Isilon Gen6: Gen6 cluster shows event 'HW_INFINITY_I2C_FAULT' but nodes are up and running - Event ID: 900160007, 900160014

Summary: Gen6 clusters can sometimes show the event 'HW_INFINITY_I2C_FAULT' for multiple nodes even though all nodes are up and running. The event generally cancels after a few minutes, but may reoccur at a later time. ...

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Gen6 clusters can sometimes show the critical-level event 'HW_INFINITY_I2C_FAULT' for multiple nodes even though all nodes are up and running. The event generally cancels after a few minutes, but may reoccur at a later time. The event implies an I2C communication error has occurred, but this does not necessarily indicate any hardware failure has occurred. Outside of the event itself, you should not experience any adverse effects to your node or cluster. Given these I2C communications are often between two nodes, it is common to see this event on more than one node in a chassis.

Cause

An issue has been identified with the shipping firmware for the BMC component in certain Gen6 nodes that appears to be causing many of these error messages. The issue is given some relief in Gen6 BMC firmware 23.90 which was released in Node Firmware Package 10.2.1. Engineering is investigating further improvements to mitigate this issue. This issue is non-impactful; the node s redundant I2C buses should ensure that necessary system communication continues normally.

Resolution

The issue has been provided partial relief in Gen6 BMC firmware version 23.90, which was released in Node Firmware Package 10.2.1. For many clusters, this resolves these alerts entirely. This node firmware package also contains fixes for several other Gen6-specific issues. Improvements to prevent this event from sometimes being generated at the critical event level unnecessarily instead of at the warning level have also been released, and improvements were made to the firmware upgrade process in OneFS 8.1.0.4 and later. It is recommended that you upgrade the cluster to OneFS 8.1.0.4 or later, and Node Firmware Package 10.2.1 or later, in that order, during your next scheduled maintenance window, or at the earliest opportunity. If upgrading OneFS is not an option at this time, upgrading directly to Node Firmware Package 10.2.1 or later should still resolve most instances of this spurious error message.

Please Note: Upgrading node firmware and/or OneFS will require each node being upgraded to reboot at the end of its upgrade cycle - this is a required part of the upgrade process and cannot be avoided.

The latest Node Firmware Package and OneFS installation package, and their accompanying Release Notes documents, can be downloaded from the support.emc.com web site. Instructions for installing the firmware package and updating the cluster firmware, as well as instructions for updating OneFS, can be found in their respective Release Notes documents.

Affected Products

Isilon

Products

Isilon, Isilon A200, Isilon F800, Isilon Gen6, Isilon H400, Isilon H500, Isilon H600
Article Properties
Article Number: 000050378
Article Type: Solution
Last Modified: 24 Apr 2021
Version:  3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.