Specifications for the components of the XC750xa are provided.
The following XC750xa specifications are provided:
Chassis dimensions
Weight
Processor
Power supply units
Supported operating systems
Cooling fans
System battery
Expansion card risers
Memory
Storage controller
Disk drives
USB ports
NIC ports
Serial ports
VGA ports
Video
Environment
Particulate and gaseous contamination
Thermal restrictions
Chassis dimensions
The following table provides the chassis dimensions for the XC Core XC750xa:
Table 1. Chassis dimensions for the XC Core XC750xaChassis dimensions for the XC Core XC750xa
Drives
Xa
Xb
Y
Za
Zb
Zc
Eight drives
482 mm (18.97 in)
434 mm (17.08 in)
86.8 mm (3.41 in)
35.84 mm (1.4 in) with bezel
22 mm (0.86 in) without bezel
837.2 mm (32.96 in)
Ear to rear wall
872.8 mm (34.36 in)
Ear to PSU handle
Zb is the nominal rear wall external surface where the system board I/O connectors reside.
Chassis weight
The following table provides the XC Core XC750xa weight specifications:
Table 2. Chassis weightChassis weight
System configuration
Maximum weight (with all drives/SSDs)
8 x 2.5-inch + 4 x DW-FL cards (front) + 4 x PCIe cards (rear)
34.9 kg (76.94 lb)
Processor specifications
The XC Core XC750xa supports two 3rd Generation Intel Xeon Scalable processors with up to 40 cores.
PSU specifications
The XC Core XC750xa supports up to two AC or DC power supply units (PSUs).
WARNING:Instructions for the qualified electricians only:
Systems using -(48-60) V DC or 240 V DC power supplies are intended for restricted access locations. See Articles 110-5, 110-6, 110-11, 110-14, and 110-17 of the National Electrical Code, American National Standards Institute (ANSI)/National Fire Protection Association (NFPA) 70. If applicable in the country or region of use, 240 V DC power supplies shall be connected to the 240 V DC outlet from certified power distribution units.
Power supply cords and jumper cords and the associated plugs, inlets, and connectors shall have appropriate electrical ratings. The ratings shall reference the rating label on the system when used for connection.
The following table provides PSU specifications for the XC Core XC750xa:
Table 3. PSU specificationsPSU specifications
PSU
Class
Heat dissipation (maximum)
Frequency
Voltage
Peak power
N/A
N/A
Peak Power
N/A
Current
High line/-72 VDC
High line/-72 VDC
High line 240 VDC
Low line/-40 VDC
Low line/-40 VDC
1400 W AC
Platinum
5459 BTU/hr
50/60 Hz
100–240 V
2380 W
1400 W
1400 W
1785 W
1050 W
12–8 A
1400 W Mixed Mode HVDC (for China only)
N/A
5459 BTU/hr
N/A
240 V
2380 W
1400 W
1400 W
1785 W
1050 W
6.6 A
2400 W AC
Platinum
9213 BTU/hr
50/60 Hz
100–240 V
4080 W
2400 W
2400 W
2380 W
1400 W
16–13.5 A
2400 W Mixed Mode HVDC (for China only)
N/A
9213 BTU/hr
N/A
240 V
2380 W
1400 W
1400 W
1785 W
1050 W
11.2 A
Supported operating systems
The XC Core XC750xa supports the following operating systems:
8 GB RDIMM is not supported with Intel Persistent Memory 200 series (BPS).
Storage controller specifications
The XC Core XC750xa supports the following storage controller cards:
HBA355I
Boot Optimized Storage Subsystem (BOSS-S2): HWRAID 2 x M.2 SSDs 240 GB or 480 GB
Boot Optimized Storage Subsystem (BOSS-S1): HWRAID 2 x M.2 SSDs 240 GB or 480 GB
Disk drive specifications
The XC Core XC750xa supports 8 x 2.5-inch hot-swappable SAS, SATA drives, or NVMe drives.
