Alert ID | RESOURCE_BALANCER_TIME_TO_FULL_CLUSTER_BELOW_MAJOR_THRESHOLD RESOURCE_BALANCER_TIME_TO_FULL_APPLIANCE_BELOW_MAJOR_THRESHOLD |
Alert Text | The cluster is projected to run out of space in %(ttf_days) days. The appliance %(object_id) is projected to run out of space in %(ttf_days) days. |
Error Code | (0x00A00301) (0x00A00401) |
Description | An appliance(s) within a PowerStore cluster or the entire cluster is running low on storage space. The customer is alerted daily until the issue is resolved to avoid running out of storage space entirely. When PowerStore runs out of storage space, it goes into "read-only" mode. |
Resolution | Cause Based on predictive analytics, an appliance(s) within a PowerStore cluster or the entire cluster is projected to run out of storage space within 14 days. There are three internal thresholds the system uses to determine when to alert the user:
Solution When a major alert is raised for an appliance that is predicted to run out of space, the alert details dialog window guides the user through a repair workflow.
The PowerStore Manager Repair Flow offers the following options:
Alternatively, the migration recommendation REST APIs can be used if Assisted Migration is desired using the REST API (/api/rest/migration_recommendation). Refer to the REST API Reference Guide for PowerStore in PowerStore Info Hub for additional information.
|
Alert ID | RESOURCE_BALANCER_TIME_TO_FULL_APPLIANCE_BELOW_MINOR_THRESHOLD RESOURCE_BALANCER_TIME_TO_FULL_CLUSTER_BELOW_MINOR_THRESHOLD |
Alert Text | Appliance %(object_id) is projected to run out of space in %(ttf_days) days. The cluster is projected to run out of space in %(ttf_days) days. |
Error Code | (0x00A00302) (0x00A00402) |
Description | An appliance(s) within a PowerStore cluster or the entire cluster is running low on storage space. The customer is alerted daily until the issue is resolved to avoid running out of storage space entirely. When PowerStore runs out of storage space, it goes into "read-only" mode. |
Resolution | Cause Based on predictive analytics, an appliance(s) within a PowerStore cluster or the entire cluster is projected to run out of storage space within 28 days. There are three internal thresholds the system uses to determine when to alert the user:
Solution When a minor alert is raised that a cluster or appliance is predicted to run out of space, consider one of the following:
|
Alert ID | RESOURCE_BALANCER_DISK_HIGH_WEAR_RATE_APPLIANCE_ABOVE_THRESHOLD |
Alert Text | System drives are experiencing high wear rates (more than 4% in 60 days) |
Error Code | 0x00A00601 |
Impact | Drive will be used until the drive fails or endurance is exhausted. |
Resolution | Solution: Contact Technical Support as soon as possible for assistance in resolving this issue. |