Dell-Current sensor detected a warning value |
A current sensor in the specified system exceeded
its warning threshold |
Warning |
No action |
Dell-Current sensor detected a failure value |
A current sensor in the specified system exceeded
its failure threshold |
Error |
Put the system into maintenance mode |
Dell-Current sensor detected a non-recoverable
value |
A current sensor in the specified system detected
an error from which it cannot recover |
Error |
No action |
Dell-Redundancy regained |
Sensor Returned to Normal Value |
Info |
No action |
Dell-Redundancy degraded |
A redundancy sensor in the specified system detected
that one of the components of the redundancy unit has failed but the
unit is still redundant |
Warning |
No action |
Dell-Redundancy lost |
A redundancy sensor in the specified system detected
that one of the components in the redundant unit has been disconnected,
has failed, or is not present |
Error |
Put the system into maintenance mode |
Dell-Power supply returned to normal |
Sensor returned to Normal Value |
Info |
No action |
Dell-Power supply detected a warning |
A power supply sensor reading in the specified
system exceeded a user definable warning threshold |
Warning |
No action |
Dell-Power supply detected a failure |
A power supply has been disconnected or has failed |
Error |
Put the system into maintenance mode |
Dell-Power supply sensor detected a non-recoverable
value |
A power supply sensor in the specified system detected
an error from which it cannot recover |
Error |
No action |
Dell-Memory Device Status warning |
A memory device correction rate exceeded an acceptable
value |
Warning |
No action |
Dell-Memory Device error |
A memory device correction rate exceeded an acceptable
value, a memory spare bank was activated, or a multibit ECC error
occurred |
Error |
Put the system into maintenance mode |
Dell-Fan enclosure inserted into system |
Sensor returned to normal value |
Info |
No action |
Dell-Fan enclosure removed from system |
A fan enclosure has been removed from the specified
system |
Warning |
No action |
Dell-Fan enclosure removed from system for an
extended amount of time |
A fan enclosure has been removed from the specified
system for a user-definable length of time |
Error |
No action |
Dell-Fan enclosure sensor detected a non-recoverable
value |
A fan enclosure sensor in the specified system
detected an error from which it cannot recover |
Error |
No action |
Dell-AC power has been restored |
Sensor Returned to Normal Value |
Info |
No action |
Dell-AC power has been lost warning |
An AC power cord has lost its power, but there
is sufficient redundancy to classify this as a warning |
Warning |
No action |
Dell-An AC power cord has lost its power |
An AC power cord has lost its power, and lack
of redundancy requires this to be classified as an error |
Error |
No action |
Dell-Processor sensor returned to a normal value |
Sensor Returned to Normal Value |
Info |
No action |
Dell-Processor sensor detected a warning value |
A processor sensor in the specified system is in
a throttled state |
Warning |
No action |
Dell-Processor sensor detected a failure value |
A processor sensor in the specified system is
disabled, has a configuration error, or experienced a thermal trip |
Error |
No action |
Dell-Processor sensor detected a non-recoverable
value |
A processor sensor in the specified system has
failed. |
Error |
No action |
Dell-Device configuration error |
A configuration error was detected for a pluggable
device in the specified system |
Error |
No action |
Dell-Battery sensor returned to a normal value |
Sensor Returned to Normal Value |
Info |
No action |
Dell-Battery sensor detected a warning value |
A battery sensor in the specified system detected
that a battery is in a predictive failure state |
Warning |
No action |
Dell-Battery sensor detected a failure value |
A battery sensor in the specified system detected
that a battery has failed |
Error |
No action |
Dell-Battery sensor detected a nonrecoverable value |
A battery sensor in the specified system detected
that a battery has failed |
Error |
No Action |
Dell-Thermal shutdown protection has been initiated |
This message is generated when a system is configured
for thermal shutdown due to an error event. If a temperature sensor
reading exceeds the error threshold for which the system is configured,
the operating system shuts down and the system powers off. This event
may also be initiated on certain systems when a fan enclosure is removed
from the system for an extended period of time |
Error |
No action |
Dell-Temperature sensor returned to a normal value |
Sensor Returned to Normal Value |
Info |
No action |
Dell-Temperature sensor detected a warning value |
A temperature sensor on the backplane board, system
board, CPU, or drive carrier in the specified system exceeded its
warning threshold |
Warning |
No action |
Dell-Temperature sensor detected a failure value |
A temperature sensor on the backplane board, system
board, or drive carrier in the specified system exceeded its failure
threshold value |
Error |
Put the system into maintenance mode |
Dell-Temperature sensor detected a non-recoverable
value |
A temperature sensor on the backplane board, system
board, or drive carrier in the specified system detected an error
from which it cannot recover |
Error |
No action |
Dell-Fan sensor returned to a normal value |
Sensor Returned to Normal Value |
Info |
No action |
Dell-Fan sensor detected a warning value |
Fan Sensor reading in the host <x> exceeded
a warning threshold value |
Warning |
No Action |
Dell-Fan sensor detected a failure value |
A fan sensor in the specified system detected
the failure of one or more fans |
Error |
