Dell OpenManage Server Administrator Version 7.4 Command Line Interface Guide

Omreport Chassis Acswitch Or Omreport Mainsystem Acswitch

Use the omreport chassis acswitch or omreport mainsystem acswitch command if the system has redundant AC power lines that are configured in a failover arrangement. Type:
omreport chassis acswitch
or
omreport mainsystem acswitch
Server Administrator displays the following output:
AC Failover Switch  
AC Switch Redundancy  
   
Redundancy Status : Full
Number of devices required for full redundancy : 2
Redundancy Mode :
Redundancy Configuration : Input Source Line 1, upon redundancy restoration, return to Line 1
AC Power Lines
Status : Ok
Location : AC Power Line 1
AC Present : Power Present
Active Source : Active
Status : Ok
Location : AC Power Line 2
AC Present : Power Present
Active Source : Not Active

Server Administrator reports values for the Redundancy Status and Redundancy Mode fields.