Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

VNX:如何将相同的 CIFS 接口作为 NFS 连接到相同的 VDM

Summary: 只能通过 CLI 命令将相同的 CIFS 接口作为 NFS 连接到相同的 VDM。

This article may have been automatically translated. If you have any feedback regarding its quality, please let us know using the form at the bottom of this page.

Article Content


Instructions

连接到控制台 SSH。

要查看作为 CIFS 或 NFS 连接的接口,请应用以下命令:
$nas_server -i -v

示例:
migadmin@nla3v1stor003 ~]$ nas_server -i -v PROD_VDM
id = 1
name = PROD_VDM
acl = 0
type = vdm
server = server_2
rootfs = root_fs_vdm_PROD_VDM
I18N mode = UNICODE
mountedfs = Prod_Perf,Prod_Space,Prod_Perf_2,Prod_Perf_3
member_of =
status :
defined = enabled
actual = loaded, active
Interfaces to services mapping:
interface=Prodperf :cifs
interface=nl0123nas0001_390 :cifs
interface=nl0123nas0002_390 :cifs
interface=Prodspace :cifs nfs


上面的示例显示接口名称“nl0123nas0002_390”仅作为 CIFS 进行连接,而接口名称“Prodspace”作为 CIFS  NFS 进行连接。

要将相同的 CIFS 接口作为 NFS 进行连接,请应用以下命令:
$nas_server - vdm -attach

示例:
migadmin@nla3v1stor003 ~]$ nas_server -vdm PROD_VDM -attach nl0123nas0002_390
id = 1
name = PROD_VDM
acl = 0
type = vdm
server = server_2
rootfs = root_fs_vdm_PROD_VDM
I18N mode = UNICODE
mountedfs = Prod_Perf,Prod_Space,Prod_Perf_2,Prod_Perf_3
member_of =
status :
defined = enabled
actual = loaded, active
Interfaces to services mapping:
interface=Prodperf :cifs
interface=nl0123nas0001_390 :cifs
interface=nl0123nas0002_390 :cifs nfs
interface=Prodspace :cifs nfs

Article Properties


Affected Product

VNX1 Series, VNX2 Series, VNX5100, VNX5150, VNX5200, VNX5300, VNX5400, VNX5500, VNX5600, VNX5700

Product

VNX5800, VNX7500, VNX7600, VNX8000

Last Published Date

06 Jan 2022

Version

2

Article Type

How To