TMP0100

Message
The system board arg1 temperature is less than the lower warning threshold.
Arguments
arg1 = name
Detailed Description
Ambient air temperature is too cool.
Recommended Response Action
Check system operating environment.
Category
System Health (TMP = Temperature)
Severity
Severity 2 (Warning)
Trap/EventID
2162
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

TMP0101

Message
The system board arg1 temperature is less than the lower critical threshold.
Arguments
arg1 = name
Detailed Description
Ambient air temperature is too cool.
Recommended Response Action
Check system operating environment.
Category
System Health (TMP = Temperature)
Severity
Severity 1 (Critical)
Trap/EventID
2161
LCD Message
System board temperature is outside of range. Check Fans
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

TMP0102

Message
The system board arg1 temperature is greater than the upper warning threshold.
Arguments
arg1 = name
Detailed Description
Ambient air temperature is too warm or one or more fans may have failed.
Recommended Response Action
Check system operating environment and review event log for fan failures.
Category
System Health (TMP = Temperature)
Severity
Severity 2 (Warning)
Trap/EventID
2162
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

TMP0103

Message
The system board arg1 temperature is greater than the upper critical threshold.
Arguments
arg1 = name
Detailed Description
Ambient air temperature is too warm or one or more fans may have failed.
Recommended Response Action
Check system operating environment and review event log for fan failures.
Category
System Health (TMP = Temperature)
Severity
Severity 1 (Critical)
Trap/EventID
2161
LCD Message
System board temperature is outside of range. Check Fans
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

TMP0104

Message
The system board arg1 temperature is outside of range.
Arguments
arg1 = name
Detailed Description
Ambient air temperature is too warm or cool.
Recommended Response Action
Check system operating environment and review event log for fan failures.
Category
System Health (TMP = Temperature)
Severity
Severity 1 (Critical)
Trap/EventID
2161
LCD Message
System board <name> temperature is outside of range Check Fans
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

TMP0105

Message
The system board arg1 temperature is within range.
Arguments
arg1 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (TMP = Temperature)
Severity
Severity 3 (Informational)
Trap/EventID
2163
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

TMP0106

Message
The memory module arg1 temperature is less than the lower warning threshold.
Arguments
arg1 = number
Detailed Description
Ambient air temperature is too cool.
Recommended Response Action
Check system operating environment.
Category
System Health (TMP = Temperature)
Severity
Severity 2 (Warning)
Trap/EventID
2162
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

TMP0107

Message
The memory module arg1 temperature is less than the lower critical threshold.
Arguments
arg1 = number
Detailed Description
Ambient air temperature is too cool.
Recommended Response Action
Check system operating environment.
Category
System Health (TMP = Temperature)
Severity
Severity 1 (Critical)
Trap/EventID
2161
LCD Message
Memory module <number> temperature is outside of range. Check Fans
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

TMP0108

Message
The memory module arg1 temperature is greater than the upper warning threshold.
Arguments
arg1 = number
Detailed Description
Ambient air temperature is too warm or one or more fans may have failed.
Recommended Response Action
Check system operating environment and review event log for fan failures.
Category
System Health (TMP = Temperature)
Severity
Severity 2 (Warning)
Trap/EventID
2162
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

TMP0109

Message
The memory module arg1 temperature is greater than the upper critical threshold.
Arguments
arg1 = number
Detailed Description
Ambient air temperature is too warm or one or more fans may have failed.
Recommended Response Action
Check system operating environment and review event log for fan failures.
Category
System Health (TMP = Temperature)
Severity
Severity 1 (Critical)
Trap/EventID
2161
LCD Message
Memory module <number> temperature is outside of range. Check Fans
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

TMP0110

Message
The memory module arg1 temperature is outside of range.
Arguments
arg1 = number
Detailed Description
Ambient air temperature is too warm or cool.
Recommended Response Action
Check system operating environment and review event log for fan failures.
Category
System Health (TMP = Temperature)
Severity
Severity 1 (Critical)
Trap/EventID
2161
LCD Message
Memory module <number> temperature is outside of range. Check Fans
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

TMP0111

Message
The memory module arg1 temperature is within range.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (TMP = Temperature)
Severity
Severity 3 (Informational)
Trap/EventID
2163
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