For more information about how to hot swap NVMe PCIe SSD U.2 device, see the
Dell Express Flash NVMe PCIe SSD User's Guide at
Dell Support (Browse all Products > Infrastructure > Data Center Infrastructure > Storage Adapters & Controllers > Dell PowerEdge Express Flash NVMe PCIe SSD > Select this product > Documentation > Manuals and Documents).
USB ports specifications
The XC Core XC750xa supports the USB port types that are described in the following table:
Table 7. USB ports specificationsUSB ports specifications
Front
Front
Rear
Rear
Internal (Optional)
Internal (Optional)
USB port type
No. of ports
USB port type
No. of ports
USB port type
No. of ports
USB 2.0-compliant port
One
USB 2.0-compliant port
One
Internal USB 3.0-compliant port
One
Micro-USB 2.0, iDRAC Direct
One
USB 3.0-compliant ports
One
-
-
The micro USB 2.0 compliant port can only be used as an iDRAC Direct or a management port.
The USB 2.0 specifications provide a 5 V supply on a single wire to power connected USB devices. A unit load is defined as 100 mA in USB 2.0, and 150 mA in USB 3.0. A device may draw a maximum of five unit loads (500 mA) from a port in USB 2.0; 6 (900 mA) in USB 3.0.
The USB 2.0 interface can provide power to low-power peripherals but must adhere to USB specification. An external power source is required for higher-power peripherals to function, such as external CD or DVD drives.
NIC ports specifications
The XC Core XC750xa supports up to two Network Interface Controller (NIC) ports. The ports are embedded on the LAN on the Motherboard (LOM) and integrated on the optional OCP cards. Details are provided in the following table:
Table 8. NIC ports specificationsNIC ports specifications
Feature
Specifications
LOM card
1 GbE x 2
OCP card (OCP 3.0)
10 GbE x 2, 10 GbE x 4, 25 GbE x 2, 25 GbE x 4
Serial connector specifications
The XC Core XC750xa supports one optional card type serial connector, which is a 9-pin connector, Data Terminal Equipment (DTE), 16550-compliant .
The optional serial connector card is installed similar to an expansion card filler bracket.
VGA port specifications
The XC Core XC750xa supports one DB-15 VGA.
Video specifications
The XC Core XC750xa supports an integrated Matrox G200 graphics controller with 16 MB of video frame buffer.
The following table describes the supported video resolutions:
Table 9. Supported video resolutionsSupported video resolutions
Resolution
Refresh rate (Hz)
Color depth (bits)
1024 x 768
60
8, 16, 32
1280 x 800
60
8, 16, 32
1280 x 1024
60
8, 16, 32
1360 x 768
60
8, 16, 32
1440 x 900
60
8, 16, 32
1600 x 900
60
8, 16, 32
1600 x 1200
60
8, 16, 32
1680 x 1050
60
8, 16, 32
1920 x 1080
60
8, 16, 32
1920 x 1200
60
8, 16, 32
Environmental specifications
NOTE:For additional information about environmental certifications, see the product environmental datasheet that is located with the
Manuals & Documents on
Dell Support.
The following table provides specifications for operational climatic range, category A2:
Table 10. Operational climatic range specifications, category A2Operational climatic range specifications, category A2
Temperature
Specifications
Allowable continuous operations
Temperature ranges for altitudes <900 m (<2953 ft)
10–-35°C (50–-95°F) with no direct sunlight on the equipment
Humidity percent ranges (noncondensing always)
Minimum: 8% RH with -12°C (53.6°F) dew point
Maximum: 80% RH with 21°C (69.8°F) dew point
Operational altitude derating
Reduce the maximum temperature by 1°C/300 m (33.8°F/984 ft) above 900 m (2953 ft).
The following table provides specifications for operational climatic range, category A3:
Table 11. Operational climatic range specifications, category A3Operational climatic range specifications, category A3
Temperature
Specifications
Allowable continuous operations
Temperature ranges for altitudes <900 m (< 2953 ft)
5–40°C (41–104°F) with no direct sunlight on the equipment
Humidity percent ranges (noncondensing always)
Minimum: 8% RH with -12°C (10.4°F) dew point
Maximum: 85% RH with 24°C (75.2°F) dew point
Operational altitude derating
Reduce the maximum temperature by 1°C/175 m (33.8°F/574 ft) above 900 m (2953 ft) .
