XC750 technical specifications

Specifications for the components of the XC750 are provided.

The following XC750 specifications are provided:

  • Chassis dimensions
  • Weight
  • Processor
  • Power supply units
  • Supported operating systems
  • Cooling fans
  • System battery
  • Expansion card risers
  • Memory
  • Storage controller
  • Disk drives
  • USB ports
  • NIC ports
  • Serial ports
  • VGA ports
  • Video
  • Environment
  • Particulate and gaseous contamination
  • Thermal restrictions

Chassis dimensions

Figure 1. Chassis dimensions
Chassis dimensions

The following table provides the chassis dimensions for the XC Core XC750:

Table 1. Chassis dimensionsChassis dimensions.
Drives Xa Xb Y Za Zb Zc
0/8/12/16/24 drives 482 mm (18.97 in) 434 mm (17.08 in) 86.8 mm (3.41 in) 35.84 mm (1.4 in) with bezel

22 mm (0.86 in) without bezel
700.7 mm (27.58 in)

Ear to rear wall
736.29 mm (28.92 in)

Ear to PSU handle

Zb is the nominal rear wall external surface where the XC Core XC750 board I/O connectors reside.

Chassis weight

The following table provides the XC Core XC750 weight specifications:

Table 2. Chassis weight specificationsChassis weight specifications.
System configuration Maximum weight (with all drives/SSDs)
12 x 3.5-inch 35.3 kg (77.82 lb)
16 x 2.5-inch 32.6 kg (71.87 lb)
24 x 2.5-inch 35.2 kg (77.60 lb)

Processor specifications

The following table provides processor specifications for the XC Core XC750.

Table 3. Processor specificationsProcessor specifications.
Supported processor Number of processors supported
Third-generation Intel Xeon Scalable processors with up to 40 cores Two

PSU specifications

The XC Core XC750 supports up to two AC or DC power supply units (PSUs).

WARNING: Instructions for the qualified electricians only:

System using -(48-60) V DC or 240 V DC power supplies are intended for restricted access locations. See Articles 110-5, 110-6, 110-11, 110-14, and 110-17 of the National Electrical Code, American National Standards Institute (ANSI)/National Fire Protection Association (NFPA) 70.

If applicable in the country or region of use, 240 V DC power supplies shall be connected to the 240 V DC outlet from certified power distribution units.

Power supply cords and jumper cords and the associated plugs, inlets, and connectors shall have appropriate electrical ratings. The rating shall reference the rating label on the system when used for connection.

Table 4. PSU specificationsPSU specifications.
PSU Class Heat dissipation (maximum BTU/hr) Frequency

(Hz)

Voltage AC Current
High line 200–240 V Low line 100–120 V
Peak Power - Peak Power -
-72 VDC -72 VDC 240 VDC -40 VDC 40 VDC
800 W AC Platinum 3139 50/60 100–240 V 1360 W 800 W 800 W 1360 W 800 W 9.2 - 4.7 A
800 W

Mixed mode

N/A 3139 N/A 240 V 3.8 A
1100 W

AC

Titanium 4299 50/60 Hz 100-240 V 1870 W 1100 W 1100 W 1785 W 1050 W 12 - 6.3 A
1100 W

Mixed mode

N/A 4299 N/A 240 VAC 5.2 A
1100 W

DC

N/A 4265 N/A -48 –(-60) V 1870 W 1100 W N/A 1870 W 1100 W 27.0 A
1400 W

AC

Platinum 5459 50/60 Hz 100-240 V 2380 W 1400 W 1400 W 1785 W 1050 W 12–8 A
1400 W

Mixed mode

N/A 5459 N/A 240 V 6.6 A

Supported operating systems

The XC Core XC750 supports the following operating systems:

  • Windows Server with Hyper-V (XC750-14 only)
  • VMware ESXi
  • AHV

For more information, go to Dell | Server Operating System Support.

Cooling options

Maintain optimum thermal performance on the XC Core XC750 using various cooling components based on the following:

  • CPU TDP
  • Storage modules and rear drives
  • GPU
  • Persistent memory.

The Dell XC Core XC750 offers air cooling.

Cooling fan specifications

The Dell XC Core XC750 supports up to six standard (STD), high-performance silver grade (HPR SLVR), or high-performance gold grade (HPR GOLD) cooling fans.

