메인 콘텐츠로 이동
  • 빠르고 간편하게 주문
  • 주문 보기 및 배송 상태 추적
  • 제품 목록을 생성 및 액세스
  • 회사 관리를 사용하여 Dell EMC 사이트, 제품 및 제품 수준 연락처를 관리하십시오.

Event and Error Message Reference Guide For 13th Generation Dell PowerEdge Servers Version 1.50

BAT Event Messages

BAT0000

Message
The system board battery is low.
Detailed Description
System settings may be preserved if input power is not removed from the power supplies.
Recommended Response Action
Check the system board battery at the next service window.
Category
System Health (BAT = Battery Event)
Severity
Severity 2 (Warning)
Trap/EventID
2226
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC ✔*
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

BAT0001

Message
The system board battery is operating normally.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
2227
OMSA Event ID
5702
OMSA Trap ID
5702
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC ✔*
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

BAT0002

Message
The system board battery has failed.
Detailed Description
System settings may be preserved if input power is not removed from the power supplies.
Recommended Response Action
Check the system board battery.
Category
System Health (BAT = Battery Event)
Severity
Severity 1 (Critical)
Trap/EventID
2225
LCD Message
System board battery has failed. Check battery
OMSA Event ID
5704;5705
OMSA Trap ID
5704
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC ✔*
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

BAT0003

Message
The system board battery is present.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
2227
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC ✔*
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC ✔*           ✔*

BAT0004

Message
The system board battery is absent.
Detailed Description
System settings may be preserved if input power is not removed from the power supplies.
Recommended Response Action
Check the system board battery to confirm presence.
Category
System Health (BAT = Battery Event)
Severity
Severity 1 (Critical)
Trap/EventID
2225
LCD Message
System board battery is absent. Check battery
OMSA Event ID
5700
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC ✔*
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC ✔*           ✔*

BAT0005

Message
The storage battery is low.
Detailed Description
The system has to remain powered on to charge the battery.
Recommended Response Action
Allow the PERC RAID controller battery to charge. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (BAT = Battery Event)
Severity
Severity 2 (Warning)
Trap/EventID
2226
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC ✔*
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

BAT0006

Message
The storage battery is operating normally.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
2227
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC ✔*
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

BAT0007

Message
The storage battery has failed.
Detailed Description
The PERC RAID controller battery may have failed because of thermal exceptions.
Recommended Response Action
1) Verify the PERC RAID controller battery installation. 2) Check the system logs for thermal related issues.
Category
System Health (BAT = Battery Event)
Severity
Severity 1 (Critical)
Trap/EventID
2225
LCD Message
Storage battery has failed. Check battery.
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC ✔*
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

BAT0008

Message
The storage battery is present.
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
2227
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC ✔*
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

BAT0009

Message
The storage battery is absent.
Detailed Description
The PERC RAID controller battery may report absent due to disconnect or thermal exceptions.
Recommended Response Action
1) Verify the PERC RAID controller battery installation. 2) If installed, reseat or reconnect the battery and cables. 3) Check the system logs for thermal related issues.
Category
System Health (BAT = Battery Event)
Severity
Severity 1 (Critical)
Trap/EventID
2225
LCD Message
Storage battery is absent. Check battery.
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC ✔*
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

BAT0010

Message
The storage battery for disk drive bay arg1 is low.
Arguments
  • arg1 = bay
Detailed Description
The system has to remain powered on to charge the battery.
Recommended Response Action
Allow the PERC RAID controller battery for the associated bay to charge. If the issue persists, contact technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health (BAT = Battery Event)
Severity
Severity 2 (Warning)
Trap/EventID
2226
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC ✔*
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

BAT0011

Message
The storage battery for disk drive bay arg1 is operating normally.
Arguments
  • arg1 = bay
Detailed Description
None
Recommended Response Action
Verify the battery installation, check the system logs for thermal related issues.
Category
System Health (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
2227
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC ✔*
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

