I det här dokumentet beskrivs hur du kontrollerar batterilivslängden på batteribackupenheten (BBU) för allmänna ändamål eller om du har fått en händelse som liknar denna:
Warning battery: The battery backup unit in chassis XXXXXXXXXXXXXX slot 2 has indicated cell End Of Life. Replace the battery backup unit as soon as possible.
Förutsättning:
Klustret måste köra Health Check Framework 35 eller senare och någon av följande versioner av OneFS:
# isi healthcheck version HealthCheck definition version: 35.0.0
# isi healthcheck run battery_test_status -v Queued evaluation to run: battery_test_status20231011T1718
isi healthcheck list | grep battery_test_status20231011T1718 Completed - Pass - /ifs/.ifsvar/modules/health-check/results/evaluations/battery_test_status20231011T1718
# cat /ifs/.ifsvar/modules/health-check/results/evaluations/battery_test_status20231011T1718 {"checklist_id": "battery_test_status", "delivery": [], "id": "battery_test_status20231011T1718", "overrides": [], "parameters": {}, "start_time": 1697044712.9590354} {"name": "battery_test_status", "parameters": {}, "status": "OK", "value": 100, "details": ["Battery 1 has 0 most recent test failures, threshold is 3", "Battery 1 Permanent fault status is False", "Battery 1 Capacity Degradation: 137600 mAh, 13.1%"], "node": "1", "passed": true} {"name": "battery_test_status", "parameters": {}, "status": "OK", "value": 100, "details": ["Battery 1 has 0 most recent test failures, threshold is 3", "Battery 1 Permanent fault status is False", "Battery 1 Capacity Degradation: 136100 mAh, 12.96%"], "node": "2", "passed": true} {"name": "battery_test_status", "parameters": {}, "status": "OK", "value": 100, "details": ["Battery 1 has 0 most recent test failures, threshold is 3", "Battery 1 Permanent fault status is False", "Battery 1 Capacity Degradation: 136850 mAh, 13.03%"], "node": "3", "passed": true} {"name": "battery_test_status", "parameters": {}, "status": "OK", "value": 100, "details": ["Battery 1 has 0 most recent test failures, threshold is 3", "Battery 1 Permanent fault status is False", "Battery 1 Capacity Degradation: 136400 mAh, 12.99%"], "node": "4", "passed": true} {"result":"PASS"}
isi upgrade cluster firmware devices | egrep "mongoose|bcc"
Utdata från kommandot ser ut så här:
# isi upgrade cluster firmware devices| egrep "mongoose|bcc" MLKbem_mongoose ePOST 02.40 1-4 EPbcc_infinity ePOST 02.40 5-8
Den fasta BBU-programvaran påverkar hur lång tid det tar att gå från 40 % försämring till 50 % försämring.
Om version 1.20 av den fasta programvaran för BBU bör det ta fyra månader för batteriet att gå från en försämring
på 40 % till 50 %.Om version 2.20 eller senare av den fasta programvaran för BBU bör det ta 12 månader för batteriet att gå från 40 % till 50 % försämring.
Om version 1.20 eller äldre av den fasta programvaran för BBU är installerad och du vill uppgradera till den senaste fasta programvaran som stöds måste du först läsa igenom det här dokumentet: Så här utför du batteritestet innan du uppgraderar till paket 10.3.9 eller 11.6 med fast programvara för nod