server after the update to effectively apply the firmware and resolve this condition.
M640 & FC640 require a physical or virtual reseat after applying the update. 

Performing the reboot or reseat allows the iDRAC memory to retrain and apply the fix during the next iDRAC cold boot.
 

SLN309655_en_US__3icon Note: The fix for DSS and modular platforms was originally included in iDRAC 3.15.17.15.  There is a condition that prevents the fix from correctly installing when updating from iDRAC9 3.15.15.15 directly to 3.18.18.18 or 3.21.21.21. iDRAC9 may continue to generate WatchDog Timer Resets after updating to 3.15.17.15. Please update to 3.21.21.22 to fix the issue.   

 

 

受影響的產品

DSS 9600, DSS 9620, DSS 9630, PowerEdge C6420, PowerEdge FC640, PowerEdge M640, PowerEdge M640 (for PE VRTX)