Option |
Description |
Alternate=[no, yes] |
Default is no. Yes/no option
to use an alternate IP address returned from an ICA master browser
to get through firewalls. |
AudioQualityMode={0, 1, 2, 3} |
Default is 0. Specifies the
audio quality of a session. 0 – Default 1 – High Quality 2 – Medium Quality 3 – Low Quality |
Autoconnect={0 to 99} |
Default is 0. Use for automatically starting a session after you sign
in, if sign-on is enabled. The value of 0 – 99 is
the delay in seconds before auto-starting the session. |
AppendUsername=1 |
This enhancement allows user names
to display in the title bar of an ICA session at the client side. |
Browserip=list of browsers |
List of IP addresses or DNS registered
names to specify ICA browsers. List items must be separated by semicolons
or commas. |
Colors={256, 32k, 64k or high, 16m, true} |
Default is high. Session
color mode. For faster display performance, use 256 colors for the
session.
- 256 is 8-bits
32k is 15-bits
64k or high is 16-bits
16m is 24-bits
true is 32-bits
NOTE:
- 64k is the same value as high.
16m — 24-bits over ICA is only supported
by Windows XP and Windows 2003 server. It is not supported by Windows
Server 2008 or newer.
true — 32-bit remote connections are
not supported by Windows XP or Windows 2003 server. It requires Windows
Vista, Windows Server 2008, or newer with ICA.
|
Command=start command |
A string of commands to be executed
after logging on to the server. This entry is limited to 127 characters. |
Description=string description |
Connection description. Enclose
the string description in quotation marks if there are embedded blanks
or single quotes. For quotation marks, use common-practice nesting
rules. Maximum of 38 characters are allowed. |
Directory=working directory |
A directory to be used as the
working directory after logging on to the server. Maximum of 63 characters
are allowed. |
Disablesound={no, yes, 2}
or {0, 1, 2} |
Default is no. Specifies whether or not to disable remote sound upon
connection start. |
Domainname={domain name,$DN} |
Domain name to use in a Windows
network. $DN specifies that the thin client sign-on domain name is
used. Maximum of 19 characters are allowed. |
Encryption={None, Basic,
40, 56, 128, Login-128} |
Default is Basic. Connection security encryption level. The highest level
is 128-bit security (Login-128 option is 128 bit encryption for login
only).The lowest is None. NOTE:The
server must support the specified level of encryption or the connection
will fail. |
Fullscreen={no, yes} |
Default is no. Yes/no option to run the session in full screen. If Fullscreen=no
then the session runs in a windowed screen. |
Host=[name, IP, $SYS VAR] or Application=published application |
Host — A list of server
hostnames or IP addresses to which the thin client will attempt to
connect. The next server on the list is attempted if the previous
one failed. List items must be separated by semicolons or commas. NOTE:$UN (see System Variables) specifies that the sign-on user name is
used and should be set in a {username}.ini file. If set to Host=$UN
in a {username}.ini file, the hostname will display as the sign-on
user name. If set to Host=$UN in a wnos.ini file, the hostname will
display as the default start. Application — Defines the published application to launch. Application is required
if no host is specified. |
HttpBrowsing={no, yes} |
Default is no. Yes/no option to select an http browsing protocol. Use
HttpBrowsing=no for User Datagram Protocol (UDP). |
Icon={default, bitmap file} |
Specifies an icon to appear on
the thin client desktop for a connection. Use Icon=default to display
a system default icon for a connection. To use
an icon other than the default icon, enter the name with extension
of the bitmap file; ensure that the file is located in the FTP server
wnos\bitmap directory. If Icon= is not specified and the icon is not
specified by a PNAgent/PNLite server, no icon is displayed for a connection. |
KeepAlive={0 to 127} |
Specifies the number of minutes
to keep a session connected after the session is inactive. During
this period, one dummy packet will be sent to the server if network
traffic is lost. Default is 10. |
LocalCopy={no, yes} |
Default is no. Yes/no option to save the connection to the local NVRAM. The connection description of the Description option
is used as the index key into the local connection table. If a match
is found, then the entry is updated. Otherwise, a new entry is created. Maximum total of local entries is 16. |
Logon_mode={local-user,
smartcard, user-specified} |
Default is local-user. Specifies how users authenticate to the selected
application set or ICA connection. |
Lowband={no, yes} |
Default is no. Yes/no option to enable optimization for low speed connections
such as reducing audio quality and/or decreasing protocol-specific
cache size. |
Mapdisks={no, yes} |
Default is no. Yes/no option to auto-connect and map any connected USB
flash drive upon connection start. |
Mapdisksunderz |
NOTE:: DISCONTINUED. DO NOT USE . |
[NO_FontSmoothing={no, yes}] |
Default is no—font smoothing
is enabled by default. Yes/no option to disable
font smoothing. If set to yes, the font smoothing is disabled. |
NoReducer={no, yes} |
Default is no. Yes/no option to turn off compression. Default is no,
which enables compression. To turn off compression, enter yes. Used here is an option of the Connect statement.
