메인 콘텐츠로 이동
  • 빠르고 간편하게 주문
  • 주문 보기 및 배송 상태 추적
  • 제품 목록을 생성 및 액세스
  • 회사 관리를 사용하여 Dell EMC 사이트, 제품 및 제품 수준 연락처를 관리하십시오.

Event and Error Message Reference Guide For 13th Generation Dell PowerEdge Servers Version 1.50

SSD Event Messages

SSD1001

Message
Write-cache on arg1 is enabled.
Arguments
  • arg1 = PCIe SSD name
Detailed Description
Write-cache is enabled on the PCIe solid state drive (SSD) identified in the message.
Recommended Response Action
No response action is required.
Category
Storage (SSD = SSD Devices)
Severity
Severity 2 (Warning)
OMSA Event ID
2427
OMSA Trap ID
90300
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC      
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC          
CMC              

SSD1002

Message
Write-cache on arg1 is disabled.
Arguments
  • arg1 = PCIe SSD name
Detailed Description
Write-cache is disabled on the PCIe solid state drive (SSD) identified in the message.
Recommended Response Action
No response action is required.
Category
Storage (SSD = SSD Devices)
Severity
Severity 2 (Warning)
OMSA Event ID
2428
OMSA Trap ID
90300
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC      
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC          
CMC              

SSD1003

Message
arg1 is ready for removal.
Arguments
  • arg1 = PCIe SSD name
Detailed Description
The PCIe solid state drive (SSD) identified in the message is ready for removal.
Recommended Response Action
No response action is required.
Category
Storage (SSD = SSD Devices)
Severity
Severity 3 (Informational)
OMSA Event ID
2429
OMSA Trap ID
90100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC      
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC          
CMC              

SSD1004

Message
Exported the arg1 log file.
Arguments
  • arg1 = PCIe SSD name
Detailed Description
The log file of the PCIe solid state drive (SSD) identified in the message is successfully exported.
Recommended Response Action
No response action is required.
Category
Storage (SSD = SSD Devices)
Severity
Severity 3 (Informational)
OMSA Event ID
2430
OMSA Trap ID
90100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC      
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC          
CMC              

SSD1005

Message
Successfully initialized arg1 .
Arguments
  • arg1 = PCIe SSD name
Detailed Description
The initialization of the PCIe solid state drive (SSD) identified in the message is complete.
Recommended Response Action
No response action is required.
Category
Storage (SSD = SSD Devices)
Severity
Severity 3 (Informational)
OMSA Event ID
2431
OMSA Trap ID
90100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC      
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC          
CMC              

SSD1006

Message
The arg1 has reached arg2 of warranted device wear-out limit.
Arguments
  • arg1 = PCIe solid state device name
  • arg2 = percent
Detailed Description
The PCIe solid state device identified in the message is approaching the warranted wear-out limit.
Recommended Response Action
No response action is required.
Category
Storage (SSD = SSD Devices)
Severity
Severity 3 (Informational)
OMSA Event ID
2433
OMSA Trap ID
90100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC      
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC          
CMC              

SSD1007

Message
The arg1 has reached or exceeded its warranted wear-out limit.
Arguments
  • arg1 = PCIe solid state device name
Detailed Description
The solid state device identified in the message has either reached or exceeded the warranted wear-out limit.
Recommended Response Action
Back up the data on the device, and contact your service provider for further instructions.
Category
Storage (SSD = SSD Devices)
Severity
Severity 2 (Warning)
OMSA Event ID
2434
OMSA Trap ID
90300
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC      
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC          
CMC              

SSD1008

Message
The arg1 is approaching read-only mode.
Arguments
  • arg1 = PCIe solid state device name
Detailed Description
The PCIe solid state device identified in the message is between 90% and 100% of reaching read-only mode.
Recommended Response Action
No response action is required.
Category
Storage (SSD = SSD Devices)
Severity
Severity 3 (Informational)
OMSA Event ID
2435
OMSA Trap ID
90100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC      
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC          
CMC              

SSD1009

Message
The arg1 is in read-only mode.
Arguments
  • arg1 = PCIe solid state device name
Detailed Description
The PCIe solid state device identified in the message is in read-only mode.
Recommended Response Action
Back up the data on the device, and contact your service provider for further instructions.
Category
Storage (SSD = SSD Devices)
Severity
Severity 1 (Critical)
OMSA Event ID
2436
OMSA Trap ID
90400
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC      
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC          
CMC              

SSD1010

Message
The arg1 is in a security locked state.
Arguments
  • arg1 = PCIe solid state device name
Detailed Description
The PCIe solid state device identified in the message is in a locked state, because an existing initialization task was interrupted due to a power failure or disk removal.
Recommended Response Action
Run Full Initialize operation on the device identified in the message.
Category
Storage (SSD = SSD Devices)
Severity
Severity 2 (Warning)
OMSA Event ID
2432
OMSA Trap ID
90200
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC      
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC          
CMC              

SSD1011

Message
The Remaining Rated Write Endurance Threshold for PCIe SSDs is set to arg1 .
Arguments
  • arg1 = value
Detailed Description
The Remaining Rated Write Endurance (RRWE) Threshold for PCIe solid state devices has been modified. A warning alert is generated when the RRWE for any PCIeSSD device falls below the user set RRWE Threshold value.
Recommended Response Action
No response action is required.
Category
Storage (SSD = SSD Devices)
Severity
Severity 3 (Informational)
OMSA Event ID
2449
OMSA Trap ID
10100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC      
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC          
CMC              

SSD1012

Message
The Remaining Rated Write Endurance Threshold for SAS and SATA SSDs is set to arg1 .
Arguments
  • arg1 = value
Detailed Description
The Remaining Rated Write Endurance (RRWE) Threshold for SAS and SATA solid state devices has been modified. A warning alert when the RRWE for any SAS or SATA SSD falls below the threshold set by the user.
Recommended Response Action
No response action is required.
Category
Storage (SSD = SSD Devices)
Severity
Severity 3 (Informational)
OMSA Event ID
2448
OMSA Trap ID
10100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC      
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC          
CMC              

본 콘텐츠를 평가해주십시오.

정확함
유용함
이해하기 쉬운
이 문서가 도움이 되셨나요?
0/3000 characters
  평점(별 1~5개)을 매겨주십시오.
  평점(별 1~5개)을 매겨주십시오.
  평점(별 1~5개)을 매겨주십시오.
  문서가 도움이 되었는지 여부를 선택하십시오.
  의견에는 <>()\와 같은 특수 문자를 사용할 수 없습니다.