Dell PowerEdge R630 Owner's Manual

PSU specifications

The PowerEdge R630 system supports up to two AC or DC redundant power supply units (PSUs).
Table 1. PSU specificationsFor 495 W AC, platinum power supply unit, the maximum heat dissipation is 1908 BTU/hr, frequency is 50/60 Hz, and voltage range is 100­240 V AC autoranging. For 750 W AC platinum PSU, the maximum heat dissipation is 2891 BTU/hr, frequency is 50/60 Hz, and voltage range is 100­240 V AC autoranging. For 750 W AC titanium PSU, the maximum heat dissipation is 2843 BTU/hr, frequency is 50/60 Hz, and voltage range is 200­240 V AC autoranging. For 1100 W AC platinum PSU, the maximum heat dissipation is 4100 BTU/hr, frequency is 50/60 Hz, and voltage range is 100-240 V AC autoranging. For 1100 W DC PSU, the maximum heat dissipation is 4416 BTU/hr and the voltage range is – (48­60) V DC. For 750 W DC platinum PSU, the maximum heat dissipation is 2902 BTU/hr, frequency is 50/60 Hz, and voltage range is 100­240 V AC and 240 DC. The 750 W DC PSU is applicable to China only.
PSU Class Heat dissipation (maximum) Frequency Voltage
495 W AC Platinum 1908 BTU/hr 50/60 Hz 100–240 V AC, autoranging
750 W AC Platinum 2891 BTU/hr 50/60 Hz 100–240 V AC, autoranging
750 W AC Titanium 2843 BTU/hr 50/60 Hz 200–240 V AC, autoranging
1100 W AC Platinum 4100 BTU/hr 50/60 Hz 100–240 V AC, autoranging
1100 W DC 4416 BTU/hr –(48–60) V DC
750 W DC (for China only) Platinum 2902 BTU/hr 50/60 Hz 100–240 V AC and 240 V DC
NOTE Heat dissipation is calculated by using the PSU wattage rating.
NOTE This system is also designed to connect to the IT power systems with a phase to phase voltage not exceeding 230 V.