Put the system into maintenance mode |
Dell-Fan sensor detected a nonrecoverable value |
A fan sensor detected an error from which it cannot
recover |
Error |
No action |
Dell-Voltage sensor returned to a normal value |
Sensor Returned to Normal Value |
Info |
No action |
Dell-Voltage sensor detected a warning value |
A voltage sensor in the specified system exceeded
its warning threshold |
Warning |
No action |
Dell-Voltage sensor detected a failure value |
A voltage sensor in the specified system exceeded
its failure threshold |
Error |
Put the system into maintenance mode |
Dell-Voltage sensor detected a nonrecoverable
value |
A voltage sensor in the specified system detected
an error from which it cannot recover |
Error |
No action |
Dell-Current sensor returned to a normal value |
Sensor Returned to Normal Value |
Info |
No action |
Dell-Storage: storage management error |
Storage management has detected a device independent
error condition |
Error |
Put the system into maintenance mode |
Dell-Storage: Controller warning |
A portion of the physical disk is damaged |
Warning |
No action |
Dell-Storage: Controller failure |
A portion of the physical disk is damaged |
Error |
Put the system into maintenance mode |
Dell-Storage: Channel Failure |
Channel failure |
Error |
Put the system into maintenance mode |
Dell-Storage: Enclosure hardware information |
Enclosure hardware information |
Info |
No action |
Dell-Storage: Enclosure hardware warning |
Enclosure hardware warning |
Warning |
No action |
Dell-Storage: Enclosure hardware failure |
Enclosure hardware error |
Error |
Put the system into maintenance mode |
Dell-Storage: Array disk failure |
Array disk failure |
Error |
Put the system into maintenance mode |
Dell-Storage: EMM failure |
EMM failure |
Error |
Put the system into maintenance mode |
Dell-Storage: power supply failure |
Power supply failure |
Error |
Put the system into maintenance mode |
Dell-Storage: temperature probe warning |
Physical disk temperature probe warning, too cold
or too hot |
Warning |
No action |
Dell-Storage: temperature probe failure |
Physical disk temperature probe error, too cold
or too hot. |
Error |
Put the system into maintenance mode |
Dell-Storage: Fan failure |
Fan failure |
Error |
Put the system into maintenance mode |
Dell-Storage: Battery warning |
Battery warning |
Warning |
No action |
Dell-Storage: Virtual disk degraded warning |
Virtual disk degraded warning |
Warning |
No action |
Dell-Storage: Virtual disk degraded failure |
Virtual disk degraded failure |
Error |
Put the system into maintenance mode |
Dell-Storage: Temperature probe information |
Temperature probe information |
Info |
No action |
Dell-Storage: Array disk warning |
Array disk warning |
Warning |
No action |
Dell-Storage: Array disk information |
Array disk information |
Info |
No action |
Dell-Storage: Power supply warning |
Power supply warning |
Warning |
No action |
Dell-Fluid Cache Disk failure |
Fluid cache disk failure |
Error |
Put the system into maintenance mode |
Dell-Cable failure or critical event |
Cable failure or critical event |
Error |
Put the system into maintenance mode |
Dell-Chassis Management Controller detected a
warning |
Chassis Management Controller detected a warning |
Warning |
No action |
Dell-Chassis Management Controller detected an
error |
Chassis Management Controller detected an error |
Error |
Put the system into maintenance mode |
Dell-IO Virtualization failure or critical event |
IO virtualization failure or critical event |
Error |
Put the system into maintenance mode |
Dell-Link status warning |
Link status warning |
Warning |
No action |
Dell-Link status failure or critical event |
Link status failure or critical event |
Error |
Put the system into maintenance mode |
Dell-Security warning |
Security warning |
Warning |
No action |
Dell-System: Software configuration warning |
System: Software configuration warning |
Warning |
No action |
Dell-System: Software configuration failure |
System: Software configuration failure |
Error |
Put the system into maintenance mode |
Dell-Storage Security warning |
Storage security warning |
Warning |
No action |
Dell-Storage Security failure or critical event |
Storage security failure or critical event |
Error |
Put the system into maintenance mode |
Dell-Software change update warning |
Software change update warning |
Warning |
No action |
Dell-Chassis Management Controller audit warning |
Chassis Management Controller audit warning |
Warning |
No action |
Dell-Chassis Management Controller audit failure
or critical event |
Chassis Management Controller audit failure or
critical event |
Error |
Put the system into maintenance mode |
Dell-PCI device audit warning |
PCI device audit warning |
Warning |
No action |
Dell Power Supply audit warning |
Power supply audit warning |
Warning |
No action |
Dell-Power Supply audit failure or critical event |
Power supply audit failure or critical event |
Error |
Put the system into maintenance mode |
Dell-Power usage audit warning |
Power usage audit warning |
Warning |
No action |
Dell-Power usage audit failure or critical event |
Power usage audit failure or critical event |
Error |
Put the system into maintenance mode |
Dell-Security configuration warning |
Security configuration warning |
Warning |
No action |
Dell-Configuration: Software configuration warning |
Configuration: Software configuration warning |
Warning |
No action |
Dell-Configuration: Software configuration failure |
Configuration: Software configuration failure |
Error |
Put the system into maintenance mode |
Dell-Virtual Disk Partition failure |
Virtual disk partition failure |
Error |
Put the system into maintenance mode |
Dell-Virtual Disk Partition warning |
