Enabling or Disabling vFlash Functionality Using RACADM

To enable or disable the vFlash functionality using RACADM, use one of the following:
  • Using config command:
    • To enable vFlash:

      racadm config -g cfgvFlashsd -o cfgvflashSDEnable 1

    • To disable vFlash:

      racadm config -g cfgvFlashsd -o cfgvflashSDEnable 0

  • Using set command:
    • To enable vFlash:

      racadm set iDRAC.vflashsd.Enable 1

    • To disable vFlash:

      racadm set iDRAC.vflashsd.Enable 0

  • NOTE: The RACADM command functions only if a vFlash SD card is present. If a card is not present, the following message is displayed: ERROR: SD Card not present .