Event and Error Message Reference Guide For 13th Generation Dell PowerEdge Servers Version 1.50

MEM Event Messages

MEM0000

Message
Persistent correctable memory errors detected on a memory device at location(s) arg1 .
Arguments
  • arg1 = location
Detailed Description
The memory is operational. This is an early indicator of a possible future uncorrectable error.
Recommended Response Action
Re-install the memory component. If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (MEM = Memory)
Severity
Severity 2 (Warning)
Trap/EventID
2266
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

MEM0001

Message
Multi-bit memory errors detected on a memory device at location(s) arg1 .
Arguments
  • arg1 = location
Detailed Description
The memory has encountered a uncorrectable error. System performance may be degraded. The operating system and/or applications may fail as a result.
Recommended Response Action
Re-install the memory component. If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (MEM = Memory)
Severity
Severity 1 (Critical)
Trap/EventID
2265
LCD Message
Multi-bit memory error on <location>. Reseat memory
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

MEM0002

Message
Parity memory errors detected on a memory device at location arg1 .
Arguments
  • arg1 = location
Detailed Description
The memory is operational. This is an early indicator of a possible future uncorrectable error.
Recommended Response Action
Re-install the memory component. If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (MEM = Memory)
Severity
Severity 1 (Critical)
Trap/EventID
2265
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

MEM0003

Message
Stuck bit memory error detected on a memory device at location arg1 .
Arguments
  • arg1 = location
Detailed Description
The memory is operational. This is an early indicator of a possible future uncorrectable error.
Recommended Response Action
Re-install the memory component. If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (MEM = Memory)
Severity
Severity 1 (Critical)
Trap/EventID
2265
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

MEM0004

Message
Memory device at location arg1 is disabled.
Arguments
  • arg1 = location
Detailed Description
The memory may not be seated correctly, misconfigured, or has failed. Memory size is reduced.
Recommended Response Action
Re-install the memory component. Review product documentation for supported memory configurations. If the problem continues, contact support.
Category
System Health (MEM = Memory)
Severity
Severity 1 (Critical)
Trap/EventID
2265
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

MEM0005

Message
Persistent correctable memory error limit reached for a memory device at location(s) arg1 .
Arguments
  • arg1 = location
Detailed Description
The memory is operational. This is an early indicator of a possible future uncorrectable error.
Recommended Response Action
Re-install the memory component. If the problem persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (MEM = Memory)
Severity
Severity 1 (Critical)
Trap/EventID
2265
LCD Message
Persistent correctable memory error limit reached for <location>. Reseat memory.
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

MEM0006

Message
Memory device at location arg1 is present.
Arguments
  • arg1 = location
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Severity 3 (Informational)
Trap/EventID
2267
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

MEM0007

Message
Unsupported memory configuration; check memory device at location arg1 .
Arguments
  • arg1 = location
Detailed Description
The memory may not be seated correctly, misconfigured, or has failed. Memory size is reduced.
Recommended Response Action
Review product documentation for supported memory configurations
Category
System Health (MEM = Memory)
Severity
Severity 1 (Critical)
Trap/EventID
2265
LCD Message
Unsupported memory configuration. Check memory <location>.
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

MEM0008

Message
Memory device at location arg1 is spare memory.
Arguments
  • arg1 = location
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Severity 3 (Informational)
Trap/EventID
2267
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

MEM0009

Message
Memory device at location arg1 is throttled.
Arguments
  • arg1 = location
Detailed Description
System performance is degraded.
Recommended Response Action
If unexpected, review system logs for power or thermal exceptions.
Category
System Health (MEM = Memory)
Severity
Severity 2 (Warning)
Trap/EventID
2266
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

MEM0010

Message
Memory device at location arg1 is overheating.
Arguments
  • arg1 = location
Detailed Description
System performance is degraded.
Recommended Response Action
If unexpected, review system logs for power or thermal exceptions.
Category
System Health (MEM = Memory)
Severity
Severity 1 (Critical)
Trap/EventID
2265
LCD Message
Memory device <location> is over heating. Check fans
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

MEM0016

Message
Memory device at location(s) arg1 is operating correctly.
Arguments
  • arg1 = location
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Severity 3 (Informational)
Trap/EventID
2267
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

MEM0020

Message
Memory device at location arg1 is enabled.
Arguments
  • arg1 = location
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Severity 3 (Informational)
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

MEM0021

Message
Persistent correctable memory error limit reset for a memory device at location arg1 .
Arguments
  • arg1 = location
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Severity 3 (Informational)
Trap/EventID
2267
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

MEM0022

Message
Memory device at location arg1 is absent.
Arguments
  • arg1 = location
Detailed Description
The memory may not be seated correctly, misconfigured, or has failed. Memory size is reduced.
Recommended Response Action
If unexpected, check presence, then re-install.
Category
System Health (MEM = Memory)
Severity
Severity 2 (Warning)
Trap/EventID
2266
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

MEM0024

Message
Memory device at location arg1 is no longer spare memory.
Arguments
  • arg1 = location
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Severity 3 (Informational)
Trap/EventID
2267
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

MEM0600

Message
Memory device was added at location arg1 .
Arguments
  • arg1 = location
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Severity 3 (Informational)
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

MEM0601

Message
Memory device is removed from location arg1 .
Arguments
  • arg1 = location
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Severity 3 (Informational)
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

MEM0700

Message
The persistent correctable memory error rate is at normal levels for a memory device at location arg1 .
Arguments
  • arg1 = location
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Severity 3 (Informational)
Trap/EventID
2267
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

MEM0701

Message
Correctable memory error rate exceeded for arg1 .
Arguments
  • arg1 = location
Detailed Description
The memory may not be operational. This an early indicator of a possible future uncorrectable error.
Recommended Response Action
Re-install the memory component. If the problem continues, contact support.
Category
System Health (MEM = Memory)
Severity
Severity 2 (Warning)
Trap/EventID
2266
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

MEM0702

Message
Correctable memory error rate exceeded for arg1 .
Arguments
  • arg1 = location
Detailed Description
The memory may not be operational. This an early indicator of a possible future uncorrectable error.
Recommended Response Action
Re-install the memory component. If the problem continues, contact support.
Category
System Health (MEM = Memory)
Severity
Severity 1 (Critical)
Trap/EventID
2265
LCD Message
Correctable memory error rate exceeded for <location>. Reseat memory.
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

MEM1000

Message
Memory device at location arg1 transition to a running state.
Arguments
  • arg1 = location
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Severity 3 (Informational)
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

MEM1001

Message
Memory device at location arg1 failed to transition to a running state.
Arguments
  • arg1 = location
Detailed Description
None
Recommended Response Action
Re-install the memory component. If the problem continues, contact support.
Category
System Health (MEM = Memory)
Severity
Severity 1 (Critical)
LCD Message
Memory device <location> failed to transition to a running state. Reseat memory
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

MEM1002

Message
Memory device at location arg1 is in test.
Arguments
  • arg1 = location
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Severity 3 (Informational)
Trap/EventID
2267
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

MEM1003

Message
Memory device at location arg1 failed to transition to in test.
Arguments
  • arg1 = location
Detailed Description
None
Recommended Response Action
Re-install the memory component. If the problem continues, contact support.
Category
System Health (MEM = Memory)
Severity
Severity 2 (Warning)
Trap/EventID
2266
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

MEM1004

Message
Memory device at location arg1 is powered off.
Arguments
  • arg1 = location
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Severity 3 (Informational)
Trap/EventID
2267
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

MEM1005

Message
Memory device at location arg1 failed to power off.
Arguments
  • arg1 = location
Detailed Description
None
Recommended Response Action
Re-attempt memory removal process
Category
System Health (MEM = Memory)
Severity
Severity 1 (Critical)
Trap/EventID
2265
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

MEM1006

Message
Memory device at location arg1 is online.
Arguments
  • arg1 = location
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Severity 3 (Informational)
Trap/EventID
2267
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

