메인 콘텐츠로 이동
  • 빠르고 간편하게 주문
  • 주문 보기 및 배송 상태 추적
  • 제품 목록을 생성 및 액세스
  • 회사 관리를 사용하여 Dell EMC 사이트, 제품 및 제품 수준 연락처를 관리하십시오.

Event and Error Message Reference Guide for 13th Generation Dell PowerEdge ServersVersion 1.2

PDF

PWR Event Messages

PWR0100

Message
The power button was pressed.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR0101

Message
The power button was released.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR0102

Message
The sleep button was pressed.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR0103

Message
The sleep button was released.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR0104

Message
The reset button was pressed.
Detailed Description
The system will reset.
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR0105

Message
The reset button was released.
Detailed Description
The system will reset.
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR0106

Message
The arg1 is latched.
Arguments
arg1 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR0107

Message
The arg1 is unlatched.
Arguments
arg1 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR0108

Message
The arg1 service was requested.
Arguments
arg1 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR0109

Message
The arg1 service has completed.
Arguments
arg1 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR1000

Message
The system performance restored.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
Trap/EventID
2275
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PWR1001

Message
The system performance degraded.
Detailed Description
To avoid shutdown, system performance has been degraded.
Recommended Response Action
Review system configuration and power consumption.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
Trap/EventID
2274
LCD Message
System performance degraded. Check PSUs and system configuration
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PWR1002

Message
The system performance degraded because of thermal protection.
Detailed Description
To avoid shutdown, system performance has been degraded.
Recommended Response Action
Review system configuration and system logs for thermal or environmental failures and warnings.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
Trap/EventID
2274
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PWR1003

Message
The system performance degraded because cooling capacity has changed.
Detailed Description
To avoid shutdown, system performance has been degraded.
Recommended Response Action
If unintended, review system configuration changes and thermal policy.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
Trap/EventID
2274
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PWR1004

Message
The system performance degraded because power capacity has changed.
Detailed Description
To avoid shutdown, system performance has been degraded.
Recommended Response Action
if unintended, review system configuration changes and power policy.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
Trap/EventID
2274
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PWR1005

Message
The system performance degraded because of user-defined power capacity has changed.
Detailed Description
To avoid exceeding the user defined capacity, system performance has been degraded.
Recommended Response Action
If unintended, review system configuration changes and power policy.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
Trap/EventID
2274
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PWR1006

Message
The system halted because system power exceeds capacity.
Detailed Description
The system may shutdown.
Recommended Response Action
Review system configuration, upgrade power supplies or reduce system power consumption.
Category
System Health (PWR = Power Usage)
Severity
Severity 1 (Critical)
Trap/EventID
2273
LCD Message
System power exceeds capacity. System halted. Contact support
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PWR1007

Message
The system performance degraded because power exceeds capacity.
Detailed Description
To avoid shutdown, system performance has been degraded.
Recommended Response Action
Review system configuration, upgrade power supplies or reduce system power consumption.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
Trap/EventID
2274
LCD Message
System power exceeds capacity. Performance degraded. Check PSU configuration
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PWR1008

Message
The system performance degraded because power draw exceeds the power threshold.
Detailed Description
To avoid shutdown, system performance has been degraded.
Recommended Response Action
Review system configuration, upgrade power supplies or reduce system power consumption.
Category
System Health (PWR = Power Usage)
Severity
Severity 1 (Critical)
Trap/EventID
2273
LCD Message
System power exceeds threshold. Performance degraded. Check PSU configuration
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

PWR1009

Message
System power capacity is restored.
Detailed Description
System power capacity is restored.
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
Trap/EventID
2275
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC          
CMC              

PWR200

Message
Enabling the Max Power Conservation Mode (MPCM) feature will disable the Extended Power Performance (EPP) feature.
Detailed Description
Enabling the Max Power Conservation Mode (MPCM) feature will disable the Extended Power Performance (EPP) feature. MPCM forces servers in to a low-power and limited-performance mode, and then disables the ability to turn on additional servers.
Recommended Response Action
No response action required.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR2000

Message
The system powered up.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2001

Message
The system hard reset.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2002

Message
The system warm reset.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2003

Message
User requested a PXE boot.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2004

Message
System booted automatically into diagnostics.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2005

Message
The OS run-time software initiated a hard reset.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2006

Message
The OS run-time software initiated a warm reset.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2007

Message
System restarted.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR201

Message
Selecting the Server Based Power Management Mode option sets your power cap to a maximum value, server priorities to a default priority, and then disables the Max Power Conservation Mode. Do you want to continue?
Detailed Description
Selecting the Server Based Power Management Mode option sets your power cap to a maximum value, server priorities to a default priority, and then disables the Max Power Conservation Mode.
Recommended Response Action
No response action required.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR202

Message
Enabling the Max Power Conservation Mode (MPCM) feature forces servers in to a low-power and limited-performance mode, and then disables the ability to turn on additional servers.
Detailed Description
Enabling the Max Power Conservation Mode (MPCM) feature forces servers in to a low-power and limited-performance mode, and then disables the ability to turn on additional servers.
Recommended Response Action
No response action required.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR203

Message
Unable to set the System Input Power Cap value to less than or equal to 13300 W (45381 BTU/h), because the Extended Power Performance feature is enabled.
Detailed Description
The System Input Power Cap value cannot be set to less than or equal to 13300 W, because the Extended Power Performance feature is enabled.
Recommended Response Action
Enter a Power cap value greater than 13300 W, and then retry the operation.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR204

Message
Object value is successfully modified. Max Power Conservation Mode will deactivate the Extended Power Performance feature.
Detailed Description
Object value is successfully modified. Max Power Conservation Mode will deactivate the Extended Power Performance feature.
Recommended Response Action
No response action required.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR205

Message
The Server Performance Over Power Redundancy (SPOPR) feature cannot be enabled because the Extended Power Performance is enabled.
Detailed Description
The Server Performance Over Power Redundancy (SPOPR) feature cannot be enabled because the Extended Power Performance is enabled.
Recommended Response Action
Disable Extended Power Performance and retry the operation.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR206

Message
The Server Based Power Management (SBPM) feature cannot be enabled because the Extended Power Performance mode is enabled.
Detailed Description
The Server Based Power Management (SBPM) feature cannot be enabled because the Extended Power Performance mode is enabled.
Recommended Response Action
Disable Extended Power Performance and retry the operation.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR207

Message
The Dynamic Power Supply Engagement (DPSE) feature cannot be enabled because the Extended Power Performance mode is enabled.
Detailed Description
The Dynamic Power Supply Engagement (DPSE) feature cannot be enabled because the Extended Power Performance mode is enabled.
Recommended Response Action
Disable Extended Power Performance and retry the operation.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR209

Message
Unable to change the redundancy policy to either Power Supply Redundancy or No Redundancy because the Extended Power Performance is enabled.
Detailed Description
The redundancy policy cannot be changed to either Power Supply Redundancy or No Redundancy because the Extended Power Performance is enabled.
Recommended Response Action
Disable Extended Power Performance and retry the operation.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR210

Message
The redundancy policy cannot be changed to either Power Supply Redundancy or No Redundancy because the Extended Power Performance is enabled.
Detailed Description
The redundancy policy cannot be changed to either Power Supply Redundancy or No Redundancy because the Extended Power Performance is enabled.
Recommended Response Action
No response action required.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR211

Message
Unable to set the Fresh Air (FA) mode because the Extended Power Performance (EPP) feature is enabled.
Detailed Description
The Fresh Air (FA) mode cannot be set because the Extended Power Performance (EPP) feature is enabled.
Recommended Response Action
No response action required.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR213

Message
Cannot enable the Extended Power Performance (EPP) mode because the Max Power Conservation Mode (MPCM) is enabled.
Detailed Description
Cannot enable the Extended Power Performance (EPP) mode because the Max Power Conservation Mode (MPCM) is enabled.
Recommended Response Action
Disable the Max Power Conservation Mode and retry the operation.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR214

