Dell PowerEdge R760 Installation and Service Manual

Removing the BOSS-N1 module

The removal of the BOSS-N1 module from the Riser 1 and 4 x 2.5-inch rear drive module is similar.

Prerequisites

  1. Follow the safety guidelines listed in the Safety instructions.
  2. Follow the procedure listed in the Before working inside your system.

Steps

  1. Pull and lift the BOSS-N1 card carrier retention latch lock to open.
  2. Slide the BOSS-N1 card carrier out.
    Figure 1. Removing the BOSS-N1 card carrier
    Removing the BOSS-N1 card carrier
  3. Using the Phillips #1 screwdriver remove the M3 x 0.5 x 4.5 mm screw that secures the M.2 NVMe SSD to the BOSS-N1 card carrier.
  4. Slide the M.2 NVMe SSD out from the BOSS-N1 card carrier.
    Figure 2. Removing the M.2 NVMe SSD
    Removing the M.2 NVMe SSD
  5. Disconnect the BOSS-N1 power and signal cable from the system board.
  6. Using the Phillips #1 screwdriver remove the M3 x 0.5 x 4.5 mm screw that secures the BOSS-N1 module on Riser 1.
  7. Slide the BOSS-N1 module towards the front of the chassis and lift the module.
    Figure 3. Removing the BOSS-N1 module
    This image shows Removing the BOSS-N1 module
  8. Pull the blue tag to remove the BOSS-N1 signal cable from the BOSS-N1 module.
  9. Remove the BOSS-N1 power cable from the BOSS-N1 module.
    Figure 4. Removing the BOSS-N1 power and signal cable from the BOSS-N1 module
    Removing the BOSS power cable and BOSS signal cable from the BOSS-N1 module