Event and Error Message Reference Guide For 13th Generation Dell PowerEdge Servers Version 1.50

VDR Event Messages

VDR1

Message
arg1 failed.
Arguments
  • arg1 = VD Name
Detailed Description
A storage component such as a physical disk or an enclosure has failed. The failed component may have been identified by the controller while performing a task such as a rescan or a check consistency.
Recommended Response Action
Replace the failed component. You can identify which component has failed by locating the component that has a red "X" for its status. Perform a rescan after replacing the failed component.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4353
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*        

VDR10

Message
Formatting the arg1 has started.
Arguments
  • arg1 = VD Name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2059
OMSA Trap ID
120100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*        

VDR100

Message
arg1 is unavailable because of incompatibilities with the current controller.
Arguments
  • arg1 = virtual disk
Detailed Description
The virtual disk identified in message cannot be used because of missing features on the current controller. The features may be missing because they are not available in the firmware version on the controller or the necessary licenses are not installed.
Recommended Response Action
Update the controller firmware and license to match the peer controller.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 2 (Warning)
Trap/EventID
4354
OMSA Event ID
2369
OMSA Trap ID
120300
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*        

VDR101

Message
Virtual Adapter mapping reported for arg1 . Virtual Adapter 1 is now arg2 . Virtual Adapter 2 is now arg3 . Virtual Adapter 3 is now arg4 . Virtual Adapter 4 is now arg5
Arguments
  • arg1 = Virtual Disk Name
  • arg2 = Access Policy 1
  • arg3 = Access Policy 2
  • arg4 = Access Policy 3
  • arg5 = Access Policy 4
Detailed Description
Indicates the Virtual Disk to Virtual Adapter Mapping for audit purposes.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*        

VDR1011

Message
Hot Spare Protection policy deviation with severity set at Informational level occurred for arg1 .
Arguments
  • arg1 = virtual disk names
Detailed Description
The number of hot spares available for the virtual disks identified in the message are not compliant with Hot Spare Protection policy, whose severity is set at Informational level.
Recommended Response Action
Make appropriate assignments of hotspares to meet the policy.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
OMSA Event ID
2383
OMSA Trap ID
120100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC      
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC          
CMC              

VDR102

Message
Hot Spare Protection policy deviation with severity set at Warning level occurred for arg1 .
Arguments
  • arg1 = virtual disk names
Detailed Description
The number of hot spares available for the virtual disks identified in the message are not compliant with Hot Spare Protection policy, whose severity is set at Warning level.
Recommended Response Action
Make appropriate assignments of hotspares to meet the policy.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 2 (Warning)
OMSA Event ID
2384
OMSA Trap ID
120300
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC      
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC          
CMC              

VDR103

Message
Hot Spare Protection policy deviation with severity set at Critical level occurred for arg1 .
Arguments
  • arg1 = virtual disk names
Detailed Description
The number of hot spares available for the virtual disks identified in the message are not compliant with Hot Spare Protection policy, whose severity is set at Critical level.
Recommended Response Action
Make appropriate assignments of hotspares to meet the policy.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 1 (Critical)
OMSA Event ID
2385
OMSA Trap ID
120400
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC      
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC          
CMC              

VDR104

Message
Successfully secured arg1 .
Arguments
  • arg1 = virtual disk name
Detailed Description
The secure virtual disk operation was successful on the security capable virtual disk identified in the message. A security capable virtual disk is created using only Self-Encrypting Drives (SED).
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
OMSA Event ID
2393
OMSA Trap ID
120100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC      
CMC     ✔*      
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*            

VDR105

Message
The arg1 on power save mode drives is available.
Arguments
  • arg1 = virtual disk name
Detailed Description
Virtual Disk creation using power save mode drives successfully completed and the Virtual Disk identified in the message is ready for use.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
OMSA Event ID
2403
OMSA Trap ID
120100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC      
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC          
CMC              

VDR106

Message
arg1 on spun down power save mode drives is not available.
Arguments
  • arg1 = virtual disk name
Detailed Description
This alert is generated after successfully configuring a virtual disk on at least one spundown drive. The virtual disk creation is not yet complete on the remaining spundown drives because the drives are still spinning up.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
OMSA Event ID
2404
OMSA Trap ID
120100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC      
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC          
CMC              

VDR107

Message
Successfully resized Controller Enhanced cache ( arg1 ).
Arguments
  • arg1 = virtual disk name
Detailed Description
The Controller Enhanced cache identified in the message was successfully resized.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
OMSA Event ID
2412
OMSA Trap ID
120100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC      
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC          
CMC              

VDR108

Message
Successfully created Controller Enhanced cache ( arg1 ).
Arguments
  • arg1 = virtual disk name
Detailed Description
The Controller Enhanced cache identified in the message was successfully created.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
OMSA Event ID
2413
OMSA Trap ID
120100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC      
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC          
CMC              

VDR109

Message
Successfully deleted Controller Enhanced cache ( arg1 ).
Arguments
  • arg1 = virtual disk name
Detailed Description
The Controller Enhanced cache identified in the message was successfully deleted.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
OMSA Event ID
2414
OMSA Trap ID
120100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC      
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC          
CMC              

VDR11

Message
arg1 has started initializing.
Arguments
  • arg1 = virtual disk
Detailed Description
This message is generated after initialization of a virtual disk starts.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2061
OMSA Trap ID
120100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*        