MEM1007

Message
Memory device at location arg1 failed to transition to online.
Arguments
  • arg1 = location
Detailed Description
None
Recommended Response Action
Re-attempt memory removal process
Category
System Health (MEM = Memory)
Severity
Severity 1 (Critical)
Trap/EventID
2265
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

MEM1008

Message
Memory device at location arg1 is offline.
Arguments
  • arg1 = location
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Severity 3 (Informational)
Trap/EventID
2267
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

MEM7002

Message
A hardware mismatch detected for memory riser.
Detailed Description
None
Recommended Response Action
Review product documentation for proper memory riser installation and configuration
Category
System Health (MEM = Memory)
Severity
Severity 1 (Critical)
Trap/EventID
2265
LCD Message
Memory riser mismatch detected. Check memory riser
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

MEM8000

Message
Correctable memory error logging disabled for a memory device at location arg1 .
Arguments
  • arg1 = location
Detailed Description
Errors are being corrected but no longer logged.
Recommended Response Action
Review system logs for memory exceptions. Re-install memory at location <location>
Category
System Health (MEM = Memory)
Severity
Severity 1 (Critical)
Trap/EventID
2265
LCD Message
SBE log disabled on <location>. Reseat memory
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

MEM8001

Message
Persistent correctable memory error logging enabled for a memory device at location arg1 .
Arguments
  • arg1 = location
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Severity 3 (Informational)
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

MEM8500

Message
Low memory condition detected.
Detailed Description
A low memory condition was detected. If this condition continues, a failover or a reset may occur. If multiple resets occur, contact your service provider.
Recommended Response Action
If multiple resets occur, contact Service.
Category
Audit (MEM = Memory)
Severity
Severity 1 (Critical)
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

MEM8501

Message
Low memory warning, arg1 KB, arg2 KB.
Arguments
  • arg1 = total memory size
  • arg2 = threshold value
Detailed Description
A low memory condition was detected. If this condition continues, a failover or a reset may occur.
Recommended Response Action
If multiple resets occur, contact your service provider.
Category
Audit (MEM = Memory)
Severity
Severity 2 (Warning)
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

MEM8502

Message
ECC Memory error rate failover condition detected.
Detailed Description
An ECC memory condition was detected on the primary CMC and a failover was initiated.
Recommended Response Action
Reseat the primary CMC and initiate a failover back to the primary CMC. If the problem persists and multiple failovers occur, contact your service provider. .
Category
Audit (MEM = Memory)
Severity
Severity 1 (Critical)
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC ✔*           ✔*

MEM9000

Message
Memory interconnect degraded.
Detailed Description
An issue is detected in the propagation of signals between the processor and the memory.
Recommended Response Action
Do one of the following: 1) Reseat the memory riser and restart the server. 2) If the issue is not resolved by preceding action, reseat the processor and restart the server. 3) If the issue persists, contact your service provider.
Category
System Health (MEM = Memory)
Severity
Severity 1 (Critical)
Trap/EventID
2265
LCD Message
Memory interconnect degraded. Reseat memory riser.
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

MEM9001

Message
Memory interconnect is functioning normally.
Detailed Description
The memory interconnect is functioning normally.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Severity 3 (Informational)
LCD Message
Memory interconnect normal.
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC      
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

MEM9002

Message
Intel QPI interconnect arg1 has a correctable error.
Arguments
  • arg1 = QPI link number
Detailed Description
A correctable error was detected in propagation of signals between processors through the Intel QPI interconnect interconnect identified in the message.
Recommended Response Action
Do one of the following: 1) Restart the server and check whether the issue persists. 2) If the issue is not resolved by the preceding action, reseat the processors and restart the server. 3) If the issue persists, contact your service provider.
Category
System Health (MEM = Memory)
Severity
Severity 2 (Warning)
Trap/EventID
2266
LCD Message
Intel QPI interconnect <number> has a correctable error.
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

