Passa al contenuto principale
  • Effettua gli ordini in modo rapido e semplice
  • Visualizza gli ordini e monitora lo stato della spedizione
  • Crea e accedi a un elenco dei tuoi prodotti

Dell OpenManage Server Administrator Version 7.4 Command Line Interface Guide

Omconfig Unblink Physical Disk

Description

Unblinks the light (light emitting diode or LED display) on one or more physical disks attached to a controller.

Syntax

omconfig storage pdisk action=unblink controller=id pdisk=< PDISKID> , where id is the controller ID. The <PDISKID> variable specifies the physical disk.
  • NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.

Example to

Unblink physical disk 0 on connector 0 of controller 1. On a SAS controller, the physical disk resides in enclosure 2.

Example for SCSI, SATA, and ATA controllers

omconfig storage pdisk action=unblink controller=1 pdisk=0:0

Example for SAS controllers

omconfig storage pdisk action=unblink controller=1 pdisk=0:2:0


Classifica questo contenuto

Preciso
Utile
Facile da comprendere
Questo articolo ti è stato d'aiuto?
0/3000 characters
  Fornisci una valutazione (1-5 stelle).
  Fornisci una valutazione (1-5 stelle).
  Fornisci una valutazione (1-5 stelle).
  Indica se l'articolo è stato utile o meno.
  I commenti non possono contenere i seguenti caratteri speciali: <>() \