It sets the value of NoReducer only for this specified connection. NOTE:By default the ICA protocol compresses the data to minimize the amount
of data that needs to traverse the network. This compression can be
as much as 50 percent for text-based applications such as Microsoft
Word and 40 percent less for graphics applications than the data streams
that are not compressed. |
Password={password, $SYS_VAR} |
Password to log-in to the application
server. Either a conventional login password or a variable can be
used. Maximum of 19 characters are allowed. The
value of password is a conventional login password. The value of $SYS_VAR is a system variable found in Table: System
variables. NOTE:The application server password is
not encrypted; it is strongly recommended not to specify it. The user
will be prompted to enter the password when the connection is made.
This application server password directive never starts a line, so
it can be distinguished from the thin client user sign-on password
which does starts a line. NOTE:The
Password option is not written into a {username}.ini file by a user.
When the New Password check box is selected, the system writes
the new, changed password into the {username}.ini file with encryption.
This password is then checked against the sign-on password with encryption
to determine whether sign-on is successful. |
Password-enc=an encrypted password |
Specifies an encrypted string as a password for
a connection. |
Reconnect={no, yes, 1 to
3600 (seconds)} |
Default is no. Controls automatic reconnection to an application after
a server disconnection. yes — Use to restart the
connection; the default delay time for yes reconnect is 20 seconds. no — Use to prevent reconnection after a disconnect. 1 to 3600 — Use an integer value of 1 to 3600 seconds
to restart the connection after the delay you want. For example, use
50 and the automatic reconnection to an application will occur after
50 seconds. |
Resolution=[default, Seamless,
<monitor resolution>] |
Default is default. Specifies the connection display resolution. default — Starts the connection using the current desktop
display setting with no window frame and border. Seamless — Available for use if the connection is to a published
application. For Seamless connections, the MetaFrame hosts select
the best-fit connection window for applications. <monitor resolution> — Resolution values you can use in the form
X x Y depending on your client. Example for monitor resolution: 1024
x 768. See the Release Notes of your client. |
SessionReliability={no, yes} |
Default is no. Yes/no option to enable session reliability. NOTE:ThinOS
thin clients do not support UDP browsing to obtain a new configuration
about session reliability on the server. The thin client always connects
to the default port. |
UniSession={no, yes} |
Default is no. Yes/no option to use a unisession. The connection will
launch only once at a time. |
UnmapClipboard={no, yes} |
Default is no. Yes/no option to disable clipboard redirection for an
ICA session if redirecting the clipboard. |
UnmapPrinters={no, yes} |
Default is no. Yes/no option to not auto-connect to local printers when
the connection starts. |
UnmapSerials={no, yes} |
Default is no. Yes/no option to not auto-connect to local serials when
the connection starts. |
UnmapUSB={no, yes} |
Default is no. Yes/no option to not auto-connect to local USB devices
(Virtual USB) when the connection starts. |
Username=[username, $SYS_VAR] |
Username to log-in to the application
server. Either a conventional login username or a variable can be
used. Maximum of 31 characters are allowed. The
value of username is a conventional login username. The value of $SYS_VAR is a system variable found in System variables. NOTE:The
combination of all the variables such as $IP@$DN are also supported. |
Username-enc=an encrypted username |
Specifies an encrypted string as a username for
a connection. |
[WyseVDA={no, yes}] |
Default is no. Yes/no option to enable Wyse Virtual Desktop Accelerator
for all ICA sessions. |