메인 콘텐츠로 이동
  • 빠르고 간편하게 주문
  • 주문 보기 및 배송 상태 추적
  • 제품 목록을 생성 및 액세스
  • 회사 관리를 사용하여 Dell EMC 사이트, 제품 및 제품 수준 연락처를 관리하십시오.

Dell PowerEdge R760 Installation and Service Manual

Removing the 4 x 2.5-inch rear drive module

Prerequisites

  1. Follow the safety guidelines listed in Safety instructions.
  2. Follow the procedure listed in Before working inside your system.
  3. If required, remove the air shroud.
  4. Remove the drives.
  5. NOTE: If BOSS-N1 module is installed, make sure to disconnect the BOSS-N1 power cable and Signal cable before removing the 4 x 2.5-inch rear drive module. Removing the BOSS power cable and BOSS signal cable from the BOSS-N1 module
  6. Disconnect the cables from the rear drive module.
    NOTE:See cable routing section for more information.
Table 1. Rear drive bay slot numbersThe table shows information that is related to rear drive bay slot numbers.
Configurations with four rear drives Bay0 slot numbers Bay1 slot numbers
12 x 3.5-inch SAS/SATA + 4 x 2.5-inch SAS/SATA Slot 0, 1, 2 and 3 N/A
12 x 3.5-inch SAS/SATA + 4 x 2.5-inch NVMe Slot 0, 1, 2 and 3 N/A
24 x 2.5-inch SAS/SATA + 4 x 2.5-inch SAS/SATA N/A Slot 24, 25, 26 and 27
24 x 2.5-inch SAS/SATA + 4 x 2.5-inch NVMe Slot 0, 1, 2 and 3 N/A

Steps

  1. Using a Phillips #2 screwdriver, loosen the captive screws that secure the rear drive module to the system.
  2. Lift the rear drive module from the system.
    Figure 1. Removing the 4 x 2.5-inch rear drive module
    This image shows Removing the 4 x 2.5-inch rear drive module