メイン コンテンツに進む
  • すばやく簡単にご注文が可能
  • 注文内容の表示、配送状況をトラック
  • 会員限定の特典や割引のご利用
  • 製品リストの作成とアクセスが可能

Dell EMC SmartFabric OS10 User Guide Release 10.5.1

PDF

show vfabric

Shows the fc timer, E_D_TOV, R_A_TOV, principal switch priority, and domain ID values in the show vfabric command.

Syntax
show vfabric value
Parameters

value—Valid values are from 1 to 255.

Defaults
Not applicable
Command Mode
GLOBAL CONFIGURATION
Usage Information

Use this command to display the fc timers, E_D_TOVand R_A_TOV, principal switch priority and domain ID values. Also, this command shows the configured domain ID, run-time domain ID, and the principal switch priority of the switch.

Example
OS10# show vfabric
Fabric Name SAN_FABRIC
Fabric Type Multi-Switch
Fabric Id 10
VlanId 1002
FC-MAP 0xEFC00
FCF Priority 128
FKA-Adv-Period Enabled, 8
Config-State ACTIVE
Oper-State UP
=================================================
Switch Config Parameters
==================================================
Domain ID 3
Switch Priority 3
E-D-TOV(ms) 1000
R-A-TOV(ms) 5000
==================================================
Switch Fabric Parameters
==================================================
Run Time Domain ID 4
Run Time Switch Priority 3
==================================================
Switch Zoning Parameters
=================================================
Default Zone Mode: Deny
Active ZoneSet: zoneset5
==========================================
Members
fibrechannel1/1/11
fibrechannel1/1/17
fibrechannel1/1/22
Supported Releases