TPM PCR Validation Error causing BitLocker Recovery at Boot

Zhrnutie: This article provides information about Trusted Platform Module (TPM) Platform Configuration Register (PCR) Validation Error causing BitLocker Recovery at Boot.

Je možné, že tento článok bol preložený automaticky. Ak máte nejaké pripomienky ku kvalite prekladu, pošlite nám ich prostredníctvom formulára naspodku stránky.

Obsah článku


Symptómy


TPM PCR Validation Error causing BitLocker Recovery at Boot

 

GFX card computer will NOT use PCR7 binding and show as Binding not possible (0, 2, 4, 11).

Test Step:

  • Boot to Set up
  • Enable Secure Boot
  • Enable TPM
  • Boot to the operating system
  • Press Win + R "Cmd" run as administrator.
  • Input Command "manage-bde-protectors-get c:"

Device Manager

(Figure 1 - Device Manager)

 

PowerShell

(Figure 2 - PowerShell)

 

System Information

(Figure 3 - System Information)

 


Back to Top

 

Príčina

The dGPU (expandable cards) and its OROM/UEFI driver must be signed and measured through TPM PCR7. BIOS 1.6.0 to address the Security Vulnerability by implementing the security mechanism that follows TCG and MSFT’s requirement.

From the TCG side:

https://trustedcomputinggroup.org/wp-content/uploads/TCG_PCClient_PFP_r1p05_v23_pub.pdfExternal_Link_Icon

From the Operating System side:

In Microsoft’s own documentation on BitLocker Drive Encryption

BitLocker drive encryption in Windows 10 for OEMsExternal_Link_Icon

If the presence of expandable cards(Ex: GFX card) results in OROM UEFI drivers being loaded by UEFI BIOS during boot, then BitLocker will NOT use PCR7 binding.

https://docs.microsoft.com/en-us/troubleshoot/windows-server/deployment/pcr7-configuration-binding-not-possibleExternal_Link_Icon


Back to Top

 

Riešenie

According to Microsoft information, it is expected behavior, with no recovery plan.