Event and Error Message Reference Guide For 13th Generation Dell PowerEdge Servers Version 1.50

FAN Event Messages

FAN1002

Message
arg1 has failed.
Arguments
  • arg1 = Fan Sensor Name
Detailed Description
The enclosure detected that a fan has failed and the enclosure is no longer functioning in optimal condition..
Recommended Response Action
Contact technical support.
Category
Storage (FAN = Fan Event)
Severity
Severity 1 (Critical)
Trap/EventID
4201
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*         ✔*

FAN8500

Message
Enhanced Cooling Mode is Enabled
Detailed Description
Enabling Enhanced Cooling Mode will provide increased airflow capability to the blades by increasing the maximum allowable blower speed at the cost of increased power consumption.
Recommended Response Action
No response action is required.
Category
Audit (FAN = Fan Event)
Severity
Severity 3 (Informational)
Redfish Event Type
Alert
No alerts are applicable for this message

FAN8501

Message
Enhanced Cooling Mode is Disabled
Detailed Description
Disabling Enhanced Cooling Mode allows for reduced power consumption by reducing the maximum speed of the blowers while still providing sufficient blade airflow.
Recommended Response Action
No response action is required.
Category
Audit (FAN = Fan Event)
Severity
Severity 3 (Informational)
Redfish Event Type
Alert
No alerts are applicable for this message

FAN8502

Message
Unable to detect the blower arg1 because the blower may not be optimally operating.
Arguments
  • arg1 = blower name
Detailed Description
The current CMC firmware did not detect the blower identified in the message.
Recommended Response Action
Make sure that CMC is using the latest firmware, and then retry the operation.
Category
Audit (FAN = Fan Event)
Severity
Severity 3 (Informational)
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

FAN8503

Message
The Chassis was turned off because more than two internal fans stopped functioning.
Detailed Description
The Chassis was turned off because more than two Chassis internal fans stopped functioning. The fans with issues are identified in the CMC Hardware (System Event Log) and Chassis Logs.
Recommended Response Action
Make sure that the Chassis internal fans are functioning. At the command line interface (CLI), enter the following command to identify fans that are not functioning: "racadm getsel". Using the CMC Web GUI, select the chassis, click the Logs tab, and then select Hardware Log. Reinsert or replace fans that are not functioning correctly.
Category
Audit (FAN = Fan Event)
Severity
Severity 1 (Critical)
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

FAN900

Message
The Enhanced Cooling Mode is successfully enabled.
Detailed Description
The Enhanced Cooling Mode is successfully enabled.
Recommended Response Action
No response action required.
Category
Configuration (FAN = Fan Event)
Severity
Severity 2 (Warning)
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

FAN901

Message
The Enhanced Cooling Mode is successfully disabled.
Detailed Description
The Enhanced Cooling Mode is successfully disabled.
Recommended Response Action
No response action required.
Category
Configuration (FAN = Fan Event)
Severity
Severity 2 (Warning)
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

FAN902

Message
Cannot enable the Enhanced Cooling Mode because sufficient power is not available.
Detailed Description
The Enhanced Cooling Mode cannot be set because required power is not available.
Recommended Response Action
Add PSUs with higher power capability or remove Chassis components such as I/O Modules or servers until the power requirements have been lowered enough to enable the Enhanced Cooling Mode, and then retry the operation.
Category
Configuration (FAN = Fan Event)
Severity
Severity 2 (Warning)
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

FAN903

Message
Cannot enable the Enhanced Cooling Mode because an unsupported fan is inserted in the Chassis.
Detailed Description
The Enhanced Cooling Mode cannot be enabled because an unsupported fan is present in the Chassis.
Recommended Response Action
Insert a fan that is supported by the Chassis, and then retry the operation. For a list of fans that are supported by Chassis, see the Chassis Management Controller Users Guide.
Category
Configuration (FAN = Fan Event)
Severity
Severity 2 (Warning)
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

FAN904

Message
Cannot enable the Enhanced Cooling Mode because the Maximum Power Conservation Mode is enabled.
Detailed Description
The Enhanced Cooling Mode cannot be enabled because the Maximum Power Conservation Mode is enabled.
Recommended Response Action
Disable the Maximum Power Conservation Mode, and then retry the operation. To disable the mode by using CMC Web interface, click Chassis Overview > Power > Configuration. To disable the mode using the RACADM utility, run the command "racadm config -g cfgThermal -o cfgThermalEnhancedCoolingMode 0".
Category
Configuration (FAN = Fan Event)
Severity
Severity 2 (Warning)
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

FAN905

Message
Applying fan configuration settings. This may take several seconds.
Detailed Description
Applying fan configuration settings. This may take several seconds.
Recommended Response Action
No response action required.
Category
Configuration (FAN = Fan Event)
Severity
Severity 2 (Warning)
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

FAN906

Message
Changes are not made to the current settings.
Detailed Description
Changes are not made to the current settings.
Recommended Response Action
Make sure that changes are made to the settings and retry the operation.
Category
Configuration (FAN = Fan Event)
Severity
Severity 2 (Warning)
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

FAN907

Message
The Enhanced Cooling Mode feature is already enabled.
Detailed Description
The Enhanced Cooling Mode feature is already enabled.
Recommended Response Action
No response action required.
Category
Configuration (FAN = Fan Event)
Severity
Severity 2 (Warning)
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

FAN908

Message
The Enhanced Cooling Mode feature is already disabled.
Detailed Description
The Enhanced Cooling Mode feature is already disabled.
Recommended Response Action
No response action required.
Category
Configuration (FAN = Fan Event)
Severity
Severity 2 (Warning)
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

FAN911

Message
The attempt to enable the Enhanced Cooling Mode was not successful.
Detailed Description
The attempt to enable the Enhanced Cooling Mode (ECM) was not successful because ECM is already enabled or Gen3 fans are not present in the Chassis.
Recommended Response Action
Check whether or not the Enhanced Cooling Mode (ECM) is already enabled. Make sure there are Gen3 fans in the Chassis and retry the operation.
Category
Configuration (FAN = Fan Event)
Severity
Severity 2 (Warning)
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC              
CMC              

본 콘텐츠를 평가해주십시오.

정확함
유용함
이해하기 쉬운
이 문서가 도움이 되셨나요?
0/3000 characters
  평점(별 1~5개)을 매겨주십시오.
  평점(별 1~5개)을 매겨주십시오.
  평점(별 1~5개)을 매겨주십시오.
  문서가 도움이 되었는지 여부를 선택하십시오.
  의견에는 <>()\와 같은 특수 문자를 사용할 수 없습니다.