文書番号: 000218471
Ce document explique comment vérifier l’autonomie de la batterie du bloc-batteries de secours (BBU) à des fins générales Si vous avez reçu un événement similaire à celui-ci :
Warning battery: The battery backup unit in chassis XXXXXXXXXXXXXX slot 2 has indicated cell End Of Life. Replace the battery backup unit as soon as possible.
Condition préalable:
Le cluster doit exécuter Health Check Framework 35 ou une version ultérieure et l’une des versions suivantes de OneFS :
# isi healthcheck version HealthCheck definition version: 35.0.0
# isi healthcheck run battery_test_status -v Queued evaluation to run: battery_test_status20231011T1718
isi healthcheck list | grep battery_test_status20231011T1718 Completed - Pass - /ifs/.ifsvar/modules/health-check/results/evaluations/battery_test_status20231011T1718
# cat /ifs/.ifsvar/modules/health-check/results/evaluations/battery_test_status20231011T1718 {"checklist_id": "battery_test_status", "delivery": [], "id": "battery_test_status20231011T1718", "overrides": [], "parameters": {}, "start_time": 1697044712.9590354} {"name": "battery_test_status", "parameters": {}, "status": "OK", "value": 100, "details": ["Battery 1 has 0 most recent test failures, threshold is 3", "Battery 1 Permanent fault status is False", "Battery 1 Capacity Degradation: 137600 mAh, 13.1%"], "node": "1", "passed": true} {"name": "battery_test_status", "parameters": {}, "status": "OK", "value": 100, "details": ["Battery 1 has 0 most recent test failures, threshold is 3", "Battery 1 Permanent fault status is False", "Battery 1 Capacity Degradation: 136100 mAh, 12.96%"], "node": "2", "passed": true} {"name": "battery_test_status", "parameters": {}, "status": "OK", "value": 100, "details": ["Battery 1 has 0 most recent test failures, threshold is 3", "Battery 1 Permanent fault status is False", "Battery 1 Capacity Degradation: 136850 mAh, 13.03%"], "node": "3", "passed": true} {"name": "battery_test_status", "parameters": {}, "status": "OK", "value": 100, "details": ["Battery 1 has 0 most recent test failures, threshold is 3", "Battery 1 Permanent fault status is False", "Battery 1 Capacity Degradation: 136400 mAh, 12.99%"], "node": "4", "passed": true} {"result":"PASS"}
isi upgrade cluster firmware devices | egrep "mongoose|bcc"
Le résultat de la commande se présente comme suit :
# isi upgrade cluster firmware devices| egrep "mongoose|bcc" MLKbem_mongoose ePOST 02.40 1-4 EPbcc_infinity ePOST 02.40 5-8
Le firmware de la BBU affecte la durée pour passer de 40 % à 50 % de dégradation.
Si la version du firmware BBU est 1.20, la batterie devrait prendre quatre mois pour passer d’une dégradation
de 40 % à 50 %.Si la version du firmware du BBU est 2.20 ou une version supérieure, la batterie doit prendre 12 mois pour passer de 40 % à 50 % de dégradation.
Si la version 1.20 ou antérieure du firmware BBU est installée et que vous souhaitez effectuer une mise à niveau vers le dernier firmware pris en charge, vous devez d’abord consulter ce document : Comment effectuer le test de la batterie avant la mise à niveau vers le package de firmware de nœud 10.3.9 ou 11.6
Isilon A200, Isilon A2000, Isilon F800, Isilon F810, Isilon Gen6, Isilon H400, Isilon H500, Isilon H5600, Isilon H600