The following table provides the specifications for the fans that are used in the XC Core XC750:

Table 5. Cooling fan specificationsCooling fan specifications
Fan type Abbreviation Also known as Label color Label image
Standard fan STD STD No label Standard fan

Standard fan

High performance (Silver grade) fan HPR (SLVR) HPR Silver New cooling fans come with the High Performance Silver Grade label. The older cooling fans have the High Performance label.

High Performance Silver Grade label

High performance (Silver grade) fan

High performance (Silver grade) fan
High performance (Gold grade) fan HPR (Gold) VHP - Very High Performance Gold New cooling fans come with the High Performance Gold Grade label. The older cooling fans have the High Performance label.

High Performance Gold Grade label

High performance fan High performance (Gold grade) fan

High performance fan High performance (Gold grade) fan

Mixing of STD, HPR SLVR, or HPR GOLD fan is not supported.

The STD, HPR SLVR, or HPR GOLD fan installation depends on the XC Core XC750 configuration. For more information about the supported fan configuration or matrix, see Thermal restriction matrix.

System battery specifications

The XC Core XC750 supports CR 2032 3.0-V lithium coin cell system battery.

Expansion card riser specifications

The XC Core XC750 supports up to three slots and all PCI express (PCIe) Gen 4 expansion cards.

Table 6. Expansion card riser specificationsExpansion card riser specifications.
PCIe slot With Regular shroud With GPGPU shroud R1a R1b R1c R2a R2b R3a R3b R4a Rb
Slot 1 Full height

Half length
Full height

Full length
- x8 x16

(single-width (SW) GPU)
- - - - - -
Slot 2 Full height

Half length
Full height

Full length
x16

(double- width (DW) GPU)
x8 x16

(SW GPU)
- - - - - -
Slot 3 Low profile

Half length
Low profile

Half length
N/A - - x16 - - - - -
Slot 3 SNAPI Low profile

Half length
Low profile

Half length
- - - - x16 - - - -
Slot 4 Full height

Half length
N/A - - - - - - x8 - -
Slot 5 Full height

Half length
Full height

Half length
- - - - - x16 x8 - -
Slot 6 Low profile

Half length
Low profile

Half length
- - - x16 x8 - - - -
Slot 7 Full height

Half length
Full height

Full length
- - - - - - - x16 (DW GPU x8
Slot 8 Full height

Half length
N/A - - - - - - - - x8
WARNING:Do not install or use a consumer-grade GPU in the Enterprise Server products.

Memory specifications

The XC Core XC750 supports the following memory specifications for optimized operation:

Table 7. Memory specificationsMemory specifications.
DIMM type DIMM rank DIMM capacity Single processor Dual processor
Minimum RAM Maximum RAM Minimum RAM Maximum RAM
RDIMM Single rank 8 GB 8 GB 128 GB 16 GB 256 GB
Dual rank 16 GB 16 GB 256 GB 32 GB 512 GB
32 GB 32 GB 512 GB 64 GB 1 TB
64 GB 64 GB 1 TB 128 GB 2 TB
LRDIMM Quad rank 128 GB 128 GB 2 TB 256 GB 4 TB
Octa rank 256 GB 256 GB 4 TB 512 GB 8 TB

The following table describes the memory module socket specifications:

Table 8. Memory module socket specificationsMemory module socket specifications.
Memory module sockets Speed
32, 288-pin 3200 MT/s, 2933 MT/s

Storage controller specifications

The XC Core XC750 supports the storage controller card in the following table:

Table 9. Storage controller specificationsStorage controller specifications.
Internal controllers
  • HBA355I
  • Boot Optimized Storage Subsystem (BOSS-S2): HW RAID 2 x M.2 SSDs 240 GB or 480 GB
  • Boot Optimized Storage Subsystem (BOSS-S1): HW RAID 2 x M.2 SSDs 240 GB or 480 GB

The software RAID S150 is supported on either of the following:

  • SATA drives with chipset SATA only backplane
  • NVMe drives in universal slots with processor direct PCIe cable connected backplane

Disk drive specifications

The XC Core XC750 supports the following disk drives:

  • 12 x 3.5-inch hot-swappable SAS or SATA drives
  • 24 x 2.5-inch hot-swappable SAS, SATA, or NVMe drives
  • 2 x 2.5-inch rear hot-swappable SAS, SATA, or NVMe drives
  • 16 x 2.5-inch hot-swappable NVMe drives

For more information about how to hot swap NVMe PCIe SSD U.2 device, see the Dell Express Flash NVMe PCIe SSD User's Guide at Dell Support (Browse all Products > Infrastructure > Data Center Infrastructure > Storage Adapters & Controllers > Dell PowerEdge Express Flash NVMe PCIe SSD > Select this product > Documentation > Manuals and Documents).