Virtual disk partition warning |
Warning |
No action |
iDRAC events NOTE: For all Proactive HA enabled hosts that are part of a cluster, the following virtualization events are mapped to the Proactive HA events; except events, "The fans are not redundant" and "The power supplies are not redundant" are not mapped. |
The fans are redundant |
None |
Info |
No action |
Fan redundancy is lost |
One of more fans have failed or have been removed
or a configuration change occurred, which requires additional fans |
Critical |
Remove and reinstall failed fans or install additional
fans |
Fan redundancy is degraded |
One of more fans have failed or have been removed or a configuration change occurred, which requires additional fans. |
Warning |
Remove and reinstall failed fans or install additional fans |
The fans are not redundant | One of more fans have failed or have been removed or a configuration change occurred, which requires additional fans | Info | Remove and reinstall failed fans or install additional fans |
The fans are not redundant. Insufficient resources to maintain normal operations | One of more fans have failed or have been removed or a configuration change occurred, which requires additional fans | Critical | Remove and reinstall failed fans or install additional fans |
The power supplies are redundant | None | Info | No action |
Power supply redundancy is lost | The current power operational mode is non-redundant because of a power supply exception, a power supply inventory change, or a system power inventory change. The system was previously operating in a power redundant mode | Critical | Check the event log for power supply failures. Review system configuration and power consumption |
Power supply redundancy is degraded | The current power operational mode is non-redundant because of a power supply exception, a power supply inventory change, or a system power inventory change. The system was previously operating in a power redundant mode | Warning | Check the event log for power supply failures. Review system configuration and power consumption |
The power supplies are not redundant | The current power supply configuration does not meet the platform requirements to enable redundancy. If a power supply fails the system may shut down. | Info | If unintended, review system configuration and power consumption and install power supplies accordingly. Check power supply status for failures |
The power supplies are not redundant. Insufficient resources to maintain normal operations | The system may power down or operate in a performance degraded state | Critical | Check the event log for power supply failures. Review system configuration and power consumption and upgrade or install power supplies accordingly |
Internal Dual SD Module is redundant | None | Info | No action |
Internal Dual SD Module redundancy is lost | Either one of the SD card or both the SD cards are not functioning properly | Critical | Replace the failed SD card |
Internal Dual SD Module redundancy is degraded | Either one of the SD card or both the SD cards are not functioning properly | Warning | Replace the failed SD card |
Internal Dual SD Module is not redundant | None | Info | Install additional SD card and configure for redundancy if redundancy is desired |
Chassis events |
Power supply redundancy is lost | The current power operational mode is non-redundant because of a power supply exception, a power supply inventory change, or a system power inventory change. The system was previously operating in a power redundant mode | Critical | Check the event log for power supply failures. Review system configuration and power consumption |
Power supply redundancy is degraded | The current power operational mode is non-redundant because of a power supply exception, a power supply inventory change, or a system power inventory change. The system was previously operating in a power redundant mode | Warning | Check the event log for power supply failures. Review system configuration and power consumption |
The power supplies are redundant | None | Info | No action |
The power supplies are not redundant | The current power supply configuration does not meet the platform requirements to enable redundancy. If a power supply fails the system may shut down. | Info | If unintended, review system configuration and power consumption and install power supplies accordingly. Check power supply status for failures |
The power supplies are not redundant. Insufficient resources to maintain normal operations | The system may power down or operate in a performance degraded state | Critical | Check the event log for power supply failures. Review system configuration and power consumption and upgrade or install power supplies accordingly |
Fan redundancy is lost | One of more fans have failed or have been removed
or a configuration change occurred, which requires additional fans | Critical | Remove and reinstall failed fans or install additional
fans |
Fan redundancy is degraded | One of more fans have failed or have been removed or a configuration change occurred, which requires additional fans. | Warning | Remove and reinstall failed fans or install additional fans |
The fans are redundant | None | Info | No action |
The fans are not redundant | One of more fans have failed or have been removed or a configuration change occurred, which requires additional fans | Info | Remove and reinstall failed fans or install additional fans |
The fans are not redundant. Insufficient resources to maintain normal operations | One of more fans have failed or have been removed or a configuration change occurred, which requires additional fans | Critical | Remove and reinstall failed fans or install additional fans |