Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products

FluidFS Customer Notification: Controller fails to boot due to a drained clock battery

Summary: This article explains a situation where after a power outage the possibility exists for the clock to revert to zero-time-value and the next controller boot fails

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Resolution

Following a power outage or reboot, if the ToD (time of day) clock battery is drained, the clock reverts to zero-time-value and the next controller boot fails the FSCK phase.

This issue does not occur on the following applicable versions:

FS Series Platform

Version

Compellent FS8600

6.0.110054 and Higher

Equallogic FS7600 and FS7610

4.0.400005

The FSCK phase now runs despite the abnormal clock value.


If a controller is identified as not completing its boot process, review its status via local console connection.

Connect a KVM or connect a VGA monitor and USB keyboard to see the status of the console.

After post is completed, during the boot up sequence, you may see similar errors:

 

UNEXPECTED INCONSISTENCY; RUN fsck MANUALLY

Checking filesystems

Superblock last mount time ( <time>,

Now = <time> ) is in the future.

 

Give root password for maintenance

(or type Control-D to continue):

 

SLN310369_en_US__1image(4059)

 

If the above errors are seen, as a temporary workaround is to reseat the controller (or Control-D from this prompt) and enter the BIOS setup when prompted during post and set the time manually to be the correct time.
If the BIOS displays only a black screen and inaccessible, please contact Dell Technical support and reference internal article SLN304688.

 

 

SLN310369_en_US__2image(4060)

 

Once the time is set to the correct time, the controller will successfully boot. This change will not persist if the controller is rebooted again with a faulty coin cell battery.
Further remediation can be taken by Dell Technical Support to assist in replacing the faulty coin cell battery and upgrading the FluidFS firmware.

Please reference this article and internal article SLN304688

Affected Products

Dell Compellent FS8600, EqualLogic FS7600, EqualLogic FS7610
Article Properties
Article Number: 000143916
Article Type: Solution
Last Modified: 21 Feb 2021
Version:  4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.