VDR110

Message
Unrecoverable storage medium error detected on arg1 .
Arguments
  • arg1 = virtual disk name
Detailed Description
This alert is generated when an unrecoverable storage medium error is detected on the virtual disk. This error can be a prelude to the physical disk becoming non-functional.
Recommended Response Action
Make sure a hot spare to the Virtual Disk identified in the message is available and back up the data on the virtual disk.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 1 (Critical)
OMSA Event ID
2417
OMSA Trap ID
120400
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC      
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC          
CMC              

VDR111

Message
Corrected disk storage medium error on arg1 .
Arguments
  • arg1 = virtual disk name
Detailed Description
The controller corrected a disk storage medium error on one of the participating physical disks of the virtual disk identified in the message.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
OMSA Event ID
2418
OMSA Trap ID
120100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC      
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC          
CMC              

VDR112

Message
Deleted the arg1 .
Arguments
  • arg1 = virtual disk
Detailed Description
The controller removed a virtual disk because of a delete virtual disk operation or a reset configuration operation.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 2 (Warning)
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC      
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC          
CMC              

VDR113

Message
Controller preserved cache was discarded by user for arg1 .
Arguments
  • arg1 = virtual disk
Detailed Description
This message occurs if the controller pinned cache is discarded for a virtual disk by user.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
LCD Message
Cache discarded for a virtual disk
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC   ✔* ✔*  
CMC            
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔* ✔*          
CMC ✔*          

VDR12

Message
Reconfiguration has started for arg1 .
Arguments
  • arg1 = virtual disk
Detailed Description
This message is generated after reconfiguration of a virtual disk starts.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2063
OMSA Trap ID
120100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*        

VDR13

Message
arg1 rebuild has started.
Arguments
  • arg1 = VD Name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2064
OMSA Trap ID
120100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*         ✔*

VDR14

Message
The consistency check on arg1 was cancelled.
Arguments
  • arg1 = virtual disk
Detailed Description
A user cancelled the consistency check operation for a virtual disk.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2067
OMSA Trap ID
120100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*         ✔*

VDR15

Message
Initialization of arg1 was cancelled.
Arguments
  • arg1 = virtual disk
Detailed Description
The initialization operation could not be completed. This may be due to a user action or a physical disk failure.
Recommended Response Action
If a physical disk failed, then replace the physical disk. Restart the virtual disk initialization.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2070
OMSA Trap ID
120100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*         ✔*

VDR16

Message
Consistency check of arg1 failed.
Arguments
  • arg1 = virtual disk
Detailed Description
A physical disk included in the virtual disk failed or there is an error in the parity information. A failed physical disk causes errors in parity information.
Recommended Response Action
Check that all the physical disks of the virtual disk are in a healthy condition. Replace any disks that are not healthy and restart the operation. If this is not the problem, delete the virtual disk and restore the data to the disk from a backup copy.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4353
OMSA Event ID
2076
OMSA Trap ID
120400
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*         ✔*

VDR17

Message
arg1 format failed.
Arguments
  • arg1 = VD Name
Detailed Description
A physical disk included in the virtual disk failed.
Recommended Response Action
Replace the failed physical disk. Identify the failed physical disk by locating the disk that has a red "X" for its status. Rebuild the physical disk. When finished, restart the virtual disk format operation.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4353
OMSA Event ID
2077
OMSA Trap ID
120400
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*         ✔*

VDR18

Message
Initialization of arg1 has failed.
Arguments
  • arg1 = virtual disk
Detailed Description
A physical disk included in the virtual disk has failed or was removed.
Recommended Response Action
If a physical disk has failed, replace the physical disk. Restart the virtual disk initialization.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4353
OMSA Event ID
2079
OMSA Trap ID
120400
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*         ✔*

VDR19

Message
Reconfiguration of arg1 has failed.
Arguments
  • arg1 = virtual disk
Detailed Description
The reconfiguration operation was not completed. This may be due to a user action or a physical disk failure.
Recommended Response Action
Recreate the virtual disk and restore data from a backup copy.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4353
OMSA Event ID
2081
OMSA Trap ID
120400
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*         ✔*

VDR2

Message
arg1 returned to optimal state.
Arguments
  • arg1 = virtual disk
Detailed Description
The virtual disk has returned to a healthy state and is working properly.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*         ✔*

VDR20

Message
arg1 rebuild failed.
Arguments
  • arg1 = VD Name
Detailed Description
A physical disk included in the virtual disk has failed or is corrupt. You may also have cancelled the rebuild.
Recommended Response Action
Replace the failed or corrupt disk. You can identify a disk that has failed by locating the disk that has a red "X" for its status. Restart the virtual disk rebuild.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 1 (Critical)
Trap/EventID
4353
OMSA Event ID
2082
OMSA Trap ID
120400
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC            
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC   ✔*         ✔*

VDR21

Message
Consistency check for arg1 has completed.
Arguments
  • arg1 = virtual disk
Detailed Description
This message is generated after a consistency check completes on a virtual disk.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2085
OMSA Trap ID
120100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*         ✔*

VDR22

Message
Formatting the arg1 is completed.
Arguments
  • arg1 = VD Name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (VDR = Virtual Disk)
Severity
Severity 3 (Informational)
Trap/EventID
4355
OMSA Event ID
2086
OMSA Trap ID
120100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*         ✔*

본 콘텐츠를 평가해주십시오.

정확함
유용함
이해하기 쉬운
이 문서가 도움이 되셨나요?
0/3000 characters
  평점(별 1~5개)을 매겨주십시오.
  평점(별 1~5개)을 매겨주십시오.
  평점(별 1~5개)을 매겨주십시오.
  문서가 도움이 되었는지 여부를 선택하십시오.
  의견에는 <>()\와 같은 특수 문자를 사용할 수 없습니다.