Dell OpenManage Server Administrator Version 7.4 Command Line Interface Guide

Omconfig Reset Temperature Probe Thresholds

Table 1. Omconfig Reset Temperature Probe Thresholds

Description

Resets the minimum and maximum warning temperature thresholds back to their default values.
  • NOTE: This command is not supported on SAS controllers.

Syntax

omconfig storage enclosure action=resettempprobes controller=id enclosure=< ENCLOSUREID> index=id , where id is the controller ID and the temperature probe ID. The <ENCLOSUREID> variable specifies the enclosure.

In this syntax, n is a user-specified alphanumeric string.

Example to

Reset the thresholds for temperature probe 3, residing in the enclosure attached to connector 2 on controller 1, to the default values.

Example for SCSI, SATA, and ATA controllers

omconfig storage enclosure action=resettempprobes controller=1 enclosure=2 index=3