TMP0112

Message
The arg1 temperature is less than the lower warning threshold.
Arguments
arg1 = name
Detailed Description
Ambient air temperature is too cool.
Recommended Response Action
Check system operating environment.
Category
System Health (TMP = Temperature)
Severity
Severity 2 (Warning)
Trap/EventID
2162
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

TMP0113

Message
The arg1 temperature is less than the lower critical threshold.
Arguments
arg1 = name
Detailed Description
Ambient air temperature is too cool.
Recommended Response Action
Check system operating environment.
Category
System Health (TMP = Temperature)
Severity
Severity 1 (Critical)
Trap/EventID
2161
LCD Message
The <name> temperature is outside of range. Check Fans
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

TMP0114

Message
The arg1 temperature is greater than the upper warning threshold.
Arguments
arg1 = name
Detailed Description
Ambient air temperature is too warm or one or more fans may have failed.
Recommended Response Action
Check system operating environment and review event log for fan failures.
Category
System Health (TMP = Temperature)
Severity
Severity 2 (Warning)
Trap/EventID
2162
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

TMP0115

Message
The arg1 temperature is greater than the upper critical threshold.
Arguments
arg1 = name
Detailed Description
Ambient air temperature is too warm or one or more fans may have failed.
Recommended Response Action
Check system operating environment and review event log for fan failures.
Category
System Health (TMP = Temperature)
Severity
Severity 1 (Critical)
Trap/EventID
2161
LCD Message
The <name> temperature is outside of range . Check Fans
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

TMP0116

Message
The arg1 temperature is outside of range.
Arguments
arg1 = name
Detailed Description
Ambient air temperature is too warm or cool.
Recommended Response Action
Check system operating environment and review event log for fan failures.
Category
System Health (TMP = Temperature)
Severity
Severity 1 (Critical)
Trap/EventID
2161
LCD Message
The <name> temperature is outside of range. Check Fans
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

TMP0117

Message
The arg1 temperature is within range.
Arguments
arg1 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (TMP = Temperature)
Severity
Severity 3 (Informational)
Trap/EventID
2163
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

TMP0118

Message
The system inlet temperature is less than the lower warning threshold.
Detailed Description
Ambient air temperature is too cool.
Recommended Response Action
Check system operating environment.
Category
System Health (TMP = Temperature)
Severity
Severity 2 (Warning)
Trap/EventID
2162
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

TMP0119

Message
The system inlet temperature is less than the lower critical threshold.
Detailed Description
Ambient air temperature is too cool.
Recommended Response Action
Check system operating environment.
Category
System Health (TMP = Temperature)
Severity
Severity 1 (Critical)
Trap/EventID
2161
LCD Message
Inlet temperature is lower than critical threshold. Check environment
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

TMP0120

Message
The system inlet temperature is greater than the upper warning threshold.
Detailed Description
Ambient air temperature is too warm.
Recommended Response Action
Check system operating environment.
Category
System Health (TMP = Temperature)
Severity
Severity 2 (Warning)
Trap/EventID
2162
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

TMP0121

Message
The system inlet temperature is greater than the upper critical threshold.
Detailed Description
Ambient air temperature is too warm.
Recommended Response Action
Check system operating environment.
Category
System Health (TMP = Temperature)
Severity
Severity 1 (Critical)
Trap/EventID
2161
LCD Message
Inlet temperature is greater than upper critical threshold. Check environment
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

TMP0122

Message
The system inlet temperature is outside of range.
Detailed Description
Ambient air temperature is too warm or cool.
Recommended Response Action
Check system operating environment.
Category
System Health (TMP = Temperature)
Severity
Severity 1 (Critical)
Trap/EventID
2161
LCD Message
Inlet temperature is outside of range . Check environment
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

TMP0123

Message
The system inlet temperature is within range.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (TMP = Temperature)
Severity
Severity 3 (Informational)
Trap/EventID
2163
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

TMP0124

Message
Disk drive bay temperature is less than the lower warning threshold.
Detailed Description
Ambient air temperature is too cool.
Recommended Response Action
Check system operating environment.
Category
System Health (TMP = Temperature)
Severity
Severity 2 (Warning)
Trap/EventID
2162
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