Message
Cannot enable the Extended Power Performance (EPP) mode because Dynamic Power Supply Engagement (DPSE) is enabled.
Detailed Description
Cannot enable the Extended Power Performance (EPP) mode because Dynamic Power Supply Engagement (DPSE) is enabled.
Recommended Response Action
DIsable Dynamic Power Supply Engagement (DPSE) and retry the operation.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR216

Message
Unable to enable Extended Power Performance, because Redundancy Policy is set to Grid Redundancy or No Redundancy.
Detailed Description
Unable to enable Extended Power Performance, because redundancy policy is set to Grid Redundancy or No Redundancy.
Recommended Response Action
Configure Redundancy Policy to Power Supply Redundancy and retry the operation. Using the CMC Web GUI, click Power > Configuration. From the Redundancy Policy drop-down menu, select Power Supply Redundancy.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR218

Message
Cannot enable the Extended Power Performance (EPP) feature because the Fresh Air (FA) mode is enabled.
Detailed Description
Cannot enable the Extended Power Performance (EPP) the feature because the Fresh Air (FA) mode is enabled.
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR219

Message
The Extended Power Performance (EPP) feature cannot be enabled because the PSU in slot arg1 is not a 3000 W PSU.
Arguments
arg1 = slot number
Detailed Description
The Extended Power Performance (EPP) feature cannot be enabled because PSU in the slot identified in the message is not a 3000 W PSU.
Recommended Response Action
In order to use the Extended Power Performance (EPP) feature, replace the PSU identified in the message with a 3000 W PSU.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR220

Message
The Extended Power Performance (EPP) feature cannot be enabled because slot arg1 is empty.
Arguments
arg1 = slot number
Detailed Description
The Extended Power Performance (EPP) feature cannot be enabled because the slot identified in the message is empty.
Recommended Response Action
Insert an appropriate PSU in the slot identified in the message and retry the operation.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR2200

Message
The system is in the ON state.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2201

Message
The system is sleeping with system hardware and processor context maintained.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2202

Message
The system is sleeping with lost processor context.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2203

Message
The system is sleeping with system hardware and processor context lost.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2204

Message
The system is in a non-volatile sleep state.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2205

Message
The system is in a soft-off state.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2207

Message
The system is in a mechanical off state.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2208

Message
The system is in a sleep state.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2209

Message
The system is in an undermined sleep state.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR221

Message
The Extended Power Performance (EPP) feature is already disabled.
Detailed Description
The Extended Power Performance (EPP) feature is already disabled.
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR2210

Message
The system was forced into a soft-off state.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2211

Message
The system is in legacy ON state.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2212

Message
The system is in legacy OFF state.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR222

Message
The Extended Power Performance (EPP) feature is already enabled.
Detailed Description
The Extended Power Performance (EPP) feature is already enabled.
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR223

Message
Cannot perform a 110V AC operation because the Extended Power Performance (EPP) feature is enabled.
Detailed Description
Cannot perform a 110V AC operation because the Extended Power Performance (EPP) feature is enabled.
Recommended Response Action
Disable the Extended Power Performance (EPP) feature and retry the operation.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR2250

Message
Unable to turn on the server because the chassis infrastructure not ready.
Detailed Description
The server did not turn on bacause the chassis infrastructure is not ready. The chassis infrstructure includes: PCIe subsystem, storage components, and the chassis management controller.
Recommended Response Action
Check the status of the chassis infrastructure in the CMC Web or RACADM interface. Wait until the chassis infrastructure components are fully turned on.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2251

Message
Unable to turn on the server because the chassis cover is open.
Detailed Description
The server did not turn on because the chassis cover is open.
Recommended Response Action
Close the chassis cover and retry the operation.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2252

Message
Unable to turn on the server because an NDC or Mezzanine card is incompatible with the I/O Module or PCIe subsystem.
Detailed Description
The server did not turn on because an NDC or Mezzanine card is incompatible with the I/O Module or PCIe subsystem.
Recommended Response Action
Check the release notes for the product and make sure to install compatible componenets in the server.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2253

Message
Unable to turn on the server because a PCIe card or Mezzanine card is not installed.
Detailed Description
The server did not turn on because a PCIe card or Mezzanine card is not installed.
Recommended Response Action
Install a PCI or Mezzanine card in the appropriate slot and retry the operation.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2254

Message
The use of 110V is unacknowledged and the chassis cannot grant power on permission to the server.
Detailed Description
The use of 110V is unacknowledged for the chassis and the chassis cannot grant power on permission to the server.
Recommended Response Action
Check for unacknowledged use of 110V and change to acknowledged. Using the Chassis Management Controller (CMC) web interface, select Chassis Overview>Power>Configuration and then check the 110V Acknowledge field. Retry the operation to turn on the server.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2255

Message
The Chassis Managment Controller (CMC) is configured in Max Power Conservation Mode and is unable to grant power on permission to the server.
Detailed Description
The Chassis Managment Controller (CMC) is configured in Max Power Conservation Mode and is unable to grant power on permission to the server.
Recommended Response Action
Disable the Max Powe Conservation Mode on the chassis and retry the operation. Using the Chassis Management Controller (CMC) web interface, select Chassis Overview>Power>Configuration and then uncheck the Max Power Conservation Mode field.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2256

Message
Unable to allocate power for servers to turn on because the Chassis Management Controller (CMC) is initializing chassis infrastructure components.
Detailed Description
The chassis infrastructure components are being initialized and are not ready to grant power on permission to the servers.
Recommended Response Action
Wait until the chassis infrastructure has been initialized and then retry the operation. To check that the infrastructure is initialized, using the RACADM command line utility run the command "racadm getmodinfo" and check that the "pwrstate" field is on for the chassis component.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2257

Message
The target power allocation override is arg1 . The target power allocation (AC) is arg2 Watts.
Arguments
arg1 = override state, arg2 = target power
Detailed Description
The target power allocation override has been enabled or disabled as identified in the message.
Recommended Response Action
No response action required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2258

Message
The Power Supply Unit (PSU) hotspare thresholds were modified. Wake Threshold: arg1 %, Sleep Threshold: arg2 %.
Arguments
arg1 = wake threshold, arg2 = sleep threshold
Detailed Description
The Power Supply Unit (PSU) hotspare thresholds were modified to the Wake Threshold and Sleep Threshold identified in the message.
Recommended Response Action
No response action required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2260

Message
The Intel Management Engine is unresponsive and the server thermal failsafe state is activated.
Detailed Description
The iDRAC experienced an IPMB communication issue with the Intel Management Engine and was not able to recover IPMB communications. The server thermal failsafe state is activiated.
Recommended Response Action
Disconnect power from the server and reconnect power. Turn on the server. If the issue persists, contact your service provider.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2261

Message
Current Monitor initialization issue observed, IMON Revision arg1 , CPLD IMON MFR Revision arg2 .
Arguments
arg1 = current monitor revision number, arg2 = CPLD revision number
Detailed Description
The iDRAC experienced an issue initializing the Current Monitor. The system motherboard may need replacement.
Recommended Response Action
Contact your service provider.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2262

Message
The Intel Management Engine has reported an internal system error.
Detailed Description
The Intel Management Engine is unable to utilize the PECI over DMI facility.
Recommended Response Action
Look for the PWR2264 "normal system operation" message in the Lifecycle Log after the PWR2262 entry. It may take 30 seconds for the message to be logged. If the PWR2264 message does not appear, do the following: Disconnect power from the server and reconnect power. Turn on the server. If the issue persists, contact your service provider.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2263

Message
User ignored Power Supply Oversubscription Warning.
Detailed Description
User continued after receiving power supplyoversubscription warning (F1/F2).
Recommended Response Action
No response action required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2264

Message
The Intel Management Engine has reported normal system operation.
Detailed Description
The Intel Management Engine ihas recovered the ablility to utilize the PECI over DMI facility.
Recommended Response Action
If the PWR2262 "internal system error" was logged within the previous 30 seconds, ignore the message. No response action required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2400

