iDRAC Quick Sync 2 module (optional) is on the left control panel of the system.
iDRAC Quick Sync 2 indicator code | Condition | Corrective action |
---|---|---|
Off (default state) | iDRAC Quick Sync 2 feature is powered off. Press the iDRAC Quick Sync 2 button to power on the iDRAC Quick Sync 2 feature. | If the LED fails to power on, reseat the left control panel flex cable and check. If the problem persists, see Dell Technologies Support. |
Solid white | iDRAC Quick Sync 2 is ready to communicate. Press the iDRAC Quick Sync 2 button to power off. | If the LED fails to power off, restart the system. If the problem persists, see Dell Technologies Support. |
Blinks white rapidly | Data transfer activity. | If the indicator blinks indefinitely, see Dell Technologies Support. |
Blinks white slowly | A firmware update is in progress. | If the indicator blinks indefinitely, see Dell Technologies Support. |
Blinks white five times rapidly and then powers off | iDRAC Quick Sync 2 feature is disabled. | Check if the iDRAC Quick Sync 2 feature is disabled by iDRAC. If the problem persists, see Dell Technologies Support. Dell PowerEdge manuals or the Dell OpenManage Server Administrator User’s Guide. |
Solid amber | The system is in fail-safe mode. | Restart the system. If the problem persists, see Dell Technologies Support. |
Blinking amber | iDRAC Quick Sync 2 hardware is not responding properly. | Restart the system. If the problem persists, see Dell Technologies Support. |