Configuring controller properties using RACADM

  • To set Patrol Read Mode:
    racadm set storage.controller.<index>.PatrolReadMode  {Automatic | Manual | Disabled}
  • If Patrol read mode is set to manual, use the following commands to start and stop Patrol read Mode:
    racadm storage patrolread:<Controller FQDD> -state {start|stop}
    NOTE: Patrol read mode operations such as Start and Stop are not supported if there are no virtual disks available in the controller. Though you can invoke the operations successfully using the iDRAC interfaces, the operations will fail when the associated job is started.
  • To specify the Check Consistency Mode, use Storage.Controller.CheckConsistencyMode object.
  • To enable or disable the Copyback Mode, use Storage.Controller.CopybackMode object.

  • To enable or disable the Load Balance Mode, use Storage.Controller.PossibleloadBalancedMode object.

  • To specify the percentage of the system's resources dedicated to perform a check consistency on a redundant virtual disk, use Storage.Controller.CheckConsistencyRate object.

  • To specify the percentage of the controller's resources dedicated to rebuild a failed disk, use Storage.Controller.RebuildRate object

  • To specify the percentage of the controller's resources dedicated to perform the background initialization (BGI) of a virtual disk after it is created, useStorage.Controller.BackgroundInitializationRate object

  • To specify the percentage of the controller's resources dedicated to reconstruct a disk group after adding a physical disk or changing the RAID level of a virtual disk residing on the disk group, use Storage.Controller.ReconstructRate object

  • To enable or disable the enhanced auto import of foreign configuration for the controller, use Storage.Controller.EnhancedAutoImportForeignConfig object

  • To create, modify, or delete security key to encrypt virtual drives:

    racadm storage createsecuritykey:<Controller FQDD> -key <Key id> -passwd <passphrase>
    racadm storage modifysecuritykey:<Controller FQDD> -key <key id> -oldpasswd <old passphrase> -newpasswd <new passphrase>
    racadm storage deletesecuritykey:<Controller FQDD>