Article Number: 000137657
This alert pertains to SCOS versions 7.1.20, 7.2.10, 7.2.11, and 7.2.30. It contains specific information related to system features and/or functionality.
Notification:
Dell EMC has identified a software issue that can cause data to not move to the desired location after a Storage Profile change is made to volumes that utilizes Deduplication and/or Compression. This issue will also cause excessive "Invalid previous cost" messages in the Storage Center system logs which could lead to an increased frequency of the system sending SupportAssist information back to Dell EMC.
Affected versions:
SCOS versions 7.1.20, 7.2.10, 7.2.11, and 7.2.30
Workaround:
There are three possible work arounds for this issue.
Resolution:
This will be resolved in SCOS versions 7.1.30, 7.2.31, 7.2.40, and 7.3.1.
10 Apr 2021
3
Solution