USB ports specifications

The following table provides specifications for the XC Core XC750 USB ports:

Table 10. USB ports specificationsUSB ports specifications.
Front Front Rear Rear Internal (Optional) Internal (Optional)
USB port type No. of ports USB port type No. of ports USB port type No. of ports
USB 2.0-compliant port One USB 2.0-compliant port One Internal USB 3.0-compliant port One
Micro-USB, iDRAC Direct One USB 3.0-compliant port One Internal USB 3.0-compliant port One

The micro USB 2.0 compliant port can only be used as an iDRAC Direct or a management port.

The USB 2.0 specifications provide a 5 V supply on a single wire to power connected USB devices. A unit load is defined as 100 mA in USB 2.0, and 150 mA in USB 3.0. A device may draw a maximum of five unit loads (500 mA) from a port in USB 2.0; 6 (900 mA) in USB 3.0.

The USB 2.0 interface can provide power to low-power peripherals but must adhere to USB specification. An external power source is required for higher-power peripherals to function, such as external CD or DVD drives.

NIC port specifications

The XC Core XC750 supports up to two 10/100/1000 Mbps Network Interface Controller (NIC) ports. The ports are embedded on the LAN on Motherboard (LOM) and integrated on the optional OCP cards.

Table 11. NIC port specificationsNIC port specifications.
Feature Specifications
LOM card 1 GB x 2
OCP card (OCP 3.0) 10 GbE x 2, 10 x GbE x 4, 25 GbE x 2, 25 GbE x 4

Serial connector specifications

The XC Core XC750 supports one optional card type serial connector, which is a 9-pin connector, Data Terminal Equipment (DTE), 16550-compliant .

The optional serial connector card is installed similar to an expansion card filler bracket.

VGA ports specifications

The Dell XC Core XC750 supports One DB-15 VGA port one each on the front and back (optional for liquid cooling) panels.

Video specifications

The XC Core XC750 supports integrated Matrox G200 graphics controller with 16 MB of video frame buffer. The following table describes the supported video resolutions:

Table 12. Video specificationsVideo specifications.
Resolution Refresh rate (Hz) Color depth (bits)
1024 x 768 60 8, 16, 32
1280 x 800 60 8, 16, 32
1280 x 1024 60 8, 16, 32
1360 x 768 60 8, 16, 32
1440 x 900 60 8, 16, 32
1600 x 900 60 8, 16, 32
1600 x 1200 60 8, 16, 32
1680 x 1050 60 8, 16, 32
1920 x 1080 60 8, 16, 32
1920 x 1200 60 8, 16, 32

Environmental specifications

NOTE:For additional information about environmental certifications, see the product environmental datasheet that is located with the Manuals & Documents on Dell Support.

The following table provides information for operational climatic range, category A2:

Table 13. Environmental specificationsEnvironmental specifications.
Temperature Specifications
Allowable continuous operations
Temperature ranges for altitudes <= 900 m (<= 2,953 ft) 10–35°C (50–95°F) with no direct sunlight on the equipment
Humidity percent ranges (noncondensing always) Minimum: 8% RH with -12°C (10.4°F) dew point

Maximum: 80% RH with 21°C (69.8°F) dew point
Operational altitude derating Reduce the maximum temperature by 1°C/300 m (1.8°F/984 ft) above 900 m (2953 ft)

The following table provides information for operational climatic range, category A3:

Table 14. Operational climatic range, category A3Operational climatic range, category A3.
Temperature Specifications
Allowable continuous operations
Temperature ranges for altitudes <= 900 m (<= 2953 ft) 5–40°C (41–104°F) with no direct sunlight on the equipment
Humidity percent ranges (noncondensing always) Minimum: 8% RH with -12°C (10.4°F) dew point

Maximum: 85% RH with 24°C (75.2°F) dew point
Operational altitude derating Reduce the maximum temperature by 1°C/175 m (33.8°F/574 ft) above 900 m (2953 ft)

The following table provides information for operational climatic range, category A4:

Table 15. Operational climatic range, category A4Operational climatic range, category A4.
Temperature Specifications
Allowable continuous operations
Temperature ranges for altitudes <= 900 m (<= 2953 ft) 5–45°C (41–113°F) with no direct sunlight on the equipment
Humidity percent ranges (noncondensing always) Minimum: 8% RH with -12°C (10.4°F) dew point

Maximum: 90% RH with 24°C (75.2°F) dew point
Operational altitude derating Reduce the maximum temperature by 1°C/125 m (33.8°F/410 ft) above 900 m (2953 ft)

The following table provides information for shared requirements across all categories:

Table 16. Shared requirementsShared requirements.
Temperature Specifications
Allowable continuous operations
Maximum temperature gradient (applies to both operation and nonoperation) 20°C (36°F) in an hour* and 5°C (9°F) in 15 minutes

For tape: 5°C (9°F) in an hour*
NOTE:Per ASHRAE thermal guidelines for tape hardware these rates are not instantaneous.
Nonoperational temperature limits -40°C to 65°C (-40°F to 149°F)
Nonoperational humidity limits 5% to 95% RH with 27°C (80.6°F) maximum dew point
Maximum nonoperational altitude 12,000 meters (39,370 ft)
Maximum operational altitude 3,048 meters (10,000 ft)

The following table specifies the maximum allowed vibration:

Table 17. Maximum allowed vibrationMaximum allowed vibration.
Maximum vibration Specifications
Operating 0.26 Grms at 5 Hz to 350 Hz (all operation orientations)
Storage 1.88 Grms at 10 Hz to 500 Hz for 15 minutes

(all six sides tested)

The following table specifies the shock pulse maxima:

Table 18. Shock pulse maximaShock pulse maxima.
Maximum shock pulse Specifications
Operating Six consecutive shock pulses in the positive and negative x, y, and z axis of 6 G for up to 11 milliseconds
Storage Six consecutive shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 milliseconds

Thermal restriction matrix

The following table describes label references:

Table 19. Thermal restriction matrixThermal restriction matrix.
Label Explanation
STD Standard
HPR High Performance
HSK Heat sink
LP Low Profile (Riser)
FH Full Height (Riser)
DW Double Wide (Xilinx FPGA accelerator)

The following table provides the processor and heat sink matrix:

Table 20. Processor and heat sink matrixProcessor and heat sink matrix.
Heat sink Processor TDP
1U STD HSK <= 165 W (for non-GPU)
T-Type HSK For all TDP with GPU, and 256 GB LRDIMM configurations
2U HPR HSK >165 W (for non-GPU configurations)

The following table provides the thermal restriction matrix with <= 64 GB RDIMM (non-GPU)

Table 21. Thermal restriction matrix with <= 64 GB RDIMMThermal restriction matrix with <= 64 GB RDIMM.
Configuration 24 x 2.5-inch SAS or SATA 16 x 2.5-inch SAS + 8 x 2.5-inch NVMe 12 x 3.5-inch SAS or SATA - - Ambient temperature
Rear storage No Rear Drives 2 x Rear 2.5-inch, no rear fan 4 x Rear 2.5-inch with fan No Rear Drives No Rear Drives 2 x Rear 2.5-inch, no rear fan 4 x Rear 2.5-inch with fan -
CPU TDP or cTDP 105 W - HPR SLVR fan STD fan HPR SLVR fan HPR SLVR fan 35°C (95°F)
120 W 35°C (95°F)
125 W 35°C (95°F)
135 W 35°C (95°F)
140 W 35°C (95°F)
150 W 35°C (95°F)
165 W 35°C (95°F)
185 W HPR SLVR fan 35°C (95°F)
195 W 35°C (95°F)
205 W HPR Gold fan 35°C (95°F)
225 W 35°C (95°F)
230 W HPR SLVR fan * 30°C (86°F)
235 W 30°C (86°F)
240 W 30°C (86°F)
250 W 30°C (86°F)
265 W - HPR SLVR fan 30°C (86°F)
270 W - HPR SLVR fan 30°C (86°F)

* Supported ambient temperature is 30°C (86°F).

The following table provides the thermal restriction matrix with 128 GB LRDIMM (Non-GPU).