MEM9003

Message
Intel SMI 2 Memory interconnect arg1 has a correctable error.
Arguments
  • arg1 = link number
Detailed Description
A correctable error was detected in propagation of signals between processor and memory through the Intel SMI 2 memory interconnect identified in the message.
Recommended Response Action
Do one of the following: 1) Reseat the memory riser and restart the server. 2) If the issue is not resolved by preceding action, reseat the processor and restart the server. 3) If the issue persists, contact your services provider.
Category
System Health (MEM = Memory)
Severity
Severity 2 (Warning)
Trap/EventID
2266
LCD Message
Intel SMI 2 Memory interconnect <number> has a correctable error.
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

MEM9004

Message
Intel QPI interconnect arg1 has degraded.
Arguments
  • arg1 = QPI link number
Detailed Description
A link degradation was detected in propagation of signals between processors through the Intel QPI interconnect interconnect identified in the message. The system will continue to operate at reduced performance.
Recommended Response Action
Do one of the following: 1) Restart the server and check whether the issue persists. 2) If the issue is not resolved by the preceding action, reseat the processors and restart the server. 3) If the issue persists, contact your service provider.
Category
System Health (MEM = Memory)
Severity
Severity 1 (Critical)
Trap/EventID
2265
LCD Message
Intel QPI interconnect <number> has degraded. Reseat processor.
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

MEM9005

Message
Intel SMI 2 Memory interconnect arg1 has degraded.
Arguments
  • arg1 = link number
Detailed Description
A link degradation was detected in propagation of signals between processor and memory through the Intel SMI 2 memory interconnect identified in the message.
Recommended Response Action
Do one of the following: 1) Reseat the memory riser and restart the server. 2) If the issue is not resolved by preceding action, reseat the processor and restart the server. 3) If the issue persists, contact your service provider.
Category
System Health (MEM = Memory)
Severity
Severity 1 (Critical)
Trap/EventID
2265
LCD Message
Intel SMI 2 interconnect <number> degraded. Reseat memory riser.
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

MEM9006

Message
Intel QPI interconnect arg1 has a non-recoverable issue.
Arguments
  • arg1 = QPI link number
Detailed Description
A non-recoverable link issue was detected in propagation of signals between processors through the Intel QPI interconnect interconnect identified in the message.
Recommended Response Action
Do one of the following: 1) Restart the server and check whether the issue persists. 2) If the issue is not resolved by the preceding action, reseat the processors and restart the server. 3) If the issue persists, contact your service provider.
Category
System Health (MEM = Memory)
Severity
Severity 1 (Critical)
Trap/EventID
2265
LCD Message
Intel QPI interconnect <number> has fatal error. Reseat memory riser.
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

MEM9007

Message
Intel SMI 2 Memory interconnect arg1 has a non-recoverable issue.
Arguments
  • arg1 = link number
Detailed Description
A non-recoverable link issue was detected in propagation of signals between processor and memory through the Intel SMI 2 memory interconnect identified in the message.
Recommended Response Action
Do one of the following: 1) Reseat the memory riser and restart the server. 2) If the issue is not resolved by preceding action, reseat the processor and restart the server. 3) If the issue persists, contact your service provider.
Category
System Health (MEM = Memory)
Severity
Severity 1 (Critical)
Trap/EventID
2265
LCD Message
Intel SMI 2 interconnect <number> has fatal error. Reseat mem riser.
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

MEM9008

Message
Intel DDR Memory interconnect arg1 has a non-recoverable issue.
Arguments
  • arg1 = link number
Detailed Description
A non-recoverable issue was detected in the propagation of signals on the Intel DDR memory interconnect identified in the message.
Recommended Response Action
Reseat all DIMMs on the memory riser, reseat the memory riser, and restart the server. If the issue persists, contact your service provider.
Category
System Health (MEM = Memory)
Severity
Severity 1 (Critical)
Trap/EventID
2265
LCD Message
Intel DDR interconnect <number> has fatal error. Reseat mem riser.
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

