Event and Error Message Reference Guide For 13th Generation Dell PowerEdge Servers Version 1.50

FAN Event Messages

FAN0000

Message
Fan arg1 RPM is less than the lower warning threshold.
Arguments
  • arg1 = number
Detailed Description
The fan is not performing optimally. The fan may be installed improperly or may be failing.
Recommended Response Action
Remove and re-install the fan at the next scheduled service window. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (FAN = Fan Event)
Severity
Severity 2 (Warning)
Trap/EventID
2154
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC ✔*
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*            

FAN0001

Message
Fan arg1 RPM is less than the lower critical threshold.
Arguments
  • arg1 = number
Detailed Description
The fan is not performing optimally. The fan may be installed improperly or may be failing.
Recommended Response Action
Remove and re-install the fan. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (FAN = Fan Event)
Severity
Severity 1 (Critical)
Trap/EventID
2153
LCD Message
Fan <number> RPM is outside of range. Check fan.
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC ✔*
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*            

FAN0002

Message
Fan arg1 RPM is greater than the upper warning threshold.
Arguments
  • arg1 = number
Detailed Description
The fan is not performing optimally. The fan may be installed improperly or may be failing.
Recommended Response Action
Remove and re-install the fan at the next scheduled service window. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (FAN = Fan Event)
Severity
Severity 2 (Warning)
Trap/EventID
2154
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC ✔*
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*            

FAN0003

Message
Fan arg1 RPM is greater than the upper critical threshold.
Arguments
  • arg1 = number
Detailed Description
The fan is not performing optimally. The fan may be installed improperly or may be failing.
Recommended Response Action
Remove and re-install the fan. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (FAN = Fan Event)
Severity
Severity 1 (Critical)
Trap/EventID
2153
LCD Message
Fan <number> RPM is outside of range. Check fan.
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC ✔*
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*            

FAN0004

Message
Fan arg1 RPM is outside of range.
Arguments
  • arg1 = number
Detailed Description
The fan is not performing optimally. The fan may be installed improperly or may be failing.
Recommended Response Action
Remove and re-install the fan. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (FAN = Fan Event)
Severity
Severity 1 (Critical)
Trap/EventID
2153
LCD Message
Fan <number> RPM is outside of range. Check fan.
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC ✔*
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*            

FAN0005

Message
Fan arg1 RPM is within range.
Arguments
  • arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (FAN = Fan Event)
Severity
Severity 3 (Informational)
Trap/EventID
2155
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC ✔*
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*            

FAN0006

Message
Fan arg1 is removed.
Arguments
  • arg1 = number
Detailed Description
The fan may be required for optimal performance.
Recommended Response Action
If unintentional, install a fan.
Category
System Health (FAN = Fan Event)
Severity
Severity 1 (Critical)
Trap/EventID
2153
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*            

FAN0007

Message
Fan arg1 was inserted.
Arguments
  • arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (FAN = Fan Event)
Severity
Severity 3 (Informational)
Trap/EventID
2155
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*            

FAN0008

Message
Fan arg1 is present.
Arguments
  • arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (FAN = Fan Event)
Severity
Severity 3 (Informational)
Trap/EventID
2155
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

FAN0009

Message
Fan arg1 is absent.
Arguments
  • arg1 = number
Detailed Description
The fan may be required for optimal performance.
Recommended Response Action
If unintentional, install a fan.
Category
System Health (FAN = Fan Event)
Severity
Severity 1 (Critical)
Trap/EventID
2153
LCD Message
Fan <number> is absent. Check Fan.
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

FAN0010

Message
Fan arg1 is disabled.
Arguments
  • arg1 = number
Detailed Description
The fan may be required for optimal performance.
Recommended Response Action
No response action is required.
Category
System Health (FAN = Fan Event)
Severity
Severity 2 (Warning)
Trap/EventID
2154
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

FAN0011

Message
Fan arg1 is enabled.
Arguments
  • arg1 = number
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (FAN = Fan Event)
Severity
Severity 3 (Informational)
Trap/EventID
2155
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