The following table provides specifications for operational climatic range category A4:
Table 12. Operational climatic range specifications, category A4Operational climatic range specifications, category A4
Temperature
Specifications
Allowable continuous operations
Temperature ranges for altitudes <900 m (<2953 ft)
5–45°C (41–113°F) with no direct sunlight on the equipment
Humidity percent ranges (noncondensing always)
Minimum: 8% RH with -12°C (10.4°F) dew point
Maximum: 90% RH with 24°C (75.2°F) dew point
Operational altitude derating
Reduce the maximum temperature by 1°C/125 m (33.8°F/410 ft) above 900 m (2953 ft).
The following table provides specifications for shared requirements across all categories:
Table 13. Shared requirementsShared requirements.
Temperature
Specifications
Allowable continuous operations
Maximum temperature gradient (applies to both operation and nonoperation)
20°C (36°F) in an hour* and 5°C (9°F) in 15 minutes
For tape: 5°C (9°F) in an hour* (9°F in an hour)
NOTE:Per ASHRAE thermal guidelines for tape hardware these rates are not instantaneous temperature changes.
Nonoperational temperature limits
-40°C to 65°C (-104°F to 149°F)
Nonoperational humidity limits
5% to 95% RH with 27°C (80.6°F) maximum dew point
Maximum nonoperational altitude
12,000 m (39,370 ft)
Maximum operational altitude
3,048 meters (10,000 ft)
The following table provides the maximum vibration specifications:
Table 14. Maximum vibration specificationsMaximum vibration specifications
Maximum vibration
Specifications
Operating
0.21 Grms at 5 Hz to 500 Hz for 10 minutes (all operation orientations)
Storage
1.88 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested)
The following table provides the maximum shock pulse specifications:
Table 15. Maximum shock pulse specificationsMaximum shock pulse specifications.
Maximum shock pulse
Specifications
Operating
Six consecutive shock pulses in the positive and negative x, y, and z axis of 6 G for up to 11 milliseconds.
Storage
Six consecutive shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 milliseconds.
The following table describes label references:
Table 16. Label referencesLabel references.
Label
Explanation
STD
Standard
HPR
High Performance
HSK
Heat sink
LP
Low Profile (Riser)
FH
Full Height (Riser)
DW
Double Wide (Xilinx FPGA accelerator)
The following table provides the processor and heat sink matrix:
Table 17. Processor and heat sink matrixProcessor and heat sink matrix.
Heat sink
Processor TDP
2U HPR HSK
For all processor TDP
The following table provides the thermal restriction matrix:
T4 GPU card is supported on riser 2 (R2a slot 3/6) with maximum power loading.
Only ASHRAE A2 category ambient temperature is supported.
For all memory configurations, only HPR GOLD fan with 2U HPR HSK is used.
128 GB LRDIMM, 64 GB RDIMM, 32 GB RDIMM, and 16 GB RDIMM support at 35°C (95°F) ambient temperature.
Particulate and gaseous contamination specifications
If the levels of particulate or gaseous pollution exceed the specified limitations and result in equipment damage or failure, you must rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer. The following table defines the limitations that help avoid any equipment damage or failure from particulate and gaseous contamination:
Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit.
The ISO Class 8 condition applies to data center environments only. This air filtration requirement does not apply to IT equipment designed to be used outside a data center. For example, the requirement does not apply in environments such as an office or factory floor.
Air entering the data center must have MERV11 or MERV13 filtration.
Conductive dust
Air must be free of conductive dust, zinc whiskers, or other conductive particles.
This condition applies to data center and nondata center environments.
Corrosive dust
Air must be free of corrosive dust.
Residual dust present in the air must have a deliquescent point less than 60% relative humidity.
This condition applies to data center and nondata center environments.
The following table provides the gaseous contamination specifications: