Dell PowerEdge R760 Installation and Service Manual

Installing the EDSFF E3.S backplane module

Prerequisites

  1. Follow the safety guidelines listed in the Safety instructions.
  2. Follow the procedure listed in the Before working inside your system.
  3. Remove the front bezel.
  4. Remove the cooling fan cage assembly.
  5. Remove the drive backplane cover.
  6. If required, remove the air shroudor remove the GPU air shroud.
  7. Remove the EDSFF E3.S PERC module.
  8. Remove the EDSFF E3.S drives.
  9. Disconnect the cables, observe the cable routing.
    NOTE:See cable routing section; configuration 45 or 46 for more information.

Steps

  1. Align the guides on the EDSFF E3.S backplane module with the slots on the system.
  2. Slide the EDSFF E3.S backplane module towards the rear of the system, until it is firmly secured.
  3. Using a Phillips #2 screwdriver, tighten the captive screw on the EDSFF E3.S backplane module.
    Figure 1. Installing the EDSFF E3.S backplane module
    This image shows Installing the EDSFF E3.S backplane modulw

Next steps

  1. Connect all the cables, observe the cable routing.
    NOTE:See cable routing section; configuration 45 or 46 for more information.
  2. Install the EDSFF E3.S PERC module.
  3. Install the cooling fan cage assembly.
  4. If removed, install the air shroudor install the GPU air shroud.
  5. Install the drive backplane cover.
  6. Install the EDSFF E3.S drives .
  7. Install the front bezel.
  8. Follow the procedure listed in After working inside your system.