Message
Power management firmware unable to maintain power limit
Detailed Description
The power management firmware cannot reduce power consumption to meet configuration or user defined settings,
Recommended Response Action
"1) Review system power policy. 2) Check system event logs for thermal or power related exceptions."
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2401

Message
Power management firmware initialization error
Detailed Description
The iDRAC controller detected that the power management firmware did not initialize properly. The system may operate in a performance degraded state.
Recommended Response Action
"1) Disconnect system input power, wait one minute, reconnect system input power. 2) Re-flash system BIOS. 3) Upgrade system BIOS to the latest revision."
Category
System Health (PWR = Power Usage)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2402

Message
iDRAC is unable to communicate with power management firmware.
Detailed Description
The iDRAC controller cannot communicate with the power management firmware due to an problem with the interface to the power management engine or with the power management engine itself. The system may operate in a performance degraded state.
Recommended Response Action
Check the Lifecycle Controller Log (LC Log) and make sure that there are no subsequent log entries indicating that Communication with power management firmware has been restored. If this log entry is not present then do one of the following: 1) Disconnect system input power, wait one minute, reconnect system input power. 2) Re-flash system BIOS. 3) Upgrade system BIOS to the latest revision.
Category
System Health (PWR = Power Usage)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2403

Message
iDRAC communication with power management firmware has been restored.
Detailed Description
The iDRAC controller established communication to the power management firmware. System performance will return to normal.
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR2404

Message
Power supply capacity alert disabled.
Detailed Description
Power supply capacity alert disabled due to user configuration.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

PWR3000

Message
The system is being shut down for thermal protection.
Detailed Description
To avoid system damage because of insuffecient cooling, the system is being shut down.
Recommended Response Action
Review the Embedded System Management Log for thermal or environmental failures and warnings, and replace the faulty components. If the issue persists, contact your service provider.
Category
System Health (PWR = Power Usage)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR3001

Message
Detected new peak power value. Peak value (in Watts): arg1 .
Arguments
arg1 = peak value
Detailed Description
The system has detected a new peak power value.
Recommended Response Action
Make sure that the power usage corresponds to the the current hardware configuration and workload.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
OMSA Event ID
5013
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC     ✔*        
CMC              

PWR8500

Message
Chassis power state updated to arg1 from arg2 .
Arguments
arg1 = new power state, arg2 = old power state
Detailed Description
The chassis power state from the configuration database and the current state are different. The current chassis power state will be updated in the configuration database. This is to insure the chassis power state will be the same if the CMC is rebooted or a CMC failover occurs. Note that the numerical value of the state is intended for technical support use.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8501

Message
Successfully set Virtual Infrastructure Device power to arg1 WDC
Arguments
arg1 = power reading
Detailed Description
Power allocation succeeded for Virtual infrastructure.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8503

Message
The current value of System Input Power Cap ( arg1 AC) is less than the upper limit ( arg2 AC).
Arguments
arg1 = power value, arg2 = power value
Detailed Description
This Information is provided to enable checking whether the powercap is lower than the maximum supported powercap limit.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8504

Message
Chassis power button is pressed, but the button is disabled.
Detailed Description
The chassis power button press is detected but the button has been disabled.
Recommended Response Action
The chassis power button is disabled. To enable the chassis power button use the CMC RACADM command line interface, CMC Web interface. Using the command line, enter "racadm config -g cfgChassisPower -o cfgChassisPowerButtonEnable 1". Using the Web interface, click Chassis Overview > Power > Configuration. Clear the Disable Chassis Power Button check box.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8505

Message
The Dynamic Power Supply Engagement feature was not successfully enabled.
Detailed Description
The Dynamic Power Supply Engagement feature was not successfully enabled.
Recommended Response Action
Restart the Chassis Management Controller and retry the operation. To restart the Chassis Management Controller, using the WEB UI, go to Chassis Overview > Power > Control, select the Reset CMC option, and then click Apply.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8506

Message
Cumulative power computation (KWH) time is reset on arg1 .
Arguments
arg1 = time
Detailed Description
Resetting the power computation reading causes the log to report time at which it is reset.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8507

Message
System Input Power Cap changed from arg1 W AC to arg2 W AC.
Arguments
arg1 = previous power value, arg2 = new power value
Detailed Description
The system Input Power Cap was changed from the value to the value indicated in the message.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8508

Message
New power budget ( arg1 W AC) may permit future degradation of redundancy.
Arguments
arg1 = power value
Detailed Description
If the power budget exceeds the effective capacity for the current redundancy policy, it is possible for power allocations to grow beyond the effective capacity, which would reduce redundancy capabilities.
Recommended Response Action
No response action is required. Make sure there are enough PSUs to support redundancy at the specified power budget.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8509

Message
Unable to change the server power priority because Server Based Power Management mode is enabled.
Detailed Description
Unable to change the server power priority because Server Based Power Management mode is enabled.
Recommended Response Action
The server power priority can be changed once Server Based Power Management mode is disabled. Using the CMC Web UI, navigate to the Chassis Overview > Power > Configuration page, then uncheck the Enable Server Based Power Management checkbox. Retry the operation.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8510

Message
Unable to set chassis power property arg1 .
Arguments
arg1 = property name
Detailed Description
Unable to set the chassis power identified in the message.
Recommended Response Action
Retry the operation. If the issue persists, contact your service provider.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8511

Message
Unable to set the CHASSIS_POWER_button_disable chassis power property.
Detailed Description
Unable to set the CHASSIS_POWER_button_disable chassis power property.
Recommended Response Action
Retry the operation. If the issue persists, contact your service provider.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8512

Message
CMC rebooted, because the power configuration data could not be accessed.
Detailed Description
Power configuration data in memory cannot be accessed due to synchronization issues.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8514

Message
Unable to perform chassis power action due to insufficient privileges.
Detailed Description
The user account credentials provided for this chassis power action do not have the correct privilege. Chassis control privilege is required to perform chassis power actions.
Recommended Response Action
Retry to action with a different user account that has chassis power control privilege.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8515

Message
Unable to perform the chassis power action because the chassis is not turned on.
Detailed Description
Unable to perform the chassis power action because the chassis is not turned on.
Recommended Response Action
Turn the chassis on and retry the operation.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8516

Message
Unable to perform the chassis power action requested..
Detailed Description
Unable to perform the chassis power action requested.
Recommended Response Action
Check the tracelog for more information. If the issue persists, contact your service provider.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8517

Message
Unable to turn off chassis power.
Detailed Description
Chassis power state transition did not complete successfully. This may be due to one of the following: 1) Unable to turn off one or more servers, 2) A firmware update may be in progress.
Recommended Response Action
Check the tracelog for more information. If the issue persists, contact your service provider.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8518

Message
Unable to perform the chassis power action because the chassis is already turned on.
Detailed Description
Unable to perform the chassis power action because the chassis is already turned on.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8519

Message
Unable to perform the chassis power action because the chassis is already turned off.
Detailed Description
Unable to perform the chassis power action because the chassis is already turned off.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8520

Message
Initiated the chassis reset operation.
Detailed Description
The chassis reset operation was initiated.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8521

Message
Completed chassis reset operation.
Detailed Description
The chassis reset operation was completed.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8522

Message
Initiated chassis power cycle operation.
Detailed Description
The chassis power cycle operation was initiated.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8523

Message
Completed chassis power cycle operation.
Detailed Description
The chassis power cycle operation was completed.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8524

Message
Redundancy was lost, while Server Performance Over Power Redundancy is enabled.
Detailed Description
The redundancy was lost because the power requirement of the chassis exceeds the current redundant policy.
Recommended Response Action
No response action is required. Review the power requirements and determine if more PSUs are needed to restore redundancy.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8525

Message
110VAC Operation acknowledged.
Detailed Description
110VAC operation of PSUs is acknowledged.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8526