TMP0125

Message
Disk drive bay temperature is less than the lower critical threshold.
Detailed Description
Ambient air temperature is too cool.
Recommended Response Action
Check system operating environment.
Category
System Health (TMP = Temperature)
Severity
Severity 1 (Critical)
Trap/EventID
2161
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

TMP0126

Message
Disk drive bay temperature is greater than the upper warning threshold.
Detailed Description
Ambient air temperature is too warm or one or more fans may have failed.
Recommended Response Action
Check system operating environment and review event log for fan failures.
Category
System Health (TMP = Temperature)
Severity
Severity 2 (Warning)
Trap/EventID
2162
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

TMP0127

Message
Disk drive bay temperature is greater than the upper critical threshold.
Detailed Description
Ambient air temperature is too warm or one or more fans may have failed.
Recommended Response Action
Check system operating environment and review event log for fan failures.
Category
System Health (TMP = Temperature)
Severity
Severity 1 (Critical)
Trap/EventID
2161
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

TMP0128

Message
Disk drive bay temperature is outside of range.
Detailed Description
Ambient air temperature is too warm or cool.
Recommended Response Action
Check system operating environment and review event log for fan failures.
Category
System Health (TMP = Temperature)
Severity
Severity 1 (Critical)
Trap/EventID
2161
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

TMP0129

Message
Disk drive bay temperature is within range.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (TMP = Temperature)
Severity
Severity 3 (Informational)
Trap/EventID
2163
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

TMP0130

Message
The control panel temperature is less than the lower warning threshold.
Detailed Description
Ambient air temperature is too cool.
Recommended Response Action
Check system operating environment.
Category
System Health (TMP = Temperature)
Severity
Severity 2 (Warning)
Trap/EventID
2162
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*            

TMP0131

Message
The control panel temperature is less than the lower critical threshold.
Detailed Description
Ambient air temperature is too cool.
Recommended Response Action
Check system operating environment.
Category
System Health (TMP = Temperature)
Severity
Severity 1 (Critical)
Trap/EventID
2161
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*            

TMP0132

Message
The control panel temperature is greater than the upper warning threshold.
Detailed Description
Ambient air temperature is too warm or one or more fans may have failed.
Recommended Response Action
Check system operating environment and review event log for fan failures.
Category
System Health (TMP = Temperature)
Severity
Severity 2 (Warning)
Trap/EventID
2162
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*            

TMP0133

Message
The control panel temperature is greater than the upper critical threshold.
Detailed Description
Ambient air temperature is too warm or one or more fans may have failed.
Recommended Response Action
Check system operating environment and review event log for fan failures.
Category
System Health (TMP = Temperature)
Severity
Severity 1 (Critical)
Trap/EventID
2161
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*            

TMP0134

Message
The control panel temperature is outside of range.
Detailed Description
Ambient air temperature is too warm or cool.
Recommended Response Action
Check system operating environment and review event log for fan failures.
Category
System Health (TMP = Temperature)
Severity
Severity 1 (Critical)
Trap/EventID
2161
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*            

TMP0135

Message
The control panel temperature is within range.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (TMP = Temperature)
Severity
Severity 3 (Informational)
Trap/EventID
2163
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*            

TMP0136

Message
The system is automatically turned off because of insufficient cooling.
Detailed Description
The system is automatically turned off because of insufficient cooling.
Recommended Response Action
Replace the fans that have stopped functioning, or add the mininum number of fans recommended. For more information, see the system Owners Manual available at the support site.
Category
System Health (TMP = Temperature)
Severity
Severity 1 (Critical)
Trap/EventID
2161
LCD Message
Insufficient system cooling detected. Check fans
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

TMP0137

Message
The system cooling is working normally.
Detailed Description
The system cooling is working normally.
Recommended Response Action
No response action is required.
Category
System Health (TMP = Temperature)
Severity
Severity 3 (Informational)
Trap/EventID
2163
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