FAN0012

Message
arg1 RPM is less than the lower warning threshold.
Arguments
  • arg1 = fan name
Detailed Description
The device is not performing optimally. The device may be installed improperly.
Recommended Response Action
Remove and re-install the device at the next scheduled service. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (FAN = Fan Event)
Severity
Severity 2 (Warning)
Trap/EventID
2154
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC   ✔*        
CMC ✔*           ✔*

FAN0013

Message
arg1 RPM is less than the lower critical threshold.
Arguments
  • arg1 = fan name
Detailed Description
The cooling device is not performing optimally. The cooling device may be installed improperly.
Recommended Response Action
Remove and re-install the cooling device. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (FAN = Fan Event)
Severity
Severity 1 (Critical)
Trap/EventID
2153
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

FAN0014

Message
arg1 RPM is greater than the upper warning threshold.
Arguments
  • arg1 = fan name
Detailed Description
The cooling device is not performing optimally. The cooling device may be installed improperly.
Recommended Response Action
Remove and re-install the cooling device. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (FAN = Fan Event)
Severity
Severity 2 (Warning)
Trap/EventID
2154
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

FAN0015

Message
arg1 RPM is greater than the upper critical threshold.
Arguments
  • arg1 = fan name
Detailed Description
The cooling device is not performing optimally. The cooling device may be installed improperly.
Recommended Response Action
Remove and re-install the cooling device. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (FAN = Fan Event)
Severity
Severity 1 (Critical)
Trap/EventID
2153
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

FAN0016

Message
arg1 RPM is outside of normal operating range.
Arguments
  • arg1 = fan name
Detailed Description
The cooling device is not performing optimally. The cooling device may be installed improperly.
Recommended Response Action
Remove and re-install the cooling device. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (FAN = Fan Event)
Severity
Severity 1 (Critical)
Trap/EventID
2153
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

FAN0017

Message
arg1 RPM is within normal operating range.
Arguments
  • arg1 = fan name
Detailed Description
The RPM of the fan identified in the message is functioning correctly.
Recommended Response Action
No response action is required.
Category
System Health (FAN = Fan Event)
Severity
Severity 3 (Informational)
Trap/EventID
2155
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

FAN0018

Message
Enhanced Cooling Mode is not supported for fan arg1 .
Arguments
  • arg1 = fan number
Detailed Description
Enhanced Cooling Mode is not supported by the type of fan identified in the message.
Recommended Response Action
Replace the fan identified in the message with another fan which supports Enhanced Cooling Mode.
Category
System Health (FAN = Fan Event)
Severity
Severity 2 (Warning)
Redfish Event Type
Alert
No alerts are applicable for this message

FAN0019

Message
An incompatibility between operating mode and fan type was corrected for fan arg1 .
Arguments
  • arg1 = fan number
Detailed Description
An incompatibility between operating mode and fan type was corrected for the fan identified in the message.
Recommended Response Action
No response action is required.
Category
System Health (FAN = Fan Event)
Severity
Severity 3 (Informational)
Redfish Event Type
Alert
No alerts are applicable for this message

FAN0020

Message
The arg1 is non-functional.
Arguments
  • arg1 = fan name
Detailed Description
The fan identified in the message has failed or it is not installed correctly.
Recommended Response Action
Remove and re-install the fan or replace the fan, and open the OMSA Web interface to verify if the fan specified in the message is displayed correctly. If the issue persists, contact your service provider.
Category
System Health (FAN = Fan Event)
Severity
Severity 1 (Critical)
OMSA Event ID
5300
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC   ✔*        
CMC              

FAN0021

Message
arg1 is offline.
Arguments
  • arg1 = fan name
Detailed Description
The fan identified in the message is removed. However, the fan may be required for optimal system performance.
Recommended Response Action
Re-install the fan, and open the OMSA Web interface to verify if the fan identified in the message is displayed correctly. If the issue persists, contact your service provider.
Category
System Health (FAN = Fan Event)
Severity
Severity 3 (Informational)
OMSA Event ID
5303
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC   ✔*        
CMC              

FAN0022

Message
The arg1 sensor has failed, and the last recorded value by the sensor was arg2 RPM.
Arguments
  • arg1 = sensor name
  • arg2 = fan speed
Detailed Description
The sensor identified in the message has failed. The sensor may be required for optimal system performance.
Recommended Response Action
Check the Embedded System Management (ESM) Log for any sensor related faults. If the fan sensor has failed, replace the system board. For more information, contact your service provider.
Category
System Health (FAN = Fan Event)
Severity
Severity 1 (Critical)
OMSA Event ID
5100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC   ✔*        
CMC              

