Dell EMC PowerEdge R540 Installation and Service Manual

Installing cooling fan

The procedure for installing standard and high performance fans are identical.

Prerequisites

  1. Follow the safety guidelines listed in Safety instructions.
  2. Follow the procedure listed in Before working inside your system.
  3. Removing the air shroud
  4. Removing the internal PERC riser
  5. Remove the power cable.
  6. Move the cables out of the way to access the cooling fan cable connector on the system board.

Steps

  1. Holding the release tab blue touch point, place the cooling fan into the cooling fan cage.
  2. Route the cooling fan cable and connect it to the connector on the system board.
    Figure 1. Installing cooling fan
    This image shows installing cooling fan
    NOTE In the 12 x 3.5-inch drive system, connect the fan 1 cable to the power interposer board connector.
    Figure 2. Connecting fan cable to PIB connector
    This image shows connecting fan cable to PIB connector

Next steps

  1. Installing the internal PERC riser
  2. Ensure all the cables are routed correctly.
  3. Installing the air shroud
  4. Follow the procedure listed in After working inside your system.