Message
110VAC Operation unacknowledged.
Detailed Description
110VAC operation of PSUs is unacknowledged.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8527

Message
Server slot power priorities changed - reallocating power.
Detailed Description
Server slot power priorities were changed. Power to servers is being reallocated.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8528

Message
Unable to set Max Power Conservation Mode because the Server Based Power Management mode is enabled.
Detailed Description
The Max Power Conservation Mode can be enabled only when Server Based Power Management Mode is disabled.
Recommended Response Action
The Max Power Conservation Mode can be changed when Server Based Power Management mode is disabled. Using the CMC Web UI, navigate to the Chassis Overview > Power > Configuration page, then uncheck the Enable Server Based Power Management checkbox. Retry the operation.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8529

Message
Max Power Conservation Mode is enabled.
Detailed Description
The Max Power Conservation Mode is enabled.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8530

Message
Max Power Conservation Mode is disabled.
Detailed Description
Max Power Conservation Mode is disabled.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8531

Message
Server Based Power Management Mode is enabled.
Detailed Description
Server Based Power Management Mode is enabled.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8532

Message
Server Based Power Management Mode is disabled.
Detailed Description
Server Based Power Management Mode is disabled.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8533

Message
Power cap changed from arg1 W AC to arg2 W AC.
Arguments
arg1 = power value, arg2 = power value
Detailed Description
Power cap setting was changed.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8534

Message
Unable to set Server Based Power Management Mode to enable.
Detailed Description
Unable to set Server Based Power Management Mode to enable.
Recommended Response Action
Retry the operation. If the issue persists, contact your service provider.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8535

Message
Unable to set Server Based Power Management Mode to disable.
Detailed Description
Unable to set Server Based Power Management Mode to disable.
Recommended Response Action
Retry the operation. If the issue persists, contact your service provider.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8536

Message
Server Performance Over Power Redundancy is enabled.
Detailed Description
Server Performance Over Power Redundancy is enabled.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8537

Message
Server Performance Over Power Redundancy is disabled.
Detailed Description
Server Performance Over Power Redundancy is disabled.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8538

Message
Power Remote Logging is enabled.
Detailed Description
Power Remote Logging is enabled.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8539

Message
Power Remote Logging is disabled.
Detailed Description
Power Remote Logging is disabled.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8540

Message
Power Remote Logging Interval set to arg1
Arguments
arg1 = interval
Detailed Description
The interval for remote logging of power information is set to the value identified in the message
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8541

Message
Chassis powerup operation initiated.
Detailed Description
Chassis powerup operation initiated.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8542

Message
Chassis powerup operation completed.
Detailed Description
Chassis powerup operation completed.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8543

Message
Server arg1 power inventory is not valid. Power inventory reading is Max Power= arg2 AC Watt, Min Power= arg3 AC Watt, Allocated Power= arg4 AC Watt
Arguments
arg1 = slot number, arg2 = max power reading, arg3 = min power reading, arg4 = allocated power reading
Detailed Description
Invalid power inventory reported by the iDRAC of the server identified in the message to the CMC.
Recommended Response Action
Turn on the server identified in the message. If the issue persists, contact your service provider.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8544

Message
Chassis Management Controller turned off the Server arg1 because of insufficient power at inventory.
Arguments
arg1 = slot number
Detailed Description
Insufficient power is available for the server identified in the message to function. The server will be turned off until there is sufficient power available.
Recommended Response Action
Make sure there is enough power supply to distribute power. Using the CMC Web UI, go to Chassis Overview > Power > Power Budget Status. In the Total Input Power Available For Allocation field view the available power. To add more power, insert more PSUs or remove unused components from the chassis.
Category
Audit (PWR = Power Usage)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8545

Message
Chassis Management Controller turned off the server arg1 because of incorrect power data retrieved from iDRAC at inventory.
Arguments
arg1 = slot number
Detailed Description
Incorrect power inventory information reported by the iDRAC for the server identified in the message.
Recommended Response Action
Invalid power inventory information could be due to outdated iDRAC firmware or server BIOS firmware versions. Update the components to their latest versions.
Category
Audit (PWR = Power Usage)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8546

Message
Chassis shutdown already in progress.
Detailed Description
A chassis shutdown was already in progress, when the additional shutdown request was received.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8547

Message
Chassis is already powered off.
Detailed Description
The chassis was already turned off, when the power off request was received.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8548

Message
Chassis shutdown operation initiated.
Detailed Description
Chassis shutdown operation initiated.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8549

Message
Chassis shutdown did not complete successfully.
Detailed Description
The requested chassis shutdown operation did not complete successfully.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8550

Message
Chassis shutdown completed.
Detailed Description
Chassis shutdown completed.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC       ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8551

Message
Successfully set Virtual Infrastructure Device power to arg1 DC Watt.
Arguments
arg1 = power reading
Detailed Description
This will be logged when a Virtual Infrastructure Device power allocation is configured.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8552

Message
Chassis Management Controller is unable to turn on arg1 - arg2 because of insufficient power.
Arguments
arg1 = component name, arg2 = component id
Detailed Description
There is insufficient power for the component identified in the message to turn on.
Recommended Response Action
Make sure there is enough power supply to distribute power. Using the CMC Web UI, go to Chassis Overview > Power > Power Budget Status. In the Total Input Power Available For Allocation field view the available power. To add more power, insert more PSUs or remove unused components from the chassis. Contact your service provider for information on the power required for the component identified in the message.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
Trap/EventID
8418
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

PWR8554

Message
Chassis Management Controller is unable to send power allocation information to arg1 - arg2 at priority arg3 .
Arguments
arg1 = component name, arg2 = component id, arg3 = priority number
Detailed Description
This situation occurs if the iDRAC is found to be turned off after power allocation information is sent by the CMC or if the communications between the CMC and iDRAC is non functional.
Recommended Response Action
Perform a Virtual Reseat of the component identified in the message. Using the CMC Web UI, go to Chassis Overview > Troubleshooting > Reset Components, and then select slot for the component identified in the message and apply the Virtual Reseat.
Category
Audit (PWR = Power Usage)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8555

Message
Chassis Management Controller unable to turn on arg1 - arg2 at priority arg3 because of insufficient power. Minimum power needed is arg4 AC Watt, but only arg5 AC Watt is available.
Arguments
arg1 = component name, arg2 = slot number, arg3 = priority number, arg4 = min power, arg5 = avaialble power
Detailed Description
The request to turn on the component identified in the message was not successful because insuffficient power is available at the identified priority for the component.
Recommended Response Action
Make sure there is enough power supply to distribute power. Using the CMC Web UI, go to Chassis Overview > Power > Power Budget Status. In the Total Input Power Available For Allocation field view the available power. To add more power, insert more PSUs or remove unused components from the chassis.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
Trap/EventID
8418
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

PWR8556

Message
Server arg1 was shutdown due to insufficient power.
Arguments
arg1 = slot number
Detailed Description
The Server identified in the message was shutdown due to insufficient power.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 1 (Critical)
Trap/EventID
8417
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

PWR8557

Message
The System Input Power Cap is too low to be enforced using the current Power Supply configuration.
Detailed Description
The current Power Cap setting cannot be enforced. This may be the result of changing the redundancy mode or by changing the PSUs. The power cap setting must be increased to be usable.
Recommended Response Action
Increase the Power Cap value. To increase the Power Cap do one of the following: 1) Using CMC Web interface: Select "Chassis Overview" -> Power -> Configuration and then adjust System Input Power Cap values. 2) Run the following RACADM command at the command line interface: "config -g cfgChassisPower -o cfgChassisPowerCap <value>". Try setting the power cap above the lower bound displayed on the power configuration page.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
Trap/EventID
2274
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

PWR8558

Message
The System Input Power Cap is being enforced with the current Power Supply configuration.
Detailed Description
A configuration change has occurred such that the current power cap is now supported.
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
Trap/EventID
2275
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

PWR8559

Message
Power cycle initiated for I/O Module arg1 .
Arguments
arg1 = iIOM slot name
Detailed Description
Power cycle initiated for the I/O module in the slot identified in the message.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8560

Message
Unable to turn on I/O Module arg1 due to insufficient chassis power.
Arguments
arg1 = IOM slot name
Detailed Description
Unable to turn on the I/O Module identified in the message due to insufficient chassis power.
Recommended Response Action
Utilize the Chassis Management Controller (CMC) web interface to check available power and I/O Module power requirements. If sufficient power is available, restart the CMC and retry the operation. If sufficient power is not available due to an insufficient number of PSUs, add additional PSU(s) and reinsert the I/O Module.
Category
Audit (PWR = Power Usage)
Severity
Severity 1 (Critical)
Trap/EventID
8417
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

PWR8561

Message
Unable to power on server arg1 because of iDRAC communication issue.
Arguments
arg1 = server number
Detailed Description
The Chassis Management Controller is unable to communicate with the Server iDRAC service processor and the server could not be powered on. This situation may occur when iDRAC is rebooting.
Recommended Response Action
Wait for three minutes and then retry the operation. If the issue persists, remove and reinsert the server and wait for the iDRAC to finish restarting.
Category
Audit (PWR = Power Usage)
Severity
Severity 1 (Critical)
Trap/EventID
8417
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

PWR8562

Message
Unable to power on the server arg1 before power on timer expired.
Arguments
arg1 = server number
Detailed Description
Unable to power on the server before the power on timer has expired. This happens if the server did not show power on status change within 30 seconds after the power on operation was initiated. This issue may also occur when iDRAC is rebooting.
Recommended Response Action
The Server may need more time to power on. Wait for ten seconds and check the power status. If the server was not powered on, retry the operation. If the issue persists, remove and reinsert the server, wait for the iDRAC to complete startup, and retry the operation.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8563

Message
Unable to turn on Server arg1 due to I/O fabric inconsistency.
Arguments
arg1 = server number
Detailed Description
The Server identified in the message did not turn on due to a fabric mismatch between the I/O Module and the Mezzanine card on the Server.
Recommended Response Action
Make sure that the hardware compatibility between the I/O Module (IOM) and the Mezzanine (Mezz) card is correct. Check the M1000e Hardware Manual for correct component compatibility.
Category
Audit (PWR = Power Usage)
Severity
Severity 1 (Critical)
Trap/EventID
8417
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

PWR8564

Message
Unable to turn on the Server arg1 because the power request exceeded the System Input Power Cap.
Arguments
arg1 = slot number
Detailed Description
The server identified in the message was not turned on because the available power is less than the requested power.
Recommended Response Action
Utilize the Chassis Management Controller web interface to check the System Input Max Power Capacity Power and server power requirements. If sufficient power is available, retry the operation. Otherwise, increase the System Input Power Cap value.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
Trap/EventID
8418
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

PWR8565

Message
Unable to turn off the Server arg1 due to iDRAC communication issue.
Arguments
arg1 = server number
Detailed Description
The Chassis Management Controller is unable to communicate with the iDRAC service processor for the Server identified in the message and the Server could not be turned off. This situation may occur when iDRAC is rebooting.
Recommended Response Action
Do the following: 1) Wait for a few minutes for the iDRAC service processor to complete startup. 2) Retry the operation. 3) If the issue persists, reset the iDRAC and wait a few minutes for the iDRAC startup to complete before retrying the operation.
Category
Audit (PWR = Power Usage)
Severity
Severity 1 (Critical)
Trap/EventID
8417
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

PWR8566

Message
Unable to turn off the Server arg1 before the Power Off timer expired.
Arguments
arg1 = server number
Detailed Description
Unable to turn off the Server before the Power Off timer has expired. This happens if the Server did not show "power off" status change within 30 seconds after the operation was initiated. This situation may also occur when iDRAC is rebooting.
Recommended Response Action
The Server may need more time to turn off. Wait for ten seconds and check the power status. If the Server was not turned off, retry the operation. If the issue persists, remove and reinsert the Server, wait for the iDRAC to complete startup, and retry the operation.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8567

Message
Unable to turn off Server arg1 on a power cycle action.
Arguments
arg1 = server number
Detailed Description
Unable to turn off the Server on a power cycle operation. This happens if the Server did not show a "power off" status change within the expected time.
Recommended Response Action
The Server could have taken more time to turn off than expected. If the Server is turned off, turn on to complete the power cycle. If the Server has not completed a power cycle, retry the operation.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8568

Message
Server arg1 did not gracefully shutdown before the timer expired.
Arguments
arg1 = slot number
Detailed Description
The server identified in the message did not gracefully shutdown before the CMC shutdown timer expired. This happens if the server did not show power off status change within 60 seconds after the operation was initiated, or if the OS in the server has not successfully shutdown.
Recommended Response Action
Check if the OS in the server identified in the message has successfully shutdown, if not, manually complete the shutdown or wait for the shutdown to complete normally. If the issue persists, perform a forced power down of the server identified in the message.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8569

Message
Unable to power cycle the server arg1 because the server is off.
Arguments
arg1 = slot number
Detailed Description
The requested power cycle operation cannot be performed when the server is not turned on. The server should be already turned on for the power cycle operation to be successful.
Recommended Response Action
Turn on the server, if necessary, before requesting a power cycle operation.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8570

Message
Unable to communicate to the iDRAC, when trying to power cycle the server arg1 .
Arguments
arg1 = slot number
Detailed Description
The Chassis Management Controller is not able to communicate with the iDRAC on the server identified in the message. Therefore, the server could not be power cycled. This situation may occur when iDRAC is rebooting.
Recommended Response Action
Wait for few minutes, and then retry the operation. If the issue persists, do one of the following: 1) Reset the iDRAC, 2) Perform a Virtual Reseat of the server, 3) Remove and re-insert the server.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8571

Message
Unable to perform the power action requested for the server arg1 because another power action is in progress.
Arguments
arg1 = server idr
Detailed Description
Another power action is in progress. The requested power action cannot be carried out until the power action in progress completes
Recommended Response Action
Wait for the power action in progress to complete and retry the operation. It may take a few minutes for the current power action to complete.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8572

Message
Unable to shutdown the server arg1 because the server is off.
Arguments
arg1 = server id
Detailed Description
The server identified in the message can be shutdown only if the server is turned on.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8573

Message
The Chassis Management Controller is unable to communicate to the iDRAC, when trying to turn off the server arg1 .
Arguments
arg1 = server id
Detailed Description
The Chassis Management Controller is not able to communicate with the iDRAC on the server identified in the message. Therefore the server could not be turned off. This situation may occur when iDRAC is restarting.
Recommended Response Action
Wait for three minutes, and then retry the operation. If the issue persists, remove and reinsert the server and wait for the iDRAC to finish restarting before retying the operation.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
Trap/EventID
8418
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

PWR8574

Message
The Chassis Management Controller is unable to communicate to the iDRAC, when trying to hard reset the server arg1 .
Arguments
arg1 = slot number
Detailed Description
The Chassis Management Controller is not able to communicate with the iDRAC on the server identified in the message. Therefore the server could not be hard reset. This situation may occur when iDRAC is restarting.
Recommended Response Action
Wait for three minutes, and then retry the operation. If the issue persists, remove and reinsert the server and wait for the iDRAC to finish restarting before retying the operation.
Category
Audit (PWR = Power Usage)
Severity
Severity 1 (Critical)
Trap/EventID
8417
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

PWR8575

Message
Initiated the Virtual Reseat of server arg1 .
Arguments
arg1 = server id
Detailed Description
A Virtual Reseat for the server identified in the message is initiated. A Virtual Reseat is the same as removing and inserting a server.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8576

Message
Unable to turn on the Sleeve or Sled arg1 after a virtual reseat operation.
Arguments
arg1 = slot number
Detailed Description
The virtual reseat initiated on the Sleeve or Sled identified in the message successfully turned off the component. However, the Sleeve or Sled did not turn on successfully. A virtual reseat is the same as removing and inserting a Sleeve or Sled.
Recommended Response Action
Retry the virtual reseat operation on the Sleeve or Sled identified in the message. If the issue persists, manually remove and reinsert the Sleeve or Sled in the chassis.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8577

Message
A virtual reseat operation is initiated on Sleeve or Sled arg1 .
Arguments
arg1 = slot number
Detailed Description
A virtual reseat operation is initiated on the Sleeve or Sled identified in the message. A virtual reseat is the same as removing and inserting a Sleeve or Sled.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8578

Message
Chassis Management Controller is unable to turn on the iDRAC on server- arg1 because power required is less than available power.
Arguments
arg1 = slot number
Detailed Description
The Chassis Management Controller is unable to turn on the iDRAC because power required is less than available power.
Recommended Response Action
Make sure there is enough power supply to distribute power. Go to, the Chassis Overview > Power > Power Budget Status. In the Total Input Power Available For Allocation field, view the available power. To add more power, insert more PSUs or remove unused components from the chassis. Remove and reinsert the server when enough power is available.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
Trap/EventID
8418
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

PWR8579

Message
Request to reset the CMC arg1 is initiated.
Arguments
arg1 = slot id
Detailed Description
A request to reset the CMC identified in the message is initiated. If a second CMC is present, a failover to the other CMC will occur as a result.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8580

Message
Chassis Management Controller is unable to turn on server- arg1 because the Chassis is not turned on.
Arguments
arg1 = slot number
Detailed Description
The power on request for the server identified in the message was not successful because the Chassis is turned off.
Recommended Response Action
Turn on the Chassis, and then retry the operation. To turn on the Chassis using the Chassis Management Controller Web UI, go to Chassis Overview > Power > Control, select the Power On System option, and then click Apply.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC       ✔*    
CMC         ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8581

Message
Chassis Management Controller is unable to turn on server- arg1 because another chassis power operation is in progress.
Arguments
arg1 = slot number
Detailed Description
A chassis power operation is currently in progress and the server identified in the message could not be turned on.
Recommended Response Action
Wait until the current chassis power operation is complete and the chassis is On and then retry the operation.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8582

Message
Chassis Management Controller is unable to turn on server- arg1 because Max Power Conservation Mode is enabled.
Arguments
arg1 = slot number
Detailed Description
Unable to turn on the server identified in the message because the Max Power Conservation Mode (MPCM) is enabled. After MPCM is enabled, the chassis will be in power conservation mode and the CMC cannot process any further server power on operation requests.
Recommended Response Action
Disable the Max Power Conservation Mode and retry the operation.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR8583

Message
Chassis Management Controller is unable to turn on server- arg1 because unacknowledged 110V PSUs are present.
Arguments
arg1 = slot number
Detailed Description
To enable 110V operation, the Allow 110VAC Operation feature must be enabled. If the feature is not enabled, the server turn-on operation will not be processed.
Recommended Response Action
On the Power Configuration page, in the Web UI, select the Allow 110VAC Operation for power supplies and retry the operation. Using the RACADM utility, run the following command, "racadm config -g cfgChassisPower -o cfgChassisAllow110VACOperation 1".
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR8584

Message
Chassis Management Controller is unable to turn on server- arg1 because the power supply redundancy is lost and Performance Over Power Redundancy feature is disabled and the power required is less than the available power.
Arguments
arg1 = slot number
Detailed Description
If power redundancy is lost and the server Performance Over Power Redundancy feature is disabled, the server turn-on will not be allowed.
Recommended Response Action
To enable the server to be turned-on, on the Power Configuration page in the Web UI, enable the server Performance Over Power Redundancy option . Using the RACADM utility, run the following command "racadm config -g cfgChassisPower -o cfgChassisPerformanceOverRedundancy 1". Then retry the operation.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR8585

Message
Chassis Management Controller granted the power required to turn on server- arg1 .
Arguments
arg1 = slot number
Detailed Description
Chassis Management Controller granted the power required to turn on the server identified in the message.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR8586

Message
Chassis Management Controller is unable to turn on server- arg1 because it is not supported in the VRTX chassis.
Arguments
arg1 = slot number
Detailed Description
The Chassis does not support the server identified in the message.
Recommended Response Action
The server inserted is not supported in the Chassis. Remove the server from the Chassis.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR8587

Message
Chassis Management Controller is unable to turn on server- arg1 because the chassis enclosure is open.
Arguments
arg1 = slot number
Detailed Description
The server cannot be turned on if the chassis enclosure is open.
Recommended Response Action
The chassis enclosure is open. Retry the operation after closing the enclosure.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR8588

Message
Chassis Management Controller is unable to turn on server- arg1 because a chassis infrastructure firmware update is in progress.
Arguments
arg1 = slot number
Detailed Description
The server identified in the message cannot be turned on while a chassis infrastructure firmware update operation is in progress.
Recommended Response Action
The chassis infrastructure firmware update is in progress. Retry the operation after the firmware update is complete.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

PWR8589

Message
The server- arg1 does not have PCIe Mezzanine card in slot B1.
Arguments
arg1 = slot number
Detailed Description
The PCIe Mezzanine card in the slot B1 is absent. Without PCIe Mezzannine cards, the chassis PCIe cards will not be available for servers.
Recommended Response Action
Insert a PCIe Mezzanine card in slot B1.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8590

Message
The server- arg1 does not have PCIe Mezzanine card in slot C1.
Arguments
arg1 = slot number
Detailed Description
The PCIe Mezzanine card in the slot C1 is absent. Without PCIe Mezzannine cards, the chassis PCIe cards will not be available for servers.
Recommended Response Action
Insert a PCIe Mezzanine card in slot C1.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8591

Message
Servers are turned off to allocate power to the newly inserted hard disk drives.
Detailed Description
Before inserting hard disk drives, always make sure the Chassis has enough available power. Otherwise operating servers may be turned off.
Recommended Response Action
Make sure there is enough power supply to distribute power. Go to, the Chassis Overview > Power > Power Budget Status. In the Total Input Power Available For Allocation field, view the available power. To add more power, insert more PSUs or remove unused components from the chassis.
Category
Audit (PWR = Power Usage)
Severity
Severity 1 (Critical)
Trap/EventID
8417
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

PWR8592

Message
Chassis Management Controller is unable to turn on or turn off the chassis because another chassis power operation is in progress.
Detailed Description
The request to turn on or turn off the chassis was issued before the previous power operation was completed.
Recommended Response Action
Retry the operation after the current operation is complete.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

PWR8593

Message
Chassis Management Controller is unable to turn on or turn off the chassis because the chassis infrastructure component firmware update is in progress.
Detailed Description
The chassis power operation cannot be performed when a chassis infrastructure firmware update is in progress.
Recommended Response Action
Retry the operation after the chassis infrastructure component firmware update is complete.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
No alerts are applicable for this message

PWR8594

Message
Chassis Management Controller is unable to set the Enhanced Cooling Mode because the requested power arg1 AC Watt is more than available power arg2 AC Watt.
Arguments
arg1 = requested watts, arg2 = available watts
Detailed Description
The available power is not sufficient to enable the Enhanced Cooling Mode feature.
Recommended Response Action
Make sure there is enough power supply to enable the Enhanced Cooling Mode feature. Go to, the Chassis Overview > Power > Power Budget Status. In the Total Input Power Available For Allocation field view the available power. To add more power, insert more PSUs or remove unused components from the chassis.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

PWR8595

Message
Chassis Management Controller is unable to turn on server arg1 due to insufficient power for the arg2 .
Arguments
arg1 = slot id, arg2 = chassis component name
Detailed Description
The turn-on request for the server identified in the message did not succeed because of insufficient power to the chassis component identified in the message.
Recommended Response Action
The Chassis Management Controller (CMC) will retry turning on the server and the corresponding components associated to the server after a predefined interval. If the issue persists, refer to the Managing and Monitoring Power section in the CMC User Guide for more information on configuring power management settings.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8596