MEM9009

Message
Intel DDR Memory interconnect arg1 has a correctable error.
Arguments
  • arg1 = link number
Detailed Description
A correctable error was detected in the propagation of signals on the Intel DDR memory interconnect identified in the message.
Recommended Response Action
Do the following: 1) Reseat all DIMMs on the memory riser, 2) Reseat the memory riser, and 3) Restart the server. If the issue persists, contact your service provider.
Category
System Health (MEM = Memory)
Severity
Severity 2 (Warning)
Trap/EventID
2266
LCD Message
Intel DDR interconnect <number> has a correctable error. Reseat mem riser.
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC    
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

MEM9010

Message
A QuickPath Interconnect (QPI) Reference Code warning message code is logged.
Detailed Description
BIOS logged the major and minor code of a QuickPath Interconnect (QPI) Reference Code warning. This information can be reviewed by using a tool which displays raw IPMI SEL log data such as IPMItool with the -vvv option or RACADM with the -E option.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Severity 3 (Informational)
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

MEM9011

Message
QuickPath Interconnect (QPI) Reference Code warning location information is logged.
Detailed Description
BIOS logged location information of a QuickPath Interconnect (QPI) warning. This information can be reviewed by using a tool which displays raw IPMI SEL data such as IPMItool with the -vvv option or RACADM with the -E option.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Severity 2 (Warning)
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

MEM9012

Message
A Memory Reference Code (MRC) warning code is logged.
Detailed Description
BIOS logged the major and minor code of a Memory Reference Code (MRC) warning. This information can be reviewed by using a tool which displays raw IPMI SEL data such as IPMIitool with the -vvv option or RACADM with the -E option.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Severity 3 (Informational)
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

MEM9013

Message
Memory Reference Code (MRC) warning location information is logged.
Detailed Description
BIOS logged location information of a Memory Reference Code (MRC) warning. This information can be reviewed by using a tool which displays raw IPMI SEL data such as IPMItool with the -vvv option or RACADM with the -E option.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Severity 2 (Warning)
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC              
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC              

MEM9014

Message
A correctable memory error has occurred in Dual In-line Memory Module (DIMM) device arg1 .
Arguments
  • arg1 = location
Detailed Description
The memory device identified in the message has encountered a correctable memory error. This may be an early indicator of a possible future uncorrectable error.
Recommended Response Action
This is a correctable error. Review log information and if multiple correctable errors have occurred on the DIMM identified in the message, re-install the memory device. If the issue persists, contact your service provider.
Category
System Health (MEM = Memory)
Severity
Severity 2 (Warning)
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

MEM9015

Message
Multi-bit memory errors detected on a Dual In-line Memory Module (DIMM) device arg1 .
Arguments
  • arg1 = location
Detailed Description
The memory device identified in the message has encountered a uncorrectable error. System performance may be degraded. The operating system and/or applications may fail as a result.
Recommended Response Action
Re-install the memory component identified in the message. If the issue persists, contact your service provider. Refer to the product documentation to choose a convenient contact method.
Category
System Health (MEM = Memory)
Severity
Severity 1 (Critical)
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

MEM9016

Message
Correctable memory error rate exceeded for Dual In-line Memory Module (DIMM) arg1 .
Arguments
  • arg1 = location
Detailed Description
The memory device identified in the message may not be operational. This an early indicator of a possible future uncorrectable error.
Recommended Response Action
Re-install the memory component identified in the message. If the issue persists, contact your service provider. Refer to the product documentation to choose a convenient contact method.
Category
System Health (MEM = Memory)
Severity
Severity 2 (Warning)
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

본 콘텐츠를 평가해주십시오.

정확함
유용함
이해하기 쉬운
이 문서가 도움이 되셨나요?
0/3000 characters
  평점(별 1~5개)을 매겨주십시오.
  평점(별 1~5개)을 매겨주십시오.
  평점(별 1~5개)을 매겨주십시오.
  문서가 도움이 되었는지 여부를 선택하십시오.
  의견에는 <>()\와 같은 특수 문자를 사용할 수 없습니다.