BAT0012

Message
The storage battery for disk drive bay arg1 has failed.
Arguments
  • arg1 = bay
Detailed Description
The PERC RAID controller battery may have failed because of thermal exceptions.
Recommended Response Action
1) Verify the PERC RAID controller battery installation for the associated bay. 2) Check the system logs for thermal related issues.
Category
System Health (BAT = Battery Event)
Severity
Severity 1 (Critical)
Trap/EventID
2225
LCD Message
Battery for disk drive bay <bay> has failed. Check battery.
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC ✔*
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

BAT0013

Message
The storage battery for disk drive bay arg1 is present.
Arguments
  • arg1 = bay
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
2227
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC ✔*
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

BAT0014

Message
The storage battery for disk drive bay arg1 is absent.
Arguments
  • arg1 = bay
Detailed Description
The PERC RAID controller battery may report absent due to disconnect or thermal exceptions.
Recommended Response Action
1) Verify the PERC RAID controller battery installation for the associated bay. 2) If installed, reseat or reconnect the battery and cables. 3) Check the system logs for thermal related issues.
Category
System Health (BAT = Battery Event)
Severity
Severity 1 (Critical)
Trap/EventID
2225
LCD Message
Battery for disk drive bay <bay> is absent. Check battery.
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC ✔*
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

BAT0015

Message
The arg1 battery is low.
Arguments
  • arg1 = name
Detailed Description
System settings may be preserved if input power is not removed from the power supplies.
Recommended Response Action
Check the battery at the next service window.
Category
System Health (BAT = Battery Event)
Severity
Severity 2 (Warning)
Trap/EventID
2226
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC ✔*
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

BAT0016

Message
The arg1 battery is operating normally.
Arguments
  • arg1 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
2227
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC ✔*
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

BAT0017

Message
The arg1 battery has failed.
Arguments
  • arg1 = name
Detailed Description
System settings may be preserved if input power is not removed from the power supplies.
Recommended Response Action
Check the battery.
Category
System Health (BAT = Battery Event)
Severity
Severity 1 (Critical)
Trap/EventID
2225
LCD Message
The <name> battery has failed. Check battery.
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC ✔*
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

BAT0018

Message
The arg1 battery is present.
Arguments
  • arg1 = name
Detailed Description
None
Recommended Response Action
No response action is required.
Category
System Health (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
2227
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC ✔*
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC              

BAT0019

Message
The arg1 battery is absent.
Arguments
  • arg1 = name
Detailed Description
System settings may be preserved if input power is not removed from the power supplies.
Recommended Response Action
Check the battery to confirm presence.
Category
System Health (BAT = Battery Event)
Severity
Severity 1 (Critical)
Trap/EventID
2225
LCD Message
The <name> battery is absent. Check battery.
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC ✔*
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*    
CMC              

BAT0030

Message
The system board battery is reading low.
Detailed Description
The system battery level is low, and if the input power is disconnected, the system settings will not be preserved.
Recommended Response Action
Replace the battery.
Category
System Health (BAT = Battery Event)
Severity
Severity 2 (Warning)
OMSA Event ID
5703
OMSA Trap ID
5703
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC     ✔*  
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC   ✔*        
CMC              

BAT0031

Message
The system board battery status is unknown.
Detailed Description
The system battery level is unknown, and if the input power is disconnected, the system settings will not be preserved.
Recommended Response Action
Replace the battery.
Category
System Health (BAT = Battery Event)
Severity
Severity 2 (Warning)
OMSA Event ID
5701
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC        
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC   ✔*        
CMC              

BAT1000

Message
Battery on arg1 is missing.
Arguments
  • arg1 = controller name
Detailed Description
The controller cannot communicate with the battery. The battery is absent or improperly connected. A battery with a weak or depleted charge may also cause this message.
Recommended Response Action
Verify that the device is present and then check the cables. See the storage hardware documentation to verify cabling. In addition check the connection to the controller battery and the battery health. A battery with a weak or depleted charge may cause this message.
Category
Storage (BAT = Battery Event)
Severity
Severity 2 (Warning)
Trap/EventID
4274
OMSA Event ID
2264
OMSA Trap ID
75300;80300;85300;90300;95300;100300;105300;110300;115300;120300
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*         ✔*

BAT1001

Message
Battery on arg1 was replaced.
Arguments
  • arg1 = controller name
Detailed Description
A controllers battery was replaced.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2175
OMSA Trap ID
115100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*         ✔*