Message
Chassis Management Controller is unable to turn on server- arg1 because PSU redundancy is lost and the available power is insufficient.
Arguments
arg1 = slot number
Detailed Description
The Chassis Management Controller cannot turn on the server identified in the message, because PSU redundancy is lost or PSUs are removed. Sufficient power is not available for the operation.
Recommended Response Action
Make sure there is enough power supply to distribute power. Go to, the Chassis Overview > Power > Power Budget Status. In the Total Input Power Available For Allocation field, view the available power. To add more power, insert more PSUs or remove unused components from the chassis. When enough power is available, retry the operation.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
No alerts are applicable for this message

PWR8597

Message
The Power Supply Unit (PSU) arg1 is turned off because it is not supported by the Chassis.
Arguments
arg1 = PSU number
Detailed Description
The identified Power Supply Unit (PSU) is turned off because it is not supported by the Chassis.
Recommended Response Action
Replace the PSU identified in the message with an appropriate unit, and then retry the operation. For a list of PSUs that are compatible, consult the system Owners Manual or contact your service provider.
Category
Audit (PWR = Power Usage)
Severity
Severity 1 (Critical)
Trap/EventID
8417
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔* ✔*         ✔*

PWR8598

Message
The Power Supply Unit (PSU) arg1 is turned off because it is not compatible with the other PSUs used in the Chassis.
Arguments
arg1 = PSU number
Detailed Description
The Power Supply Unit (PSU) identified in the message is turned off because it is not compatible with the other PSUs in the Chassis.
Recommended Response Action
Replace the PSU with an appropriate unit, and then retry the operation. For a list of PSUs that are compatible, consult the system Owners Manual or contact your service provider.
Category
Audit (PWR = Power Usage)
Severity
Severity 1 (Critical)
Trap/EventID
8417
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔* ✔*         ✔*

PWR8601

Message
The multinode sled power button is disabled.
Detailed Description
The power buttons for all multinode sleds in the chassis are disabled. The operation to disable the power button is only applicable to the multinode sleds available, and does not affect other servers in the chassis.
Recommended Response Action
To enable the chassis power button use the CMC RACADM command line interface (CLI) or CMC Web interface. At the CLI, enter "racadm config -g cfgChassisPower -o cfgChassisSledPowerButtonEnable 1". Using the Web interface, click Server Overview > Power > Control. Clear the Disable power button for all multinode sleds in the chassis" check box.
Category
Configuration (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8602

Message
The multinode sled power button is enabled.
Detailed Description
The power buttons for all multinode sleds in the chassis are enabled. The operation to enable the power button is only applicable to the multinode sleds available, and does not affect other servers in the chassis.
Recommended Response Action
To disable the chassis power button use the CMC RACADM command line interface (CLI) or CMC Web interface. At the CLI, enter "racadm config -g cfgChassisPower -o cfgChassisSledPowerButtonEnable 0". Using the Web interface, click Server Overview > Power > Control. Select the "Disable power button for all multinode sleds in the chassis" check box.
Category
Configuration (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8654

Message
Chassis Management Controller (CMC) is unable to send power allocation information to the component arg1 - arg2 .
Arguments
arg1 = component name, arg2 = component id
Detailed Description
CMC could not successfully send the power allocation information to the component identified in the message, because either iDRAC is stopped after the power allocation was sent by CMC or the communication between CMC and iDRAC has ended.
Recommended Response Action
Perform a Virtual Reseat operation of the component, and then retry the operation. To virtually reseat a component, log in to the CMC Web interface, select Chassis Overview > Troubleshooting > Reset Components > select the option corresponding to the component, and then click Virtual Reseat.
Category
Audit (PWR = Power Usage)
Severity
Severity 1 (Critical)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8655

Message
Chassis Management Controller (CMC) is unable to turn on the component arg1 - arg2 because of insufficient power. The minimum required power is arg3 AC Watts, but only arg4 AC Watts is available.
Arguments
arg1 = component name, arg2 = slot number, arg3 = min power, arg4 = available power
Detailed Description
CMC could not successfully turn on the component identified in the message, because of insufficient power available.
Recommended Response Action
Make sure there is sufficient power available, and then retry the operation. To view the available power, on the CMC Web interface, click Chassis Overview > Power > Power Budget Status. The available power is displayed in the Total Input Power Available For Allocation field. To increase available power, add more PSUs or remove unused components from the Chassis.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
Trap/EventID
8418
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

PWR8656

Message
Chassis Management Controller (CMC) is unable to turn on the component arg1 - arg2 because of insufficient power.
Arguments
arg1 = component name, arg2 = slot number
Detailed Description
CMC could not successfully turn on the component identified in the message, because of insufficient power available.
Recommended Response Action
Make sure there is sufficient power available, and then retry the operation. To increase available power, add more PSUs, use PSUs with higher voltage inputs or a higher power rating, remove unused components from the Chassis, or change the redundancy policy to Redundancy Alerting Only or Non-redundant.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
Trap/EventID
8418
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

PWR8663

Message
Unable to turn on the server arg1 because of an inconsistency between the I/O module and mezzanine card.
Arguments
arg1 = server number
Detailed Description
The server identified in the message could not be successfully turned on because of incompatibility between the I/O module and mezzanine card.
Recommended Response Action
Make sure that the I/O module and mezzanine card are compatible. For information about compatibility of hardware components, see the Modular System Chassis Hardware Manual.
Category
Audit (PWR = Power Usage)
Severity
Severity 1 (Critical)
Trap/EventID
8417
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

PWR8664

Message
The Dynamic Power Supply Engagement feature is arg1 .
Arguments
arg1 = enabled or disabled
Detailed Description
The power configuration property dynamic power supply engagement feature is disabled or enabled as identified in the message.
Recommended Response Action
No response action is required.
Category
Configuration (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8665

Message
The Chassis power button is arg1 .
Arguments
arg1 = enabled or disabled
Detailed Description
The property chassis power button is either enabled or disabled as identified in the message.
Recommended Response Action
No response action is required.
Category
Configuration (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8666

Message
The iKVM power cycle operation is initiated.
Detailed Description
The iKVM power cycle operation is initiated.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8667

Message
Chassis Management Controller (CMC) is resetting iKVM to its default settings.
Detailed Description
Chassis Management Controller (CMC) is resetting iKVM to its default settings.
Recommended Response Action
No response action is required
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8668

Message
Chassis Management Controller (CMC) has initiated the process of resetting iKVM.
Detailed Description
Chassis Management Controller (CMC) has initiated the process of resetting iKVM.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8669

Message
Unable to turn on the server arg1 because of an inconsistency between the chassis and server components.
Arguments
arg1 = server number
Detailed Description
The server identified in the message could not be successfully turned on because of incompatibility between the chassis PCIe components and mezzanine card.
Recommended Response Action
Make sure that the chassis PCIe components and mezzanine card are compatible. For information about compatibility of hardware components, see the Modular System Chassis Hardware Manual available at the support site.
Category
Audit (PWR = Power Usage)
Severity
Severity 1 (Critical)
Trap/EventID
8417
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

PWR8670

Message
Unable to turn on server arg1 because the required power arg2 AC Watts exceeds the subsystem Connector Limit arg3 AC Watts for IO modules, Blowers and Servers.
Arguments
arg1 = slot ID, arg2 = power level, arg3 = power limit
Detailed Description
The server identified in the message cannot be turned on if the Connector Limit for the subsystems identified in the message is exceeded .
Recommended Response Action
Make sure the system operates within the subsystem Connector Limit for the components specified. To review power budget information select Chassis Overview -> Power -> Budget Status. Turn off unused components within the subsystem to make power available for the server to turn on or turn off low priority servers and try the operation again.
Category
Audit (PWR = Power Usage)
Severity
Severity 2 (Warning)
Trap/EventID
8418
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