FAN0023

Message
Unable to read the arg1 sensor value.
Arguments
  • arg1 = sensor name
Detailed Description
The fan sensor identified in the message has failed or the fan has failed.
Recommended Response Action
Do the following: 1) Remove the old fan, install a new fan and power cycle the system to check if the fan is working properly, 2) Replace the system board if the fan sensor has failed. 3) If the issue persists, contact your service provider.
Category
System Health (FAN = Fan Event)
Severity
Severity 2 (Warning)
OMSA Event ID
5101
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC   ✔*        
CMC              

FAN0024

Message
The arg1 sensor returned to a normal state with a value of arg2 RPM.
Arguments
  • arg1 = sensor name
  • arg2 = fan speed
Detailed Description
The sensor identified in the message has returned to a normal state.
Recommended Response Action
No response action is required.
Category
System Health (FAN = Fan Event)
Severity
Severity 3 (Informational)
OMSA Event ID
5102
OMSA Trap ID
5102
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC     ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC   ✔*        
CMC              

FAN0025

Message
The arg1 sensor state has changed to a warning state with a value of arg2 RPM.
Arguments
  • arg1 = sensor name
  • arg2 = fan speed
Detailed Description
The fan identified in the message is not functioning correctly. The fan may be installed incorrectly or may be failing.
Recommended Response Action
Remove and re-install the fan, or replace the fan. If the issue persists, contact your service provider.
Category
System Health (FAN = Fan Event)
Severity
Severity 2 (Warning)
OMSA Event ID
5103
OMSA Trap ID
5103
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC     ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC   ✔*        
CMC              

FAN0026

Message
The arg1 sensor detected an error with a value of arg2 RPM.
Arguments
  • arg1 = sensor name
  • arg2 = fan speed
Detailed Description
The fan sensor identified in the message indicates that the related fan has exceeded critical RPM thresholds..
Recommended Response Action
Remove and re-install the fan, or replace the fan with a new fan. If the issue persists, contact your service provider.
Category
System Health (FAN = Fan Event)
Severity
Severity 1 (Critical)
OMSA Event ID
5104
OMSA Trap ID
5104
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC     ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC   ✔*        
CMC              

FAN0027

Message
The arg1 sensor has failed with a value of arg2 RPM.
Arguments
  • arg1 = sensor name
  • arg2 = fan speed
Detailed Description
The sensor identified in the message has failed. The sensor may be required for optimal system performance.
Recommended Response Action
Check the Embedded System Management (ESM) Log for any sensor related faults. If the fan sensor has failed, replace the system board. For more information, contact your service provider.
Category
System Health (FAN = Fan Event)
Severity
Severity 1 (Critical)
OMSA Event ID
5105
OMSA Trap ID
5105
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC     ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC   ✔*        
CMC              

FAN1000

Message
arg1 was removed.
Arguments
  • arg1 = Fan Sensor Name
Detailed Description
The enclosure detected that a fan was removed and the enclosure is no longer functioning in optimal condition..
Recommended Response Action
Re-insert the fan into the enclosure. Contact technical support if the issue persists.
Category
Storage (FAN = Fan Event)
Severity
Severity 1 (Critical)
Trap/EventID
4201
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*         ✔*

FAN1001

Message
arg1 has been inserted.
Arguments
  • arg1 = Fan Sensor Name
Detailed Description
The enclosure detected that a fan was inserted.
Recommended Response Action
No response action is required.
Category
Storage (FAN = Fan Event)
Severity
Severity 3 (Informational)
Trap/EventID
4203
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*         ✔*

본 콘텐츠를 평가해주십시오.

정확함
유용함
이해하기 쉬운
이 문서가 도움이 되셨나요?
0/3000 characters
  평점(별 1~5개)을 매겨주십시오.
  평점(별 1~5개)을 매겨주십시오.
  평점(별 1~5개)을 매겨주십시오.
  문서가 도움이 되었는지 여부를 선택하십시오.
  의견에는 <>()\와 같은 특수 문자를 사용할 수 없습니다.