BAT1002

Message
The battery on arg1 learn cycle has started.
Arguments
  • arg1 = controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2176
OMSA Trap ID
115100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*         ✔*

BAT1003

Message
The battery on arg1 learn cycle has completed.
Arguments
  • arg1 = controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2177
OMSA Trap ID
115100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*         ✔*

BAT1004

Message
The battery on arg1 learn cycle has timed out.
Arguments
  • arg1 = controller name
Detailed Description
The controller battery must be fully charged before the learn cycle can begin. The battery may be unable to maintain a full charge causing the learn cycle to timeout. In addition, the battery must be able to maintain cached data for a specified period of time in the event of a power loss. For example, some batteries maintain cached data for 24 hours. If the battery is unable to maintain cached data for the required period of time, then the Learn cycle will timeout.
Recommended Response Action
Replace the battery pack. The battery is unable to maintain a full charge.
Category
Storage (BAT = Battery Event)
Severity
Severity 2 (Warning)
Trap/EventID
4274
OMSA Event ID
2178
OMSA Trap ID
115300
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC    
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*         ✔*

BAT1005

Message
The battery on arg1 learn cycle has been postponed.
Arguments
  • arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2179
OMSA Trap ID
115100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC              
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC   ✔*         ✔*

BAT1006

Message
The battery on arg1 learn cycle will start in arg2 days.
Arguments
  • arg1 = Controller name
  • arg2 = arg
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2180
OMSA Trap ID
115100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC              
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC   ✔*         ✔*

BAT1007

Message
The battery on arg1 learn cycle will start in arg2 hours.
Arguments
  • arg1 = Controller name
  • arg2 = arg
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2181
OMSA Trap ID
115100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC              
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC   ✔*         ✔*

BAT1008

Message
Write policy on arg1 was changed to Write Through.
Arguments
  • arg1 = controller name
Detailed Description
The controller battery cannot maintain cached data for the required period of time. For example, if the required period of time is 24 hours, then the battery cannot maintain cached data for 24 hours.
Recommended Response Action
Verify the battery health is good. See the storage hardware documentation to verify battery health. Contact technical support.
Category
Storage (BAT = Battery Event)
Severity
Severity 2 (Warning)
Trap/EventID
4274
OMSA Event ID
2188
OMSA Trap ID
115300
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*         ✔*

BAT1009

Message
Write policy on arg1 was changed to Write Back.
Arguments
  • arg1 = controller name
Detailed Description
The controller battery health has returned to normal.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2189
OMSA Trap ID
115100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*         ✔*

BAT1010

Message
Battery on arg1 requires reconditioning. Initiate a learn cycle.
Arguments
  • arg1 = Controller name
Detailed Description
Battery is in warn only mode and requires reconditioning.
Recommended Response Action
Start a learn cycle on the battery.
Category
Storage (BAT = Battery Event)
Severity
Severity 2 (Warning)
Trap/EventID
4274
OMSA Event ID
2210
OMSA Trap ID
115300
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC              
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC   ✔*         ✔*

BAT1011

Message
Battery on arg1 is in warn only mode and requires reconditioning.
Arguments
  • arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2104
OMSA Trap ID
115100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC              
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC   ✔*         ✔*

BAT1012

Message
The arg1 battery temperature is above normal.
Arguments
  • arg1 = Controller name
Detailed Description
Diagnostic event for service to determine if there is an ambient temperature problem.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC              
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC   ✔*         ✔*

BAT1013

Message
Recharge count has exceeded the maximum limit for battery on arg1 .
Arguments
  • arg1 = Controller name
Detailed Description
The battery cannot be recharged further.
Recommended Response Action
Replace the battery pack.
Category
Storage (BAT = Battery Event)
Severity
Severity 2 (Warning)
Trap/EventID
4274
OMSA Event ID
2213
OMSA Trap ID
115300
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC              
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC   ✔*         ✔*

BAT1014

Message
arg1 battery charge in-progress.
Arguments
  • arg1 = Controller name
Detailed Description
Diagnostic event for service to determine if there is an ambient temperature problem.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2214
OMSA Trap ID
115100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC              
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC   ✔*         ✔*