PWR8671

Message
The Chassis Management Controller is unable to set the Enhanced Cooling Mode because the requested power arg1 AC Watts exceeds the subsystem power limit arg2 AC Watts for IO Modules, Blowers and Servers.
Arguments
arg1 = requested power level, arg2 = power limit
Detailed Description
The Enhanced Cooling Mode feature cannot be enabled because the requested power exceeds the Chassis subsystem power limit for IO Modules, Blowers and Servers.
Recommended Response Action
Make sure the system operates within the subsystem Connector Limit for the components specified. To review power budget information select Chassis Overview -> Power -> Budget Status. Turn off unused components within the subsystem to make power available to set Enhanced Cooling Mode.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
Trap/EventID
8419
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*           ✔*

PWR8672

Message
The server in slot arg1 does not have a arg2 mezzanine card in slot arg3 .
Arguments
arg1 = server slot number, arg2 = card type, arg3 = mezzanine position number
Detailed Description
The server identified in the message does not have a card in the Mezzanine slot as identified in the message. A mezzanine card position is identified with the following numbers: For quarter-width server, the position number is 1. For half-width server mezzanine C & B maps to position numbers 1 & 2 respectively. For full-width server, mezzanine C & B on the upper- or left part of the server maps to position numbers 1 & 2 respectively. Mezzanine C & B on the lower- or right part of the server maps to position numbers 3 & 4 respectively.
Recommended Response Action
Insert a mezzanine card in the slot identified in the message.
Category
Configuration (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8673

Message
arg1 hassis configuration detected at arg2 arg3 .
Arguments
arg1 = Carrier grade, arg2 = voltage, arg3 = power state
Detailed Description
Displays voltage change with power configuration change.
Recommended Response Action
No response action is required.
Category
Configuration (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC            
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8674

Message
Unable to change the value of Allow 110 VAC Operation property because it is not supported in NEBS configuration PWR or PSU.
Detailed Description
Unable to change the value of the Allow 110 VAC Operation property because it is not supported in NEBS configuration PWR or PSU.
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC            
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8675

Message
AC power supply is detected in the NEBS configuration.
Detailed Description
AC power supply is detected in the NEBS configuration.
Recommended Response Action
No response action is required.
Category
Configuration (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC            
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8676

Message
Unable to set the chassis power property arg1 .
Arguments
arg1 = property name
Detailed Description
The chassis power property identified in the message cannot be set.
Recommended Response Action
Contact your service provider.
Category
Configuration (PWR = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC            
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8677

Message
Dynamic Power Supply Engagement configuration is changed.
Detailed Description
Dynamic Power Supply Engagement configuration is changed.
Recommended Response Action
No response action is required.
Category
Configuration (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC            
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8678

Message
The value of the property arg1 is arg2 .
Arguments
arg1 = power property name, arg2 = enable or disable
Detailed Description
The power property identified in the mesage is changed as identified in the message..
Recommended Response Action
No response action is required.
Category
Configuration (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC            
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8680

Message
The arg1 firmware in the server slot arg2 does not support the storage sled.
Arguments
arg1 = iDRAC/BIOS, arg2 = slot number
Detailed Description
The firmware identified in the message does not support the storage sled.
Recommended Response Action
Update the firmware identified in the message to the supported latest available version. See the latest iDRAC User Guide for information on the versions that support the storage sled.
Category
System Health (PWR = Power Usage)
Severity
Severity 1 (Critical)
Trap/EventID
2273
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔* ✔* ✔*       ✔*

PWR8681

Message
The arg1 firmware in the server slot arg2 does not support additional PCIe slots.
Arguments
arg1 = iDRAC/BIOS, arg2 = slot number
Detailed Description
The firmware identified in the message does not support the PCIe reassignment operation.
Recommended Response Action
Update the firmware identified in the message to the supported latest available version. See the latest iDRAC User Guide for information on the versions that support the PCIe reassignment.
Category
System Health (PWR = Power Usage)
Severity
Severity 1 (Critical)
Trap/EventID
2273
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔*   ✔*       ✔*

PWR8682

Message
Unable to turn on the storage sled controller arg1 in slot arg2 because the arg3 module is not functioning.
Arguments
arg1 = controller number, arg2 = slot number, arg3 = module name
Detailed Description
The Chassis Management Controller (CMC) is unable to turn on the storage sled controller identified in the message. The Chassis storage sled controller is unable to turn on due to a configuration or hardware issue.
Recommended Response Action
Remove the storage sled identified in the message, re-insert it and observe whether the issue is resolved. If the issue persists, contact your service provider.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
Trap/EventID
2274
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔* ✔*  
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔* ✔* ✔*       ✔*

PWR8683

Message
Initiated the Virtual Reseat of peripheral arg1 .
Arguments
arg1 = slot number
Detailed Description
A Virtual Reseat for the peripheral sled identified in the message is initiated. A Virtual Reseat is the same as removing and inserting a peripheral sled.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC              
CMC            
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

PWR8684

Message
Storage sled controller arg1 in slot arg2 turned on successfully.
Arguments
arg1 = controller number, arg2 = slot number
Detailed Description
The storage sled controller in the slot identified in the message turned on successfully.
Recommended Response Action
No response action is required.
Category
System Health (PWR = Power Usage)
Severity
Severity 3 (Informational)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC            
CMC            
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔* ✔*         ✔*

PWR8685

Message
The arg1 firmware in the server slot arg2 supports the storage sled.
Arguments
arg1 = iDRAC/BIOS, arg2 = slot number
Detailed Description
The firmware identified in the message supports the storage sled.
Recommended Response Action
No response action is required.
Category
Audit (PWR = Power Usage)
Severity
Severity 3 (Informational)
Trap/EventID
8419
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC     ✔* ✔* ✔*  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔* ✔*       ✔*

PWR8686

Message
The Chassis Management Controller (CMC) is unable to turn on the storage sleds associated with server in slot arg1 because the iDRAC firmware version in the server does not support the chassis storage module.
Arguments
arg1 = slot number
Detailed Description
The Chassis Management Controller (CMC) is unable to turn on the storage sled controller identified in the message because iDRAC version installed on the server is not compatible.
Recommended Response Action
Update the the iDRAC firmware identified in the message to the supported latest available version and retry the operation. For information about the supported firmware versions, refer to the Chassis Management Controller users Guide available at the support site.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
Trap/EventID
2274
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔*  
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔* ✔* ✔*       ✔*

PWR8687

Message
The Chassis Management Controller (CMC) is unable to turn on the storage sled controller installed on server in slot arg1 because the server does not have a Mezzanine card.
Arguments
arg1 = server slot
Detailed Description
The Chassis Management Controller (CMC) is unable to turn on the storage sled controller installed on the server in the slot identified in the message because the server does not have a Mezzanine card. A Mezzanine card position is identified with the following numbers: For quarter-width server, the position number is 1. For half-width server mezzanine C & B maps to position numbers 1 & 2 respectively. For full-width server, Mezzanine C & B on the upper- or left part of the server maps to position numbers 1 & 2 respectively. Mezzanine C & B on the lower- or right part of the server maps to position numbers 3 & 4 respectively.
Recommended Response Action
Install a Mezzanine card in the Mezzanine card slot of the server identified in the message, and then retry the operation.
Category
System Health (PWR = Power Usage)
Severity
Severity 2 (Warning)
Trap/EventID
2274
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC   ✔* ✔* ✔*  
CMC   ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*   ✔*        
CMC ✔* ✔* ✔*       ✔*

본 콘텐츠를 평가해주십시오.

정확함
유용함
이해하기 쉬운
이 문서가 도움이 되셨나요?
0/3000 characters
  평점(별 1~5개)을 매겨주십시오.
  평점(별 1~5개)을 매겨주십시오.
  평점(별 1~5개)을 매겨주십시오.
  문서가 도움이 되었는지 여부를 선택하십시오.
  의견에는 <>()\와 같은 특수 문자를 사용할 수 없습니다.