Event and Error Message Reference Guide for 13th Generation Dell PowerEdge ServersVersion 1.2

PDF

POW Event Messages

POW000

Message
Power on permission error, chassis infrastructure not ready.
Detailed Description
Host failed to power up bacause chassis infrastructure is not ready. This messages has been replaced by Message ID PWR2250
Recommended Response Action
Check status of chassis infrastructure.
Category
Audit (POW = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC      
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

POW001

Message
Power on permission error, chassis cover open.
Detailed Description
Host failed to power up because chassis cover is open.This messages has been replaced by Message ID PWR2251
Recommended Response Action
Check chassis cover.
Category
Audit (POW = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC      
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

POW002

Message
Power on permission error, unknown component installed in Fabric1/Fabric2.
Detailed Description
Host failed to power up because unsupported components installed in Fabric1/fabric2.This messages has been replaced by Message ID PWR2252
Recommended Response Action
Check for unsupported components installed in Fabric1/Fabric2.
Category
Audit (POW = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC      
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

POW003

Message
Power on permission error, no PCI/Mezz card installed in Fabric1/Fabric2
Detailed Description
Host failed to power up because PCI/Mezz cards not installed in Fabric1/Fabric2.This messages has been replaced by Message ID PWR2253
Recommended Response Action
Install PCI/Mezz card in Fabric1/Fabric2.
Category
Audit (POW = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

POW004

Message
Power on permission error, unacknowledge use of 110V.
Detailed Description
Host failed to power up because of unacknowledged use of 110V. This messages has been replaced by Message ID PWR2254
Recommended Response Action
Check for unacknowledged use of 110V.
Category
Audit (POW = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

POW005

Message
Power on permission error, CMC is in MPCM mode.
Detailed Description
Host failed to power up bacause CMC MPCM mode is enabled. This messages has been replaced by Message ID PWR2255
Recommended Response Action
Disable MPCM mode to power up.
Category
Audit (POW = Power Usage)
Severity
Severity 2 (Warning)
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC          
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              