BAT1015

Message
arg1 battery charge process is interrupted.
Arguments
  • arg1 = Controller name
Detailed Description
Diagnostic event for service to determine if there is an ambient temperature problem.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2215
OMSA Trap ID
115100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC              
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC   ✔*        

BAT1016

Message
The arg1 battery learn mode has changed to Auto.
Arguments
  • arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2216
OMSA Trap ID
115100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC              
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC   ✔*        

BAT1017

Message
The arg1 battery learn mode has changed to Warn.
Arguments
  • arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2217
OMSA Trap ID
115100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC              
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC   ✔*        

BAT1018

Message
Battery on arg1 is degraded.
Arguments
  • arg1 = Controller name
Detailed Description
The temperature of the battery is high. This may be due to the battery being charged.
Recommended Response Action
If the battery is being charged, then charging the battery should be stopped until the battery cools down and charging should be resumed. If this is not case, then some other condition exists and should be investigated.
Category
Storage (BAT = Battery Event)
Severity
Severity 2 (Warning)
Trap/EventID
4274
OMSA Event ID
2246
OMSA Trap ID
115300
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC              
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC   ✔*        

BAT1019

Message
Battery on arg1 is charging.
Arguments
  • arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2247
OMSA Trap ID
115100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC              
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC   ✔*        

BAT1020

Message
The arg1 battery is executing a learn cycle.
Arguments
  • arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2248
OMSA Trap ID
115100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC    
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*        

BAT1021

Message
The charge level for the battery on arg1 is below the normal threshold.
Arguments
  • arg1 = controller name
Detailed Description
The controller battery cannot maintain sufficient charge level to function properly or the battery is discharging.
Recommended Response Action
Check for other events related to the state of the battery. These may help determine the cause of this event.
Category
Storage (BAT = Battery Event)
Severity
Severity 2 (Warning)
Trap/EventID
4274
OMSA Event ID
2278
OMSA Trap ID
115300
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*        

BAT1022

Message
arg1 battery recondition is completed.
Arguments
  • arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2105
OMSA Trap ID
115100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC              
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC   ✔*        

BAT1023

Message
The charge level for the battery on arg1 is within normal limits.
Arguments
  • arg1 = controller name
Detailed Description
The battery health has returned to normal.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2279
OMSA Trap ID
115100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*        

BAT1024

Message
Errors detected with battery on arg1 .
Arguments
  • arg1 = controller name
Detailed Description
The battery or the battery charger is not functioning properly. The battery may have an inadequate charge.
Recommended Response Action
Contact technical support.
Category
Storage (BAT = Battery Event)
Severity
Severity 2 (Warning)
Trap/EventID
4274
OMSA Event ID
2318
OMSA Trap ID
115300
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*        

BAT1025

Message
arg1 is unable to recover cached data from the Battery Backup Unit (BBU).
Arguments
  • arg1 = controller name
Detailed Description
The controller was unable to recover data from the cache. This may indicate data loss has occurred.
Recommended Response Action
Verify that the battery is charged and in good health. See the hardware documentation for more information. When the battery charge is unacceptably low, the battery cannot maintain cached data. Data loss may also have occurred, restoring data from backups may be needed. Verify whether the battery has met its recharge limit. The battery may need to be recharged. Contact technical support if the issue persists.
Category
Storage (BAT = Battery Event)
Severity
Severity 1 (Critical)
Trap/EventID
4273
OMSA Event ID
2337
OMSA Trap ID
115400
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*        

BAT1026

Message
The arg1 has recovered cached data from the Battery Backup Unit (BBU).
Arguments
  • arg1 = controller name
Detailed Description
The controller has retrieved cached data.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2338
OMSA Trap ID
115100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*        

BAT1027

Message
The battery on arg1 completed a charge cycle.
Arguments
  • arg1 = controller name
Detailed Description
The battery successfully completed a charge cycle.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2358
OMSA Trap ID
115100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*        

