Third-generation Intel Xeon Scalable processors with up to 40 cores
Two
PSU specifications
The XC Core XC750 supports up to two AC or DC power supply units (PSUs).
WARNING: Instructions for the qualified electricians only:
System using -(48-60) V DC or 240 V DC power supplies are intended for restricted access locations. See Articles 110-5, 110-6, 110-11, 110-14, and 110-17 of the National Electrical Code, American National Standards Institute (ANSI)/National Fire Protection Association (NFPA) 70.
If applicable in the country or region of use, 240 V DC power supplies shall be connected to the 240 V DC outlet from certified power distribution units.
Power supply cords and jumper cords and the associated plugs, inlets, and connectors shall have appropriate electrical ratings. The rating shall reference the rating label on the system when used for connection.
Table 4. PSU specificationsPSU specifications.
PSU
Class
Heat dissipation (maximum BTU/hr)
Frequency
(Hz)
Voltage
AC
Current
High line 200–240 V
Low line 100–120 V
Peak Power
-
Peak Power
-
-72 VDC
-72 VDC
240 VDC
-40 VDC
40 VDC
800 W AC
Platinum
3139
50/60
100–240 V
1360 W
800 W
800 W
1360 W
800 W
9.2 - 4.7 A
800 W
Mixed mode
N/A
3139
N/A
240 V
3.8 A
1100 W
AC
Titanium
4299
50/60 Hz
100-240 V
1870 W
1100 W
1100 W
1785 W
1050 W
12 - 6.3 A
1100 W
Mixed mode
N/A
4299
N/A
240 VAC
5.2 A
1100 W
DC
N/A
4265
N/A
-48 –(-60) V
1870 W
1100 W
N/A
1870 W
1100 W
27.0 A
1400 W
AC
Platinum
5459
50/60 Hz
100-240 V
2380 W
1400 W
1400 W
1785 W
1050 W
12–8 A
1400 W
Mixed mode
N/A
5459
N/A
240 V
6.6 A
Supported operating systems
The XC Core XC750 supports the following operating systems:
Maintain optimum thermal performance on the XC Core XC750 using various cooling components based on the following:
CPU TDP
Storage modules and rear drives
GPU
Persistent memory.
The Dell XC Core XC750 offers air cooling.
Cooling fan specifications
The Dell XC Core XC750 supports up to six standard (STD), high-performance silver grade (HPR SLVR), or high-performance gold grade (HPR GOLD) cooling fans.
The following table provides the specifications for the fans that are used in the XC Core XC750:
Table 5. Cooling fan specificationsCooling fan specifications
Fan type
Abbreviation
Also known as
Label color
Label image
Standard fan
STD
STD
No label
Standard fan
High performance (Silver grade) fan
HPR (SLVR)
HPR
Silver
New cooling fans come with the High Performance Silver Grade label. The older cooling fans have the High Performance label.
High performance (Silver grade) fan
High performance (Gold grade) fan
HPR (Gold)
VHP - Very High Performance
Gold
New cooling fans come with the High Performance Gold Grade label. The older cooling fans have the High Performance label.
High performance fan High performance (Gold grade) fan
Mixing of STD, HPR SLVR, or HPR GOLD fan is not supported.
The STD, HPR SLVR, or HPR GOLD fan installation depends on the XC Core XC750 configuration. For more information about the supported fan configuration or matrix, see Thermal restriction matrix.
System battery specifications
The XC Core XC750 supports CR 2032 3.0-V lithium coin cell system battery.
Expansion card riser specifications
The XC Core XC750 supports up to three slots and all PCI express (PCIe) Gen 4 expansion cards.
Boot Optimized Storage Subsystem (BOSS-S2): HW RAID 2 x M.2 SSDs 240 GB or 480 GB
Boot Optimized Storage Subsystem (BOSS-S1): HW RAID 2 x M.2 SSDs 240 GB or 480 GB
The software RAID S150 is supported on either of the following:
SATA drives with chipset SATA only backplane
NVMe drives in universal slots with processor direct PCIe cable connected backplane
Disk drive specifications
The XC Core XC750 supports the following disk drives:
12 x 3.5-inch hot-swappable SAS or SATA drives
24 x 2.5-inch hot-swappable SAS, SATA, or NVMe drives
2 x 2.5-inch rear hot-swappable SAS, SATA, or NVMe drives
16 x 2.5-inch hot-swappable NVMe drives
For more information about how to hot swap NVMe PCIe SSD U.2 device, see the
Dell Express Flash NVMe PCIe SSD User's Guide at
Dell Support (Browse all Products > Infrastructure > Data Center Infrastructure > Storage Adapters & Controllers > Dell PowerEdge Express Flash NVMe PCIe SSD > Select this product > Documentation > Manuals and Documents).
