Integrated Dell Remote Access Controller 9 User's Guide

Configuring warning threshold for inlet temperature using web interface

To configure warning threshold for inlet temperature:
  1. In the iDRAC Web interface, go to System > Overview > Cooling > Temperature overview.
    The Temperature overview page is displayed.
  2. In the Temperature Probes section, for the System Board Inlet Temp, enter the minimum and maximum values for the Warning Threshold in Centigrade or Fahrenheit. If you enter the value in centigrade, the system automatically calculates and displays the Fahrenheit value. Similarly, if you enter Fahrenheit, the value for Centigrade is displayed.
  3. Click Apply.
    The values are configured.
    NOTE Changes to default thresholds are not reflected in the historical data chart since the chart limits are for fresh air limit values only. Warnings for exceeding the custom thresholds are different from warning associated to exceeding fresh air thresholds.