Table 22. Thermal restriction matrix with 128 GB LRDIMMThermal restriction matrix with 128 GB LRDIMM.
Configuration 8 x 2.5-inch NVMe 16 x 2.5-inch SAS or SATA 16 x 2.5-inch NVMe 24 x 2.5-inch SAS or SATA 16 x 2.5-inch SAS + 8 x 2.5-inch NVMe 24 x 2.5-inch NVMe 12 x 3.5-inch SAS or SATA - - Ambient temperature
Rear storage No Rear Drives No Rear Drives No Rear Drives No Rear Drives 2 x Rear 2.5-inch, no rear fan 4 x Rear 2.5-inch with fan No Rear Drives No Rear Drives No Rear Drives 2 x Rear 2.5-inch, no rear fan 4 x Rear 2.5-inch with fan -
CPU TDP or cTDP 105 W STD fan HPR SLVR fan HPR SLVR fan HPR SLVR fan HPR Gold fan HPR SLVR fan HPR SLVR fan * 35°C (95°F)
- 120 W 35°C (95°F)
- 125 W 35°C (95°F)
- 135 W 35°C (95°F)
- 140 W 35°C (95°F)
- 150 W 35°C (95°F)
- 165 W 35°C (95°F)
- 185 W 30°C (86°F)
- 195 W 30°C (86°F)
- 205 W HPR Gold fan 30°C (86°F)
- 225 W Not supported 30°C (86°F)
- 230 W 30°C (86°F)
- 235 W 30°C (86°F)
- 240 W 30°C (86°F)
- 250 W 30°C (86°F)
- 265 W STD fan HPR SLVR fan Not supported 30°C (86°F)
- 270 W STD fan HPR SLVR fan Not supported 30°C (86°F)

* Supported ambient temperature is 30°C (86°F).

The following table provides the thermal restriction matrix with 256 GB LRDIMM (Non-GPU)

Table 23. Thermal restriction matrix with 256 GB LRDIMMThermal restriction matrix with 256 GB LRDIMM.
Configuration 8 x 2.5-inch NVMe 16 x 2.5-inch SAS or SATA 16 x 2.5-inch NVMe 24 x 2.5-inch SAS/ SATA 16 x 2.5-inch SAS + 8 x 2.5-inch NVMe 24 x 2.5-inch NVMe 12 x 3.5-inch SAS or SATA - - Ambient temperature
Rear storage No Rear Drives No Rear Drives No Rear Drives No Rear Drives 2 x Rear 2.5-inch, no rear fan 4 x Rear 2.5-inch with fan No Rear Drives No Rear Drives No Rear Drives 2 x Rear 2.5-inch, no rear fan 4 x Rear 2.5-inch with fan -
CPU TDP or cTDP 105 W 1DPC / 2 DPC HPR 1DPC 1DPC Not supported 35°C (95°F)
- 120 W 35°C (95°F)
- 125 W 35°C (95°F)
- 135 W 35°C (95°F)
- 140 W 35°C (95°F)
- 150 W 35°C (95°F)
- 165 W 35°C (95°F)
- 185 W 30°C (86°F)
- 195 W 30°C (86°F)
- 205 W 30°C (86°F)
- 225 W 30°C (86°F)
- 230 W 30°C (86°F)
- 235 W 30°C (86°F)
- 240 W 30°C (86°F)
- 250 W 30°C (86°F)
- 265 W 30°C (86°F)
- 270 W 30°C (86°F)

For all CPU TDP (105 W- 270 W) request HPR GOLD fan, T-Type HSK and processor HSK blank for 2.5-inch configurations.

For CPU TDP >165 W and riser configuration 1, 2, 3, or 4 supports maximum of four PCIe cards in Riser 1 or 2. This restriction is applicable for 8 x 2.5-inch NVMe, 16 x 2.5-inch SAS or SATA and 16 x 2.5-inch NVMe system configurations.

The following table provides the thermal restriction with <=128 GB DIMM (GPU):

Table 24. Thermal restrictionThermal restriction.
Configuration (Front storage) Fan type CPU TDP or cTDP GPU (Ambient temperature)
A100 (80G) A100 A40 (max 2) A30 A10 M10 (max 2) T4 (max 6)
24 x 2.5-inch SAS HPR GOLD fan 270 W 35°C (95°F) 35°C (95°F) 35°C (95°F) 35°C (95°F) 35°C (95°F) 35°C (95°F) 30°C (86°F)
16 x 2.5-inch SAS + 8 x 2.5-inch NVMe HPR SLVR fan 270 W 35°C (95°F) 35°C (95°F) 35°C (95°F) 35°C (95°F) 35°C (95°F) 35°C (95°F) 30°C (86°F)

GPU cards are not supported in 12 x 3.5-inch drive and rear drive configuration systems.

