Dell PowerEdge R750 Installation and Service Manual

Installing the 2 x 2.5-inch rear drive module

Prerequisites

  1. Follow the safety guidelines listed in Safety instructions.
  2. Follow the procedure listed in Before working inside your system.
  3. If required, remove the air shroud.
  4. Remove the drives.
  5. Disconnect the cables from the rear drive module.
    NOTE:Refer cable routing topic for more information.

Steps

  1. Align the slot on the rear drive module with the guide on the system.
  2. Place the rear drive module on top of the riser until firmly seated.
  3. Using a Phillips #2 screwdriver, tighten the captive screws that secures the rear drive module to the system.
    Figure 1. Installing the 2 x 2.5-inch rear drive module
    This image shows Installing the rear drive cage.

Next steps

  1. Connect all the cables to the rear drive module.
  2. Install the drives.
  3. If removed, install the air shroud.
  4. Follow the procedure listed in After working inside your system.