TMP0138

Message
The C1 Enhance (C1E) state is disabled in the server. Increased fan speeds can be expected during high CPU workload.
Detailed Description
Disabling the C1E state in servers with processors that have their Thermal Design Power (TDP) value set to equal to or greater than 155 Watt results in increased fan speed during high CPU workloads.
Recommended Response Action
No response action is required.
Category
System Health (TMP = Temperature)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

TMP0200

Message
CPU arg1 temperature is less than the lower warning threshold.
Arguments
arg1 = number
Detailed Description
System performance may be degraded.
Recommended Response Action
Check system operating environment.
Category
System Health (TMP = Temperature)
Severity
Severity 2 (Warning)
Trap/EventID
2162
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

TMP0201

Message
CPU arg1 temperature is less than the lower critical threshold.
Arguments
arg1 = number
Detailed Description
System performance may be degraded.
Recommended Response Action
Check system operating environment.
Category
System Health (TMP = Temperature)
Severity
Severity 1 (Critical)
Trap/EventID
2161
LCD Message
CPU <number> temperature is outside of range. Check fans
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

TMP0202

Message
CPU arg1 temperature is greater than the upper warning threshold.
Arguments
arg1 = number
Detailed Description
System performance may be degraded.
Recommended Response Action
Check system operating environment, fans, and heatsinks.
Category
System Health (TMP = Temperature)
Severity
Severity 2 (Warning)
Trap/EventID
2162
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

TMP0203

Message
CPU arg1 temperature is greater than the upper critical threshold.
Arguments
arg1 = number
Detailed Description
System performance may be degraded.
Recommended Response Action
Check system operating environment, fans, and heatsinks.
Category
System Health (TMP = Temperature)
Severity
Severity 1 (Critical)
Trap/EventID
2161
LCD Message
CPU <number> temperature is outside of range. Check fans
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

TMP0204

Message
CPU arg1 temperature is outside of range.
Arguments
arg1 = number
Detailed Description
System performance may be degraded.
Recommended Response Action
Check system operating environment, fans, and heatsinks.
Category
System Health (TMP = Temperature)
Severity
Severity 1 (Critical)
Trap/EventID
2161
LCD Message
CPU <number> temperature is outside of range. Check fans
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

TMP0205

Message
CPU arg1 temperature is within range.
Arguments
arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (TMP = Temperature)
Severity
Severity 3 (Informational)
Trap/EventID
2163
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

TMP0300

Message
The Enhanced Cooling Mode feature is enabled.
Detailed Description
The Enhanced Colling Mode feature is enabled.
Recommended Response Action
No response action is required.
Category
System Health (TMP = Temperature)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

TMP0301

Message
The Enhanced Cooling Mode feature is disabled.
Detailed Description
The Enhanced Colling Mode feature is disabled.
Recommended Response Action
No response action is required.
Category
System Health (TMP = Temperature)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

TMP0302

Message
Unable to set Enhanced Cooling Mode because the required power or fan configuration is not available.
Detailed Description
The Enhanced Colling Mode feature cannot be enabled because the necessary power or fan configuration is not available.
Recommended Response Action
Do the following: 1) Check the available power and the fan configuration. 2) If the required power for Enahnced Cooling mode is not available, remove other chassis components which are not being used in order to obtain sufficient power. 3) If the fan configuration does not support Enhanced Cooling Mode, replace unsupported fans with supported ones. 4) If the issue persists, contact your service provider.
Category
System Health (TMP = Temperature)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

TMP1000

Message
arg1 exceeded the maximum warning threshold.
Arguments
arg1 = tempsensor name
Detailed Description
The enclosure is too hot. A variety of factors can cause the excessive temperature. For example, a fan may have failed, the thermostat may be set too high, or the room temperature may be too hot.
Recommended Response Action
Check for factors that may cause overheating. For example, verify that the enclosure fan is working. You should check the thermostat settings and examine whether the enclosure is located near a heat source. Make sure the enclosure has enough ventilation and that the room temperature is not too hot. Refer to the enclosure documentation for more diagnostic information.
Category
Storage (TMP = Temperature)
Severity
Severity 2 (Warning)
Trap/EventID
4210
OMSA Event ID
2100
OMSA Trap ID
105300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