USB ports specifications
The following table provides specifications for the XC Core XC750 USB ports:
Table 10. USB ports specificationsUSB ports specifications.
Front
Front
Rear
Rear
Internal (Optional)
Internal (Optional)
USB port type
No. of ports
USB port type
No. of ports
USB port type
No. of ports
USB 2.0-compliant port
One
USB 2.0-compliant port
One
Internal USB 3.0-compliant port
One
Micro-USB, iDRAC Direct
One
USB 3.0-compliant port
One
Internal USB 3.0-compliant port
One
The micro USB 2.0 compliant port can only be used as an iDRAC Direct or a management port.
The USB 2.0 specifications provide a 5 V supply on a single wire to power connected USB devices. A unit load is defined as 100 mA in USB 2.0, and 150 mA in USB 3.0. A device may draw a maximum of five unit loads (500 mA) from a port in USB 2.0; 6 (900 mA) in USB 3.0.
The USB 2.0 interface can provide power to low-power peripherals but must adhere to USB specification. An external power source is required for higher-power peripherals to function, such as external CD or DVD drives.
NIC port specifications
The XC Core XC750 supports up to two 10/100/1000 Mbps Network Interface Controller (NIC) ports. The ports are embedded on the LAN on Motherboard (LOM) and integrated on the optional OCP cards.
Table 11. NIC port specificationsNIC port specifications.
Feature
Specifications
LOM card
1 GB x 2
OCP card (OCP 3.0)
10 GbE x 2, 10 x GbE x 4, 25 GbE x 2, 25 GbE x 4
Serial connector specifications
The XC Core XC750 supports one optional card type serial connector, which is a 9-pin connector, Data Terminal Equipment (DTE), 16550-compliant .
The optional serial connector card is installed similar to an expansion card filler bracket.
VGA ports specifications
The Dell XC Core XC750 supports One DB-15 VGA port one each on the front and back (optional for liquid cooling) panels.
Video specifications
The XC Core XC750 supports integrated Matrox G200 graphics controller with 16 MB of video frame buffer. The following table describes the supported video resolutions:
Table 12. Video specificationsVideo specifications.
Resolution
Refresh rate (Hz)
Color depth (bits)
1024 x 768
60
8, 16, 32
1280 x 800
60
8, 16, 32
1280 x 1024
60
8, 16, 32
1360 x 768
60
8, 16, 32
1440 x 900
60
8, 16, 32
1600 x 900
60
8, 16, 32
1600 x 1200
60
8, 16, 32
1680 x 1050
60
8, 16, 32
1920 x 1080
60
8, 16, 32
1920 x 1200
60
8, 16, 32
Environmental specifications
NOTE:For additional information about environmental certifications, see the product environmental datasheet that is located with the
Manuals & Documents on
Dell Support.
The following table provides information for operational climatic range, category A2:
The following table provides the processor and heat sink matrix:
Table 20. Processor and heat sink matrixProcessor and heat sink matrix.
Heat sink
Processor TDP
1U STD HSK
<= 165 W (for non-GPU)
T-Type HSK
For all TDP with GPU, and 256 GB LRDIMM configurations
2U HPR HSK
>165 W (for non-GPU configurations)
The following table provides the thermal restriction matrix with <= 64 GB RDIMM (non-GPU)
Table 21. Thermal restriction matrix with <= 64 GB RDIMMThermal restriction matrix with <= 64 GB RDIMM.
Configuration
24 x 2.5-inch SAS or SATA
16 x 2.5-inch SAS + 8 x 2.5-inch NVMe
12 x 3.5-inch SAS or SATA
-
-
Ambient temperature
Rear storage
No Rear Drives
2 x Rear 2.5-inch, no rear fan
4 x Rear 2.5-inch with fan
No Rear Drives
No Rear Drives
2 x Rear 2.5-inch, no rear fan
4 x Rear 2.5-inch with fan
-
CPU TDP or cTDP
105 W
-
HPR SLVR fan
STD fan
HPR SLVR fan
HPR SLVR fan
35°C (95°F)
120 W
35°C (95°F)
125 W
35°C (95°F)
135 W
35°C (95°F)
140 W
35°C (95°F)
150 W
35°C (95°F)
165 W
35°C (95°F)
185 W
HPR SLVR fan
35°C (95°F)
195 W
35°C (95°F)
205 W
HPR Gold fan
35°C (95°F)
225 W
35°C (95°F)
230 W
HPR SLVR fan *
30°C (86°F)
235 W
30°C (86°F)
240 W
30°C (86°F)
250 W
30°C (86°F)
265 W
-
HPR SLVR fan
30°C (86°F)
270 W
-
HPR SLVR fan
30°C (86°F)
* Supported ambient temperature is 30°C (86°F).
