Physical Disks | ||
---|---|---|
Physical disks | Up to sixty 3.5 inch or 2.5 inch SAS or nearline SAS physical disks or 2.5 inch SAS SSDs |
Enclosure Management Modules | |||
---|---|---|---|
Dell PowerVault MD3060e storage enclosures | Supports 60 physical disks
Redundant path connectivity provides redundant data paths to each hard drive |
||
SAS connectors | Two SAS ports (marked IN)
to connect to host server(s) or to expand the MD series storage dense
enclosure
Third SAS port labelled OUT. Port can be used for further storage enclosure expansion or storage enclosure fault tolerance. |
||
Serial connector (debug port) | Six pin port |
Power | ||
---|---|---|
AC power supply (per power supply) | ||
Wattage | 1755 W | |
Heat dissipation (maximum) | 5988 BTU/hr | |
Voltage | 220 V AC, autoranging, 50 Hz/60 Hz |
Environmental | ||
---|---|---|
Temperature | ||
Operating | Continuous operation: 10 °C to 35 °C (50 °F to 95 °F) at 20% to 80% relative humidity (RH), with 26 °C maximum dew point. De-rate maximum allowable dry bulb temperature at 1 °C/300 m (1 °F per 550 ft) above 900 m (2952.75 ft). | |
Storage | –40 °C to 65 °C (–40 °F to 149 °F) with a maximum temperature gradation of 20 °C per hour | |
Relative humidity | ||
Operating | 20% to 80% (noncondensing) with maximum humidity gradation of 10% per hour | |
Storage | 5% to 95% at a maximum wet bulb temperature of 38 °C (100.4 °F) | |
Maximum vibration | ||
Operating | 0.26 G rms at 5 Hz to 350 Hz in operational orientation | |
Storage | 1.88 G rms at 10 Hz to 500 Hz for 15 minutes (all six sides tested) | |
Maximum shock | ||
Operating |
One shock pulse in the positive z axis of the system at 31 G for 2.6 ms in the operational orientation |
|
Storage | Six consecutively executed
shock pulses in the positive and negative x, y, and z axes (one pulse
on each side of the system) at 71 G for up to 2 ms
Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 22 G faired square wave pulse with velocity change at 200 inches/second (508 centimeters/second) |
|
Altitude | ||
Operating | Maximum 3000 m (9,842 ft) | |
Storage | Maximum 12192 m (40,000 ft) | |
Airborne contaminant level | ||
Class | G1 as defined by ISA-S71.04-1985 |