Passer au contenu principal
  • Passer des commandes rapidement et facilement
  • Afficher les commandes et suivre l’état de votre expédition
  • Créez et accédez à une liste de vos produits

Integrated Dell Remote Access Controller 9 User's Guide

Setting event alerts using web interface

To set an event alert using the web interface:
  1. Make sure that you have configured the e-mail alert, IPMI alert, SNMP trap settings, and/or remote system log settings.
  2. In iDRAC Web interface, go to Configuration > System Settings > Alerts and Remote System Log Configuration.
  3. Under Category, select one or all of the following alerts for the required events:
    • Email
    • SNMP Trap
    • IPMI Alert
    • Remote System Log
    • WS Eventing
    • OS Log
    • Redfish Event
  4. Select Action.
    The setting is saved.
  5. Optionally, you can send a test event. In the Message ID to Test Event field, enter the message ID to test if the alert is generated and click Test. For more information about the event and error messages generated by the system firmware and agents that monitor system components, see the Event and Error Message Reference Guide at iDRACmanuals