The following table provides the thermal restriction matrix with 128 GB LRDIMM (Non-GPU).
Table 22. Thermal restriction matrix with 128 GB LRDIMMThermal restriction matrix with 128 GB LRDIMM.
Configuration
8 x 2.5-inch NVMe
16 x 2.5-inch SAS or SATA
16 x 2.5-inch NVMe
24 x 2.5-inch SAS or SATA
16 x 2.5-inch SAS + 8 x 2.5-inch NVMe
24 x 2.5-inch NVMe
12 x 3.5-inch SAS or SATA
-
-
Ambient temperature
Rear storage
No Rear Drives
No Rear Drives
No Rear Drives
No Rear Drives
2 x Rear 2.5-inch, no rear fan
4 x Rear 2.5-inch with fan
No Rear Drives
No Rear Drives
No Rear Drives
2 x Rear 2.5-inch, no rear fan
4 x Rear 2.5-inch with fan
-
CPU TDP or cTDP
105 W
STD fan
HPR SLVR fan
HPR SLVR fan
HPR SLVR fan
HPR Gold fan
HPR SLVR fan
HPR SLVR fan *
35°C (95°F)
-
120 W
35°C (95°F)
-
125 W
35°C (95°F)
-
135 W
35°C (95°F)
-
140 W
35°C (95°F)
-
150 W
35°C (95°F)
-
165 W
35°C (95°F)
-
185 W
30°C (86°F)
-
195 W
30°C (86°F)
-
205 W
HPR Gold fan
30°C (86°F)
-
225 W
Not supported
30°C (86°F)
-
230 W
30°C (86°F)
-
235 W
30°C (86°F)
-
240 W
30°C (86°F)
-
250 W
30°C (86°F)
-
265 W
STD fan
HPR SLVR fan
Not supported
30°C (86°F)
-
270 W
STD fan
HPR SLVR fan
Not supported
30°C (86°F)
* Supported ambient temperature is 30°C (86°F).
The following table provides the thermal restriction matrix with 256 GB LRDIMM (Non-GPU)
Table 23. Thermal restriction matrix with 256 GB LRDIMMThermal restriction matrix with 256 GB LRDIMM.
Configuration
8 x 2.5-inch NVMe
16 x 2.5-inch SAS or SATA
16 x 2.5-inch NVMe
24 x 2.5-inch SAS/ SATA
16 x 2.5-inch SAS + 8 x 2.5-inch NVMe
24 x 2.5-inch NVMe
12 x 3.5-inch SAS or SATA
-
-
Ambient temperature
Rear storage
No Rear Drives
No Rear Drives
No Rear Drives
No Rear Drives
2 x Rear 2.5-inch, no rear fan
4 x Rear 2.5-inch with fan
No Rear Drives
No Rear Drives
No Rear Drives
2 x Rear 2.5-inch, no rear fan
4 x Rear 2.5-inch with fan
-
CPU TDP or cTDP
105 W
1DPC / 2 DPC HPR
1DPC
1DPC
Not supported
35°C (95°F)
-
120 W
35°C (95°F)
-
125 W
35°C (95°F)
-
135 W
35°C (95°F)
-
140 W
35°C (95°F)
-
150 W
35°C (95°F)
-
165 W
35°C (95°F)
-
185 W
30°C (86°F)
-
195 W
30°C (86°F)
-
205 W
30°C (86°F)
-
225 W
30°C (86°F)
-
230 W
30°C (86°F)
-
235 W
30°C (86°F)
-
240 W
30°C (86°F)
-
250 W
30°C (86°F)
-
265 W
30°C (86°F)
-
270 W
30°C (86°F)
For all CPU TDP (105 W- 270 W) request HPR GOLD fan, T-Type HSK and processor HSK blank for 2.5-inch configurations.
For CPU TDP >165 W and riser configuration 1, 2, 3, or 4 supports maximum of four PCIe cards in Riser 1 or 2. This restriction is applicable for 8 x 2.5-inch NVMe, 16 x 2.5-inch SAS or SATA and 16 x 2.5-inch NVMe system configurations.
