部署和設定適用於 Microsoft Azure Stack HCI 的 Dell EMC 解決方案後,您可能會看到網路交換器上的 DCBX 作業狀態可能顯示為「關閉」。您可以執行此驗證
show interfaces tengigabitethernet x/y pfc detail. TOR1#show interfaces tengigabitethernet 1/5 pfc detail Interface TenGigabitEthernet 1/5 Admin mode is on Admin is enabled, Priority list is 3 Remote is disabled Local is enabled, Priority list is 3 Oper status is init PFC DCBX Oper status is Down Reason: Waiting for Peer State Machine Type is Symmetric TLV Tx Status is enabled PFC Link Delay 65535 pause quntams Application Priority TLV Parameters : -------------------------------------- FCOE TLV Tx Status is enabled ISCSI TLV Tx Status is disabled Local FCOE PriorityMap is 0x8 Local ISCSI PriorityMap is 0x0 1581 Input TLV pkts, 8649 Output TLV pkts, 121 Error pkts, 4495543 Pause Tx pkts, 374345 Pause Rx pkts 0 Input Appln Priority TLV pkts, 0 Output Appln Priority TLV pkts, 0 Error Appln Priority TLV Pkts
在 Dell EMC Storage Spaces Direct Ready Nodes 部署指南中,若基礎結構使用 Mellanox CX4 LX 配接卡的 RDMA 使用 RoCE v2,我們建議在主機作業系統中全域停用 DCBX,並將網路配接卡 DCBX Mode 設定為「負責的主機」。使用此組態時,沒有下游實體與 Dell EMC 網路交換器 DCBX 資訊,因此在面對伺服器的連接埠上,DCBX 作業狀態會顯示為關閉。