TMP1001

Message
arg1 has crossed the minimum warning threshold.
Arguments
arg1 = tempsensor name
Detailed Description
The enclosure is too cold.
Recommended Response Action
Check whether the thermostat setting is too low and whether the room temperature is too cool.
Category
Storage (TMP = Temperature)
Severity
Severity 2 (Warning)
Trap/EventID
4210
OMSA Event ID
2101
OMSA Trap ID
105300
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

TMP1002

Message
arg1 has exceeded the maximum failure threshold.
Arguments
arg1 = tempsensor name
Detailed Description
The enclosure is too hot. A variety of factors can cause the excessive temperature. For example, a fan may have failed, the thermostat may be set too high, or the room temperature may be too hot.
Recommended Response Action
Check for factors that may cause overheating. For example, verify that the enclosure fan is working. You should also check the thermostat settings and examine whether the enclosure is located near a heat source. Make sure the enclosure has enough ventilation and that the room temperature is not too hot. Refer to the enclosure documentation for more diagnostic information.
Category
Storage (TMP = Temperature)
Severity
Severity 1 (Critical)
Trap/EventID
4209
OMSA Event ID
2102
OMSA Trap ID
105400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

TMP1003

Message
arg1 has crossed the minimum failure threshold.
Arguments
arg1 = tempsensor name
Detailed Description
The enclosure is too cold.
Recommended Response Action
Check whether the thermostat setting is too low and whether the room temperature is too cool.
Category
Storage (TMP = Temperature)
Severity
Severity 1 (Critical)
Trap/EventID
4209
OMSA Event ID
2103
OMSA Trap ID
105400
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

TMP1004

Message
The temperature sensor arg1 is now within configured threshold values.
Arguments
arg1 = temperature sensor name
Detailed Description
The enclosure temperature sensor identified in the message is operating within the upper and lower configured temperature thresholds.
Recommended Response Action
No response action is required.
Category
Storage (TMP = Temperature)
Severity
Severity 3 (Informational)
Trap/EventID
4211
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*          

TMP5

Message
The temperature probe maximum warning value was changed on arg1 .
Arguments
arg1 = Enclosure name
Detailed Description
You have changed the value for the maximum temperature probe warning threshold. This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (TMP = Temperature)
Severity
Severity 3 (Informational)
Trap/EventID
4211
OMSA Event ID
2154
OMSA Trap ID
105100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

TMP500

Message
The arg1 sensor has failed with value the arg2 degrees Celsius.
Arguments
arg1 = sensor name, arg2 = temperature
Detailed Description
A temperature sensor identified in the message has failed. This condition can cause system performance issues and degradation in the moitoring capability of the system.
Recommended Response Action
Verify the Embedded System Management (ESM) Log for any sensor related faults. If there is a failed sensor, replace the system board. For more information, contact your service provider.
Category
System Health (TMP = Temperature)
Severity
Severity 1 (Critical)
OMSA Event ID
5050
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC     ✔*        
CMC              

TMP501

Message
Unable to read the arg1 sensor value.
Arguments
arg1 = sensor name
Detailed Description
A temperature sensor identified in the message has failed. This condition can cause system performance issues and degradation in the moitoring capability of the system.
Recommended Response Action
Verify the Embedded System Management (ESM) Log for any sensor related faults. If there is a failed sensor, replace the system board. For more information, contact your service provider.
Category
System Health (TMP = Temperature)
Severity
Severity 2 (Warning)
OMSA Event ID
5051
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC     ✔*        
CMC              

TMP502

Message
The arg1 sensor has returned to a normal state with a value of arg2 degrees Celsius.
Arguments
arg1 = sensor name, arg2 = temperature
Detailed Description
The sensor identified in the message has returned to a normal state.
Recommended Response Action
No response action is required.
Category
System Health (TMP = Temperature)
Severity
Severity 3 (Informational)
OMSA Event ID
5052
OMSA Trap ID
5052
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC     ✔*    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC     ✔*        
CMC              

