Efter driftsättningen och konfigurationen av Dell EMC-lösningen för Microsoft Azure Stack HCI kan det hända att DCBX-driftsstatusen på nätverksswitcharna visas som nere. Detta kan verifieras genom att köra
show interfaces tengigabitethernet x/y pfc detail. TOR1#show interfaces tengigabitethernet 1/5 pfc detail Interface TenGigabitEthernet 1/5 Admin mode is on Admin is enabled, Priority list is 3 Remote is disabled Local is enabled, Priority list is 3 Oper status is init PFC DCBX Oper status is Down Reason: Waiting for Peer State Machine Type is Symmetric TLV Tx Status is enabled PFC Link Delay 65535 pause quntams Application Priority TLV Parameters : -------------------------------------- FCOE TLV Tx Status is enabled ISCSI TLV Tx Status is disabled Local FCOE PriorityMap is 0x8 Local ISCSI PriorityMap is 0x0 1581 Input TLV pkts, 8649 Output TLV pkts, 121 Error pkts, 4495543 Pause Tx pkts, 374345 Pause Rx pkts 0 Input Appln Priority TLV pkts, 0 Output Appln Priority TLV pkts, 0 Error Appln Priority TLV Pkts
Som en del av distributionsvägledningen för Dell EMC Storage Spaces Direct Ready Nodes, för infrastrukturer som använder RoCE v2 för RDMA med Mellanox CX4 LX-kort, rekommenderar vi att du inaktiverar DCBX Willing globalt i värdoperativsystemet och ställer in nätverkskortet DCBXMode till Ansvarig värd. Med den här konfigurationen finns det ingen nedströmsenhet som utbyter DCBX-informationen med Dell EMC-nätverksswitchen och därför visas DCBX-driftstatusen som nere på de serverriktade portarna.