Dell EMC PowerEdge R540 Installation and Service Manual

Removing the cooling fan

The procedure for removing standard and high performance fans are identical.

Prerequisites

  1. Follow the safety guidelines listed in Safety instructions.
  2. Follow the procedure listed in Before working inside your system.
  3. Removing the air shroud
  4. Removing the internal PERC riser
  5. Move the cables out of the way to access the cooling fan cable connector on the system board.

Steps

  1. Lift the fan out holding the blue touch point.
  2. Disconnect the cooling fan cable connected to the system board connector.
    NOTE In the 12 x 3.5-inch drive system, disconnect the fan 1 cable from the power interposer board connector.
    Figure 1. Disconnecting fan cable from PIB connector
    This images shows disconnecting fan cable from PIB connector
  3. Press the release tab and lift the cooling fan out of the cooling fan cage.
    Figure 2. Removing cooling fan
    The image shows removing cooling fan