TMP503

Message
The arg1 sensor state has changed to a warning state with a value of arg2 degrees Celsius.
Arguments
arg1 = sensor name, arg2 = temperature
Detailed Description
The temperature sensor identified in the message is faulty, or the temperature exceeds the warning threshold. This condition can cause system performance issues and degradation in the moitoring capability of the system.
Recommended Response Action
Verify the Embedded System Management (ESM) Log for any sensor related faults. If there is a failed sensor, replace the system board. For more information, contact your service provider. Otherwise, change the warning threshold for the temperature sensor (if applicable) such that it corresponds to the hardware configuration.
Category
System Health (TMP = Temperature)
Severity
Severity 2 (Warning)
OMSA Event ID
5053
OMSA Trap ID
5053
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC     ✔*    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC     ✔*        
CMC              

TMP504

Message
The arg1 sensor has detected an error with a value of arg2 degrees Celsius.
Arguments
arg1 = sensor name, arg2 = temperature
Detailed Description
The temperature sensor identified in the message is faulty, or the temperature exceeds the critical threshold. This condition can cause system performance issues and degradation in the moitoring capability of the system.
Recommended Response Action
Review system power policy, check system logs for temperature related failures.
Category
System Health (TMP = Temperature)
Severity
Severity 1 (Critical)
OMSA Event ID
5054
OMSA Trap ID
5054
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC     ✔*    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC     ✔*        
CMC              

TMP505

Message
The arg1 sensor has failed with a value of arg2 degrees Celsius.
Arguments
arg1 = sensor name, arg2 = temperature
Detailed Description
The temperature sensor identified in the message has failed.
Recommended Response Action
Verify the Embedded System Management (ESM) Log for any sensor related faults. If there is a failed sensor, replace the system board. For more information, contact your service provider.
Category
System Health (TMP = Temperature)
Severity
Severity 1 (Critical)
OMSA Event ID
5055
OMSA Trap ID
5055
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC     ✔*    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC     ✔*        
CMC              

TMP6

Message
The temperature probe minimum warning value was changed on arg1 .
Arguments
arg1 = Enclosure name
Detailed Description
You have changed the value for the minimum temperature probe warning threshold. This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (TMP = Temperature)
Severity
Severity 3 (Informational)
Trap/EventID
4211
OMSA Event ID
2155
OMSA Trap ID
105100
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*          

TMP7

Message
arg1 has failed.
Arguments
arg1 = Temp Sensor Name
Detailed Description
A device has been failed and the system is no longer functioning in optimal condition.
Recommended Response Action
Replace the device.
Category
Storage (TMP = Temperature)
Severity
Severity 1 (Critical)
Trap/EventID
4209
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC      
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*        

TMP8500

Message
I/O Module arg1 temperature exceeded operating range.
Arguments
arg1 = iom slot name
Detailed Description
The temperature of the I/O Module identified in the message has increased beyond the operational range. Thermal protection shut down the I/O Module. Factors external to the I/O Module may have caused this situation.
Recommended Response Action
Check the chassis event log for fan issues and fix any issues present. If no fan issues are detected, check chassis ambient temperature and make sure the temperature is within operating range. Utilize the RACADM command "racadm getsensorinfo" to check the chassis ambient temperature.
Category
Audit (TMP = Temperature)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

TMP8501

Message
Unable to read planar board temperature sensors. The cooling has been increased to safeguard the system.
Detailed Description
System was unable to read planar board or control panel temperature sensors. The fan speed was increased to protect system hardware.
Recommended Response Action
Remove AC power from the system and reapply AC power. Check to see if the issue is resolved. If the issue persists, contact your service provider.
Category
Audit (TMP = Temperature)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

TMP8502

Message
Able to read planar board temperature sensors. Cooling set for normal chassis operation.
Detailed Description
The system has recovered from being unable to read planar board or control panel temperature sensors.
Recommended Response Action
No response action required.
Category
Audit (TMP = Temperature)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

본 콘텐츠를 평가해주십시오.

정확함
유용함
이해하기 쉬운
이 문서가 도움이 되셨나요?
0/3000 characters
  평점(별 1~5개)을 매겨주십시오.
  평점(별 1~5개)을 매겨주십시오.
  평점(별 1~5개)을 매겨주십시오.
  문서가 도움이 되었는지 여부를 선택하십시오.
  의견에는 <>()\와 같은 특수 문자를 사용할 수 없습니다.