BAT1028

Message
The battery voltage on arg1 is low.
Arguments
  • arg1 = controller name
Detailed Description
The controller battery voltage is low. This may indicate that the battery is no longer protecting the controller cache.
Recommended Response Action
The battery needs to recharged. Wait 24 hours to see if the charge is restored.
Category
Storage (BAT = Battery Event)
Severity
Severity 2 (Warning)
Trap/EventID
4274
OMSA Event ID
2145
OMSA Trap ID
115300
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*        

BAT1029

Message
The battery on arg1 can no longer recharge.
Arguments
  • arg1 = controller name
Detailed Description
The controller battery cannot recharge. The battery may have already recharged the maximum number of times or the battery charger may not be working.
Recommended Response Action
Contact technical support.
Category
Storage (BAT = Battery Event)
Severity
Severity 1 (Critical)
Trap/EventID
4273
OMSA Event ID
2169
OMSA Trap ID
115400
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*        

BAT1030

Message
The arg1 battery charge level is normal.
Arguments
  • arg1 = Controller name
Detailed Description
This alert is provided for informational purposes.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2170
OMSA Trap ID
115100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC              
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*            
CMC   ✔*        

BAT1031

Message
The battery temperature on arg1 is above normal.
Arguments
  • arg1 = controller name
Detailed Description
The room temperature may be too hot. In addition, the system fan may be degraded or failed.
Recommended Response Action
Verify that the room temperature is normal and that fans are functioning properly. See the storage hardware documentation for acceptable operating temperatures.
Category
Storage (BAT = Battery Event)
Severity
Severity 2 (Warning)
Trap/EventID
4274
OMSA Event ID
2171
OMSA Trap ID
115300
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*        

BAT1032

Message
The battery temperature on arg1 is normal.
Arguments
  • arg1 = controller name
Detailed Description
The battery temperature is within the normal operating range.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
OMSA Event ID
2172
OMSA Trap ID
115100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*        

BAT1033

Message
The battery on arg1 was removed.
Arguments
  • arg1 = controller name
Detailed Description
The controller cannot communicate with the battery. Either the battery was removed, or the contact point between the controller and the battery is degraded.
Recommended Response Action
Make sure that the battery is present and properly connected. If the battery is present, wait for a few minutes and re-check if the battery is detected. If the contact point between the battery and the controller is degraded, you must replace the battery, the controller, or both. Refer to the storage hardware documentation for information on how to safely access, or remove. Contact technical support if the issue persists.
Category
Storage (BAT = Battery Event)
Severity
Severity 2 (Warning)
Trap/EventID
4274
OMSA Event ID
2174
OMSA Trap ID
115300
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*        

BAT1034

Message
The battery properties for arg1 have changed.
Arguments
  • arg1 = controller name
Detailed Description
One or more battery properties were modified.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC   ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*        

BAT1035

Message
The battery temperature on arg1 is above the normal operating temperature.
Arguments
  • arg1 = controller name
Detailed Description
The battery temperature is above normal operating temperature.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
OMSA Event ID
2212;2415
OMSA Trap ID
115100
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC      
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC          
CMC              

BAT1036

Message
The battery on arg1 is discharging.
Arguments
  • arg1 = controller name
Detailed Description
The battery on the controller identified in the message is being discharged.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC      
CMC              
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC          
CMC              

BAT1037

Message
A battery is detected on the Controller arg1 .
Arguments
  • arg1 = controller name
Detailed Description
A battery is detected on the Controller identified in the message.
Recommended Response Action
No response action is required.
Category
Storage (BAT = Battery Event)
Severity
Severity 3 (Informational)
Trap/EventID
4275
Redfish Event Type
Alert
  Filter Visibility IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing Redfish Eventing
iDRAC  
CMC     ✔* ✔* ✔*    
  LC Log LCD OS Log Power Off Power Cycle Reset Chassis Event Proxy
iDRAC ✔*          
CMC   ✔*         ✔*

본 콘텐츠를 평가해주십시오.

정확함
유용함
이해하기 쉬운
이 문서가 도움이 되셨나요?
0/3000 characters
  평점(별 1~5개)을 매겨주십시오.
  평점(별 1~5개)을 매겨주십시오.
  평점(별 1~5개)을 매겨주십시오.
  문서가 도움이 되었는지 여부를 선택하십시오.
  의견에는 <>()\와 같은 특수 문자를 사용할 수 없습니다.