Dell PowerFlex Appliance with PowerFlex 4.x Administration Guide

Verify newly added storage data server is reflecting under the appropriate cluster

Use this procedure to verify that the newly added storage data server is reflecting under the storage data server cluster.

Steps

  1. Log in to the primary MDM using the following command:
    scli --login --username admin --management_system_ip <PFMP-UI IP> --password <PFMP-UI password> --insecure
  2. Run the following command to identify that the newly added PowerFlex node is reflecting under the storage data server
    scli –query_all_SDS
  3. Execute the following command to capture the protection domain and storage pool name:
    scli --query_all_volumes
  4. If the storage data server is missing from the storage data server cluster, use the following command to add the storage data server:
    scli --add_sds --sds_ip <data1 IPaddress, data2 IPaddress> --protection_domain_name <PD name> --storage_pool_name <spname> --disable_rmcache --sds_name <SDS-name>
  5. Add the device for the newly added storage data server:
    scli --add_sds_device --sds_name <newly add SDS name> --storage_pool_name <SP-name> --device_path <device path>
  6. Using SSH, log in to the PowerFlex node and run the lsblk command to identify the device path.