All GPU cards require 1U T-type HSK and GPU shroud.

T4 GPU is not supported on riser 2 in 8 x 3.5-inch configuration.

Other restrictions for air cooling configurations

  • Kioxia CM6/CD6 NVMeSSD are not supported on rear drive module.
  • Samsung 1733v2/1735v2 NVMeSSD are not supported on 12 x 3.5-inch rear drive module.
  • ICX XCC Platinum 8368Q 270W-38C CPU in air cooling system is not supported.
  • 25 Gb and above PCIe or OCP cards require high temperature (85°C (185°F)) active optics cable.
  • Requires 2U-HPR HSK(8F34X) to support "ICX HCC Gold 6334 165W-8C CPU" in non-GPU configuration.
  • Requires HPR GOLD fan to support BOSS-S1 on 2.5-inch configuration and not supported on 3.5-inch configuration.

Shroud, heat sink, and riser cage restriction

The following table provides the restrictions with shroud, heat sink, and riser cage:

Table 25. PCIe card typePCIe card type.
PCIe card type Form factor Fan Processor heat sink Shroud Riser cage
GPU FL Configuration dependency T-type (1U-EXT) GPU shroud long
- HL short
Non-GPU FL long
- short
- long
- HL 1U-STD or 2U-HPR STD shroud short

Thermal air restrictions

ASHRAE A3 environment for air cooling configuration

  • Two PSUs are required in redundant mode. If there is PSU failure, system performance may be reduced.
  • PCIe SSD is not supported.
  • BPS, 128 GB, or greater capacity DIMMs are not supported.
  • GPU and FPGA are not supported.
  • Processor TDP greater than 165 W are not supported.
  • HPR SLVR fans are required.
  • Front storage is not supported in 12 x 3.5-inch SAS configuration.
  • Rear drives are not supported.
  • Non-Dell qualified peripheral cards and peripheral cards greater than 25 W are not supported.
  • OCP 3.0 card is supported with 85°C (185°F) active optic cable.
  • BOSS 1.5 card is supported.

ASHRAE A4 environment for air cooling configuration

  • Two PSUs are required in redundant mode. If there is PSU failure, system performance may be reduced.
  • PCIe SSD is not supported.
  • BPS, 128 GB, or greater capacity DIMMs are not supported.
  • GPU and FPGA are not supported.
  • Processor TDP greater than 120 W are not supported.
  • HPR SLVR fans are required.
  • Front storage is not supported in 12 x 3.5-inch SAS configuration.
  • Rear drives are not supported.
  • BOSS 1.5 is not supported.
  • OCP 3.0 card is supported with 85°C (185°F) active optic cable and cards tier ?4.
  • Non-Dell qualified peripheral cards and peripheral cards greater than 25 W are not supported.

Particulate and gaseous contamination specifications

If the levels of particulate or gaseous pollution exceed the specified limitations and result in equipment damage or failure, you must rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer. The following table defines the limitations that help avoid any equipment damage or failure from particulate and gaseous contamination:

Table 26. Particulate contamination specificationsParticulate contamination specifications.
Particulate contamination Specifications
Air filtration Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit.

The ISO Class 8 condition applies to data center environments only. This air filtration requirement does not apply to IT equipment designed to be used outside a data center. For example, the requirement does not apply in environments such as an office or factory floor.

Air entering the data center must have MERV11 or MERV13 filtration.
Conductive dust Air must be free of conductive dust, zinc whiskers, or other conductive particles.

This condition applies to data center and nondata center environments.
Corrosive dust Air must be free of corrosive dust.

Residual dust present in the air must have a deliquescent point less than 60% relative humidity.

This condition applies to data center and nondata center environments.

The following table provides the gaseous contamination specifications:

Table 27. Gaseous contamination specificationsGaseous contamination specifications.
Gaseous contamination Specifications
Copper coupon corrosion rate <300 Å/month per Class G1 as defined by ANSI/ISA71.04-2013.
Silver coupon corrosion rate <200 Å/month as defined by ANSI/ISA71.04-2013.