Event and Error Message Reference Guide for 13th Generation Dell PowerEdge ServersVersion 1.2

PDF

FSD Event Messages

FSD000

Message
Debug authorized by customer; debugcaps: arg1 , was authorized by: arg2 , at arg3 for the period: arg4 to arg5 .
Arguments
arg1 = DebugCaps, arg2 = iDRAC User, arg3 = unblock time, arg4 = start time, arg5 = end time
Detailed Description
The customer has authorized the specified debug capabilities on this iDRAC. (This should occur in response to a request from Dell tech support.) Each debug capability represents a certain action Dell engineers can perform to debug iDRAC.
Recommended Response Action
No response action is required.
Category
Audit (FSD = Debug)
Severity
Severity 3 (Informational)
Trap/EventID
8595
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

FSD001

Message
Debug authorized by Dell; debugcaps: arg1 , at arg2 , was authorized by Dell employee: arg3 , for the time period arg4 to arg5
Arguments
arg1 = DebugCaps, arg2 = grant time, arg3 = Dell employee, arg4 = start time, arg5 = end time
Detailed Description
Dell has authorized the specified debug capabilities. Each debug capability represents a certain action Dell engineers can perform to debug iDRAC.
Recommended Response Action
No response action is required.
Category
Audit (FSD = Debug)
Severity
Severity 3 (Informational)
Trap/EventID
8595
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

FSD002

Message
Debug authorization failed; for debugCaps: arg1 , authorized by iDRAC user: arg2 , and Dell employee: arg3 , at arg4 for the period: arg5 to arg6 .
Arguments
arg1 = DebugCaps, arg2 = IDRAC user, arg3 = Dell employee, arg4 = unblock time, arg5 = start time, arg6 = end time
Detailed Description
A RACADM Debug command failed. If the RACADM Debug command was executed under the direction of Dell tech support then further assistance from tech support should be requested. Otherwise this command is not intended for customer use.
Recommended Response Action
Verify all of the following 1) ensure that the unblock, grant, and invoke/start/stop/resume commands are all executed against the same iDRAC. 2) ensure dat.ini file has not been changed in any way. 3) ensure that current date falls between the start and end times. Note that Dell can further restrict both the set of debugCaps that is authorized and the start and stop times. If an authorized person did not enter a RACADM debug command then an attacker may have entered the command.
Category
Audit (FSD = Debug)
Severity
Severity 2 (Warning)
Trap/EventID
8594
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing  
iDRAC  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              