The following table provides the thermal restriction with <=128 GB DIMM (GPU):
Table 24. Thermal restrictionThermal restriction.
Configuration (Front storage)
Fan type
CPU TDP or cTDP
GPU (Ambient temperature)
A100 (80G)
A100
A40 (max 2)
A30
A10
M10 (max 2)
T4 (max 6)
24 x 2.5-inch SAS
HPR GOLD fan
270 W
35°C (95°F)
35°C (95°F)
35°C (95°F)
35°C (95°F)
35°C (95°F)
35°C (95°F)
30°C (86°F)
16 x 2.5-inch SAS + 8 x 2.5-inch NVMe
HPR SLVR fan
270 W
35°C (95°F)
35°C (95°F)
35°C (95°F)
35°C (95°F)
35°C (95°F)
35°C (95°F)
30°C (86°F)
GPU cards are not supported in 12 x 3.5-inch drive and rear drive configuration systems.
All GPU cards require 1U T-type HSK and GPU shroud.
T4 GPU is not supported on riser 2 in 8 x 3.5-inch configuration.
Other restrictions for air cooling configurations
Kioxia CM6/CD6 NVMeSSD are not supported on rear drive module.
Samsung 1733v2/1735v2 NVMeSSD are not supported on 12 x 3.5-inch rear drive module.
ICX XCC Platinum 8368Q 270W-38C CPU in air cooling system is not supported.
25 Gb and above PCIe or OCP cards require high temperature (85°C (185°F)) active optics cable.
Requires 2U-HPR HSK(8F34X) to support "ICX HCC Gold 6334 165W-8C CPU" in non-GPU configuration.
Requires HPR GOLD fan to support BOSS-S1 on 2.5-inch configuration and not supported on 3.5-inch configuration.
Shroud, heat sink, and riser cage restriction
The following table provides the restrictions with shroud, heat sink, and riser cage:
Table 25. PCIe card typePCIe card type.
PCIe card type
Form factor
Fan
Processor heat sink
Shroud
Riser cage
GPU
FL
Configuration dependency
T-type (1U-EXT)
GPU shroud
long
-
HL
short
Non-GPU
FL
long
-
short
-
long
-
HL
1U-STD or 2U-HPR
STD shroud
short
Thermal air restrictions
ASHRAE A3 environment for air cooling configuration
Two PSUs are required in redundant mode. If there is PSU failure, system performance may be reduced.
PCIe SSD is not supported.
BPS, 128 GB, or greater capacity DIMMs are not supported.
GPU and FPGA are not supported.
Processor TDP greater than 165 W are not supported.
HPR SLVR fans are required.
Front storage is not supported in 12 x 3.5-inch SAS configuration.
Rear drives are not supported.
Non-Dell qualified peripheral cards and peripheral cards greater than 25 W are not supported.
OCP 3.0 card is supported with 85°C (185°F) active optic cable.
BOSS 1.5 card is supported.
ASHRAE A4 environment for air cooling configuration
Two PSUs are required in redundant mode. If there is PSU failure, system performance may be reduced.
PCIe SSD is not supported.
BPS, 128 GB, or greater capacity DIMMs are not supported.
GPU and FPGA are not supported.
Processor TDP greater than 120 W are not supported.
HPR SLVR fans are required.
Front storage is not supported in 12 x 3.5-inch SAS configuration.
Rear drives are not supported.
BOSS 1.5 is not supported.
OCP 3.0 card is supported with 85°C (185°F) active optic cable and cards tier ?4.
Non-Dell qualified peripheral cards and peripheral cards greater than 25 W are not supported.
Particulate and gaseous contamination specifications
If the levels of particulate or gaseous pollution exceed the specified limitations and result in equipment damage or failure, you must rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer. The following table defines the limitations that help avoid any equipment damage or failure from particulate and gaseous contamination:
Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit.
The ISO Class 8 condition applies to data center environments only. This air filtration requirement does not apply to IT equipment designed to be used outside a data center. For example, the requirement does not apply in environments such as an office or factory floor.
Air entering the data center must have MERV11 or MERV13 filtration.
Conductive dust
Air must be free of conductive dust, zinc whiskers, or other conductive particles.
This condition applies to data center and nondata center environments.
Corrosive dust
Air must be free of corrosive dust.
Residual dust present in the air must have a deliquescent point less than 60% relative humidity.
This condition applies to data center and nondata center environments.
The following table provides the gaseous contamination specifications: